Effect of high temperature corrosion on austenitic stainless steel grade 304 in CO2 gas at 700ºC

Austenitic stainless steels of grade 304 were exposed to dry (Ar-75%CO2) and wet (Ar-75%CO2-12%H2O) environments at 700oC. This experimental setup involved horizontal tube furnace connected to CO2 gas and water vapour facilities. X-ray diffraction (XRD) technique, variable pressure-scanning electron...

Full description

Bibliographic Details
Main Authors: Nurul Atikah Shariff, Azman Jalar, Muhamad Izhar Sahri, Norinsan Kamil Othman
Format: Article
Language:English
Published: Universiti Kebangsaan Malaysia 2014
Online Access:http://journalarticle.ukm.my/7263/
http://journalarticle.ukm.my/7263/
http://journalarticle.ukm.my/7263/1/14_Nurul_Atikah.pdf