Analysis on the performances of a micro gas turbine cogeneration system in sewage treatment plants

The main role of this study is to analyse the economics performances of micro gas turbine co-generation systems (MGT-CGSs) in order to define the most interesting solutions from economic point of view. The study consist two type of economic analysis, simple and advanced economic analysis. The simple...

Full description

Bibliographic Details
Main Author: Muhammad Zaid, Nor Azlan
Format: Undergraduates Project Papers
Language:English
Published: 2013
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/8683/
http://umpir.ump.edu.my/id/eprint/8683/
http://umpir.ump.edu.my/id/eprint/8683/1/cd8242.pdf
id ump-8683
recordtype eprints
spelling ump-86832015-10-29T00:02:57Z http://umpir.ump.edu.my/id/eprint/8683/ Analysis on the performances of a micro gas turbine cogeneration system in sewage treatment plants Muhammad Zaid, Nor Azlan TJ Mechanical engineering and machinery The main role of this study is to analyse the economics performances of micro gas turbine co-generation systems (MGT-CGSs) in order to define the most interesting solutions from economic point of view. The study consist two type of economic analysis, simple and advanced economic analysis. The simple economic analysis is analysis based on the present and previous data collected that no estimation needed. The advanced economic analysis is the analysis that need to consider the estimation for the future value or parameter. The advanced economic analysis give better over view of the economic analysis of the system. Considering operation of the MGT-CGS under various loads and efficiency of the MGT-CGSs under partial road condition, the optimal combination of MGT-CGS (MGT-combination) with different sizes, 30 kW, 65 kW and 200 kW. Economic performance of MGT-CGSs under three typical ambient temperature conditions and three different scale sewage treatment plant was also investigated. It was found that MGT combination has the highest total capital cost for every scale and every temperature condition. Futhermore MGT combination has the highest total electricity sold. Excluding MGT combination total electricity sold higher when the MGT power output higher. 2013-06 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/8683/1/cd8242.pdf Muhammad Zaid, Nor Azlan (2013) Analysis on the performances of a micro gas turbine cogeneration system in sewage treatment plants. Faculty of Mechanical Engineering, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:82399&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Muhammad Zaid, Nor Azlan
Analysis on the performances of a micro gas turbine cogeneration system in sewage treatment plants
description The main role of this study is to analyse the economics performances of micro gas turbine co-generation systems (MGT-CGSs) in order to define the most interesting solutions from economic point of view. The study consist two type of economic analysis, simple and advanced economic analysis. The simple economic analysis is analysis based on the present and previous data collected that no estimation needed. The advanced economic analysis is the analysis that need to consider the estimation for the future value or parameter. The advanced economic analysis give better over view of the economic analysis of the system. Considering operation of the MGT-CGS under various loads and efficiency of the MGT-CGSs under partial road condition, the optimal combination of MGT-CGS (MGT-combination) with different sizes, 30 kW, 65 kW and 200 kW. Economic performance of MGT-CGSs under three typical ambient temperature conditions and three different scale sewage treatment plant was also investigated. It was found that MGT combination has the highest total capital cost for every scale and every temperature condition. Futhermore MGT combination has the highest total electricity sold. Excluding MGT combination total electricity sold higher when the MGT power output higher.
format Undergraduates Project Papers
author Muhammad Zaid, Nor Azlan
author_facet Muhammad Zaid, Nor Azlan
author_sort Muhammad Zaid, Nor Azlan
title Analysis on the performances of a micro gas turbine cogeneration system in sewage treatment plants
title_short Analysis on the performances of a micro gas turbine cogeneration system in sewage treatment plants
title_full Analysis on the performances of a micro gas turbine cogeneration system in sewage treatment plants
title_fullStr Analysis on the performances of a micro gas turbine cogeneration system in sewage treatment plants
title_full_unstemmed Analysis on the performances of a micro gas turbine cogeneration system in sewage treatment plants
title_sort analysis on the performances of a micro gas turbine cogeneration system in sewage treatment plants
publishDate 2013
url http://umpir.ump.edu.my/id/eprint/8683/
http://umpir.ump.edu.my/id/eprint/8683/
http://umpir.ump.edu.my/id/eprint/8683/1/cd8242.pdf
first_indexed 2023-09-18T22:06:31Z
last_indexed 2023-09-18T22:06:31Z
_version_ 1777414745015451648