Effect of the time taken on the performance of fabricated gas–solid fluidized bed column for the separation of rare earth elements
A gas–solid fluidized bed separator used for the separation of rare earth elements (REEs) from printed circuit board was design and fabricated. In this work, the effect of time taken on the performance of the fabricated gas-solid fluidized bed column for the separation of rare earth elements was stu...
Main Author: | |
---|---|
Format: | Undergraduates Project Papers |
Language: | English |
Published: |
2014
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/8989/ http://umpir.ump.edu.my/id/eprint/8989/ http://umpir.ump.edu.my/id/eprint/8989/1/CD8649%20%40%2052.pdf |
id |
ump-8989 |
---|---|
recordtype |
eprints |
spelling |
ump-89892015-10-23T07:25:20Z http://umpir.ump.edu.my/id/eprint/8989/ Effect of the time taken on the performance of fabricated gas–solid fluidized bed column for the separation of rare earth elements Nik Syahira, Nik Alias TP Chemical technology A gas–solid fluidized bed separator used for the separation of rare earth elements (REEs) from printed circuit board was design and fabricated. In this work, the effect of time taken on the performance of the fabricated gas-solid fluidized bed column for the separation of rare earth elements was study. Waste from electronic devices was grinded to powder forms with the particles sized less than 1.0 μm were used in this study. Beds column with different heights of sampling port were analyzed at 10 cm, 20 cm, and 30 cm while the air pressure was 15 psi, 20 psi and 25 psi were tried in this investigation. The rare earth elements were subsequently analyzed by float–sink testing. The results showed the weight percent of the fine powder increases with increasing the time taken for collecting the sample. However, the separation density decreased with increasing the sampling port height of the column 2014-07 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/8989/1/CD8649%20%40%2052.pdf Nik Syahira, Nik Alias (2014) Effect of the time taken on the performance of fabricated gas–solid fluidized bed column for the separation of rare earth elements. Faculty Of Chemical & Natural Resources Engineering, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:84608&theme=UMP2 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
TP Chemical technology |
spellingShingle |
TP Chemical technology Nik Syahira, Nik Alias Effect of the time taken on the performance of fabricated gas–solid fluidized bed column for the separation of rare earth elements |
description |
A gas–solid fluidized bed separator used for the separation of rare earth elements (REEs) from printed circuit board was design and fabricated. In this work, the effect of time taken on the performance of the fabricated gas-solid fluidized bed column for the separation of rare earth elements was study. Waste from electronic devices was grinded to powder forms with the particles sized less than 1.0 μm were used in this study. Beds column with different heights of sampling port were analyzed at 10 cm, 20 cm, and 30 cm while the air pressure was 15 psi, 20 psi and 25 psi were tried in this investigation. The rare earth elements were subsequently analyzed by float–sink testing. The results showed the weight percent of the fine powder increases with increasing the time taken for collecting the sample. However, the separation density decreased with increasing the sampling port height of the column |
format |
Undergraduates Project Papers |
author |
Nik Syahira, Nik Alias |
author_facet |
Nik Syahira, Nik Alias |
author_sort |
Nik Syahira, Nik Alias |
title |
Effect of the time taken on the performance of fabricated gas–solid fluidized bed column for the separation of rare earth elements |
title_short |
Effect of the time taken on the performance of fabricated gas–solid fluidized bed column for the separation of rare earth elements |
title_full |
Effect of the time taken on the performance of fabricated gas–solid fluidized bed column for the separation of rare earth elements |
title_fullStr |
Effect of the time taken on the performance of fabricated gas–solid fluidized bed column for the separation of rare earth elements |
title_full_unstemmed |
Effect of the time taken on the performance of fabricated gas–solid fluidized bed column for the separation of rare earth elements |
title_sort |
effect of the time taken on the performance of fabricated gas–solid fluidized bed column for the separation of rare earth elements |
publishDate |
2014 |
url |
http://umpir.ump.edu.my/id/eprint/8989/ http://umpir.ump.edu.my/id/eprint/8989/ http://umpir.ump.edu.my/id/eprint/8989/1/CD8649%20%40%2052.pdf |
first_indexed |
2023-09-18T22:07:04Z |
last_indexed |
2023-09-18T22:07:04Z |
_version_ |
1777414778825736192 |