Optimum Performance Improvements of the Combined Cycle Based on an Intercooler–Reheated Gas Turbine

The performance enhancements and modeling of the gas turbine (GT), together with the combined cycle gas turbine (CCGT) power plant, are described in this study. The thermal analysis has proposed intercooler–reheated-GT (IHGT) configuration of the CCGT system, as well as the development of a simulat...

Full description

Bibliographic Details
Main Authors: Thamir K., Ibrahim, M. M., Rahman
Format: Article
Language:English
Published: American Society of Mechanical Engineers (ASME) 2015
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/9346/
http://umpir.ump.edu.my/id/eprint/9346/
http://umpir.ump.edu.my/id/eprint/9346/
http://umpir.ump.edu.my/id/eprint/9346/1/fkm-2015-mmrahman-Optimum%20Performance%20Improvements.pdf
id ump-9346
recordtype eprints
spelling ump-93462018-01-30T02:36:36Z http://umpir.ump.edu.my/id/eprint/9346/ Optimum Performance Improvements of the Combined Cycle Based on an Intercooler–Reheated Gas Turbine Thamir K., Ibrahim M. M., Rahman TJ Mechanical engineering and machinery The performance enhancements and modeling of the gas turbine (GT), together with the combined cycle gas turbine (CCGT) power plant, are described in this study. The thermal analysis has proposed intercooler–reheated-GT (IHGT) configuration of the CCGT system, as well as the development of a simulation code and integrated model for exploiting the CCGT power plants performance, using the MATLAB code. The validation of a heavy-duty CCGT power plants performance is done through real power plants, namely, MARAFIQ CCGT plants in Saudi Arabia with satisfactory results. The results from this simulation show that the higher thermal efficiency of 56% MW, while high power output of 1640 MW, occurred in IHGT combined cycle plants (IHGTCC), having an optimal turbine inlet temperature about 1900 K. Furthermore, the CCGT system proposed in the study has improved power output by 94%. The results of optimization show that the IHGTCC has optimum power of 1860 MW and thermal efficiency of 59%. Therefore, the ambient temperatures and operation conditions of the CCGT strongly affect their performance. The optimum level of power and efficiency is seen at high turbine inlet temperatures and isentropic turbine efficiency. Thus, it can be understood that the models developed in this study are useful tools for estimating the CCGT power plant’s performance American Society of Mechanical Engineers (ASME) 2015 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/9346/1/fkm-2015-mmrahman-Optimum%20Performance%20Improvements.pdf Thamir K., Ibrahim and M. M., Rahman (2015) Optimum Performance Improvements of the Combined Cycle Based on an Intercooler–Reheated Gas Turbine. Journal of Energy Resources Technology, 137. pp. 1-11. ISSN 0195-0738 (print); 1528-8994 (online) http://dx.doi.org/10.1115/1.4030447 DOI: 10.1115/1.4030447
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Thamir K., Ibrahim
M. M., Rahman
Optimum Performance Improvements of the Combined Cycle Based on an Intercooler–Reheated Gas Turbine
description The performance enhancements and modeling of the gas turbine (GT), together with the combined cycle gas turbine (CCGT) power plant, are described in this study. The thermal analysis has proposed intercooler–reheated-GT (IHGT) configuration of the CCGT system, as well as the development of a simulation code and integrated model for exploiting the CCGT power plants performance, using the MATLAB code. The validation of a heavy-duty CCGT power plants performance is done through real power plants, namely, MARAFIQ CCGT plants in Saudi Arabia with satisfactory results. The results from this simulation show that the higher thermal efficiency of 56% MW, while high power output of 1640 MW, occurred in IHGT combined cycle plants (IHGTCC), having an optimal turbine inlet temperature about 1900 K. Furthermore, the CCGT system proposed in the study has improved power output by 94%. The results of optimization show that the IHGTCC has optimum power of 1860 MW and thermal efficiency of 59%. Therefore, the ambient temperatures and operation conditions of the CCGT strongly affect their performance. The optimum level of power and efficiency is seen at high turbine inlet temperatures and isentropic turbine efficiency. Thus, it can be understood that the models developed in this study are useful tools for estimating the CCGT power plant’s performance
format Article
author Thamir K., Ibrahim
M. M., Rahman
author_facet Thamir K., Ibrahim
M. M., Rahman
author_sort Thamir K., Ibrahim
title Optimum Performance Improvements of the Combined Cycle Based on an Intercooler–Reheated Gas Turbine
title_short Optimum Performance Improvements of the Combined Cycle Based on an Intercooler–Reheated Gas Turbine
title_full Optimum Performance Improvements of the Combined Cycle Based on an Intercooler–Reheated Gas Turbine
title_fullStr Optimum Performance Improvements of the Combined Cycle Based on an Intercooler–Reheated Gas Turbine
title_full_unstemmed Optimum Performance Improvements of the Combined Cycle Based on an Intercooler–Reheated Gas Turbine
title_sort optimum performance improvements of the combined cycle based on an intercooler–reheated gas turbine
publisher American Society of Mechanical Engineers (ASME)
publishDate 2015
url http://umpir.ump.edu.my/id/eprint/9346/
http://umpir.ump.edu.my/id/eprint/9346/
http://umpir.ump.edu.my/id/eprint/9346/
http://umpir.ump.edu.my/id/eprint/9346/1/fkm-2015-mmrahman-Optimum%20Performance%20Improvements.pdf
first_indexed 2023-09-18T22:07:50Z
last_indexed 2023-09-18T22:07:50Z
_version_ 1777414827045552128