Non-invasive Process Tomography in Chemical Mixtures – A Review
Decades of research, visualizing and monitoring chemical mixtures in the process plant non-invasively plays an important role in making sure that the system produces a high quality product without disturbing the nature of the plant. In this case, process tomography can be applied for the chemical mi...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier Ltd
2015
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/9117/ http://umpir.ump.edu.my/id/eprint/9117/ http://umpir.ump.edu.my/id/eprint/9117/ http://umpir.ump.edu.my/id/eprint/9117/1/fkee-2015-yasmin-Non-Invasive.pdf |
id |
ump-9117 |
---|---|
recordtype |
eprints |
spelling |
ump-91172018-02-14T01:56:07Z http://umpir.ump.edu.my/id/eprint/9117/ Non-invasive Process Tomography in Chemical Mixtures – A Review Yasmin, Abdul Wahab Ruzairi, Abdul Rahim Mohd Hafiz, Fazalul Rahiman Suzanna, Ridzuan Aw Fazlul Rahman, Mohd Yunus Chiew, Loon Goh Herlina, Abdul Rahim Leow, Pei Ling TK Electrical engineering. Electronics Nuclear engineering Decades of research, visualizing and monitoring chemical mixtures in the process plant non-invasively plays an important role in making sure that the system produces a high quality product without disturbing the nature of the plant. In this case, process tomography can be applied for the chemical mixtures. Thus, the objective of this paper is to review the current research on non-invasive process tomography for detecting chemical mixtures based on hard-field and soft-field tomography. The discussion on liquid–liquid, liquid–solid and liquid–gas two-phase flow for every type of non-invasive process tomography is explained in detail. Consequently, non-invasive process tomography has expanded strongly in chemical applications. Finally, potential future research on the chemical mixture based on ERT is addressed. Elsevier Ltd 2015 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/9117/1/fkee-2015-yasmin-Non-Invasive.pdf Yasmin, Abdul Wahab and Ruzairi, Abdul Rahim and Mohd Hafiz, Fazalul Rahiman and Suzanna, Ridzuan Aw and Fazlul Rahman, Mohd Yunus and Chiew, Loon Goh and Herlina, Abdul Rahim and Leow, Pei Ling (2015) Non-invasive Process Tomography in Chemical Mixtures – A Review. Sensors and Actuators B: Chemical, 210. pp. 602-617. ISSN 0925-4005 http://dx.doi.org/10.1016/j.snb.2014.12.103 DOI: 10.1016/j.snb.2014.12.103 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Yasmin, Abdul Wahab Ruzairi, Abdul Rahim Mohd Hafiz, Fazalul Rahiman Suzanna, Ridzuan Aw Fazlul Rahman, Mohd Yunus Chiew, Loon Goh Herlina, Abdul Rahim Leow, Pei Ling Non-invasive Process Tomography in Chemical Mixtures – A Review |
description |
Decades of research, visualizing and monitoring chemical mixtures in the process plant non-invasively plays an important role in making sure that the system produces a high quality product without disturbing the nature of the plant. In this case, process tomography can be applied for the chemical mixtures. Thus, the objective of this paper is to review the current research on non-invasive process tomography for detecting chemical mixtures based on hard-field and soft-field tomography. The discussion on liquid–liquid, liquid–solid and liquid–gas two-phase flow for every type of non-invasive process tomography is explained in detail. Consequently, non-invasive process tomography has expanded strongly in chemical applications. Finally, potential future research on the chemical mixture based on ERT is addressed. |
format |
Article |
author |
Yasmin, Abdul Wahab Ruzairi, Abdul Rahim Mohd Hafiz, Fazalul Rahiman Suzanna, Ridzuan Aw Fazlul Rahman, Mohd Yunus Chiew, Loon Goh Herlina, Abdul Rahim Leow, Pei Ling |
author_facet |
Yasmin, Abdul Wahab Ruzairi, Abdul Rahim Mohd Hafiz, Fazalul Rahiman Suzanna, Ridzuan Aw Fazlul Rahman, Mohd Yunus Chiew, Loon Goh Herlina, Abdul Rahim Leow, Pei Ling |
author_sort |
Yasmin, Abdul Wahab |
title |
Non-invasive Process Tomography in Chemical Mixtures – A Review |
title_short |
Non-invasive Process Tomography in Chemical Mixtures – A Review |
title_full |
Non-invasive Process Tomography in Chemical Mixtures – A Review |
title_fullStr |
Non-invasive Process Tomography in Chemical Mixtures – A Review |
title_full_unstemmed |
Non-invasive Process Tomography in Chemical Mixtures – A Review |
title_sort |
non-invasive process tomography in chemical mixtures – a review |
publisher |
Elsevier Ltd |
publishDate |
2015 |
url |
http://umpir.ump.edu.my/id/eprint/9117/ http://umpir.ump.edu.my/id/eprint/9117/ http://umpir.ump.edu.my/id/eprint/9117/ http://umpir.ump.edu.my/id/eprint/9117/1/fkee-2015-yasmin-Non-Invasive.pdf |
first_indexed |
2023-09-18T22:07:20Z |
last_indexed |
2023-09-18T22:07:20Z |
_version_ |
1777414796479561728 |