Development and validation of analytical method by RP-HPLC for quantification of Alpha-Mangostin Encapsulated in PLGA microspheres

A simple, rapid, precise and highly accurate RP-HPLC method was developed and validated for determination of alpha-mangostin content extracted from PLGA-microspheres. Method was developed using a silica-based deactivated C-18 column (4.6×100 mm, 3 μm) with a mobile phase of 70-80 % v/v acetonitril...

Full description

Bibliographic Details
Main Authors: Elsaid Ali, Aimen Abdo, Muhammad, Taher, Helaluddin , Abul Bashar Mohammed, Mohamed, Farahidah
Format: Article
Language:English
Published: OMICS Publishing Group 2012
Subjects:
Online Access:http://irep.iium.edu.my/30074/
http://irep.iium.edu.my/30074/
http://irep.iium.edu.my/30074/
http://irep.iium.edu.my/30074/1/Development_and_validation_of_analyticcal_method_by_RP-HPLC_for_quantification.pdf