Effect of Cooling and Isothermal Aging on Microstructure Using Electroless Nickel (Boron) Plating
This paper presents a study on relationship of cooling rates towards the intermetallic compound (IMC) morphology. Cooling rate is an important parameter as it has significant effect towards the IMC microstructure formation that indirectly affects solders joint reliability. However, there is still in...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
scientific.net
2015
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/8576/ http://umpir.ump.edu.my/id/eprint/8576/ http://umpir.ump.edu.my/id/eprint/8576/1/Effect%20of%20Cooling%20and%20Isothermal%20Aging%20on%20Microstructure%20Using%20Electroless%20Nickel%20%28Boron%29%20Plating.pdf |
id |
ump-8576 |
---|---|
recordtype |
eprints |
spelling |
ump-85762018-01-15T06:58:19Z http://umpir.ump.edu.my/id/eprint/8576/ Effect of Cooling and Isothermal Aging on Microstructure Using Electroless Nickel (Boron) Plating Hardinnawirda, Kahar Zetty Akhtar, Abd Malek Siti Rabiatull Aisha, Idris M., Ishak TJ Mechanical engineering and machinery This paper presents a study on relationship of cooling rates towards the intermetallic compound (IMC) morphology. Cooling rate is an important parameter as it has significant effect towards the IMC microstructure formation that indirectly affects solders joint reliability. However, there is still insufficient study regarding the effect of cooling rate on the IMC thickness and microstructure behavior by using Nickel Boron as surface finish material in the electronic packaging industry. In this study, Sn-3Ag-0.5Cu solder was used on Nickel Boron as coating layer. Cooling rates were obtained by cooling specimens in different media which is water and air. The elemental composition was confirmed using Energy-dispersive X-ray spectroscopy and the microstructure of each IMC then analyzed using optical microscope, image analyzer and ImageJ. In this study, faster cooling rate (water) found to provide thicker IMC (6μm) compared to the other medium used. The morphology shape of each IMC also differs between different medium of cooling. IMC that undergoes faster cooling showed continues like layer while the one using air cooling formed scallop scientific.net 2015 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/8576/1/Effect%20of%20Cooling%20and%20Isothermal%20Aging%20on%20Microstructure%20Using%20Electroless%20Nickel%20%28Boron%29%20Plating.pdf Hardinnawirda, Kahar and Zetty Akhtar, Abd Malek and Siti Rabiatull Aisha, Idris and M., Ishak (2015) Effect of Cooling and Isothermal Aging on Microstructure Using Electroless Nickel (Boron) Plating. Applied Mechanics and Materials, 695. pp. 352-356. ISSN 1662-7482 http://www.scientific.net/AMM.695.352 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Hardinnawirda, Kahar Zetty Akhtar, Abd Malek Siti Rabiatull Aisha, Idris M., Ishak Effect of Cooling and Isothermal Aging on Microstructure Using Electroless Nickel (Boron) Plating |
description |
This paper presents a study on relationship of cooling rates towards the intermetallic compound (IMC) morphology. Cooling rate is an important parameter as it has significant effect towards the IMC microstructure formation that indirectly affects solders joint reliability. However, there is still insufficient study regarding the effect of cooling rate on the IMC thickness and microstructure behavior by using Nickel Boron as surface finish material in the electronic packaging industry. In this study, Sn-3Ag-0.5Cu solder was used on Nickel Boron as coating layer. Cooling rates were obtained by cooling specimens in different media which is water and air. The elemental composition was confirmed using Energy-dispersive X-ray spectroscopy and the microstructure of each IMC then analyzed using optical microscope, image analyzer and ImageJ. In this study, faster cooling rate (water) found to provide thicker IMC (6μm) compared to the other medium used. The morphology shape of each IMC also differs between different medium of cooling. IMC that undergoes faster cooling showed continues like layer while the one using air cooling formed scallop |
format |
Article |
author |
Hardinnawirda, Kahar Zetty Akhtar, Abd Malek Siti Rabiatull Aisha, Idris M., Ishak |
author_facet |
Hardinnawirda, Kahar Zetty Akhtar, Abd Malek Siti Rabiatull Aisha, Idris M., Ishak |
author_sort |
Hardinnawirda, Kahar |
title |
Effect of Cooling and Isothermal Aging on Microstructure Using Electroless Nickel (Boron) Plating |
title_short |
Effect of Cooling and Isothermal Aging on Microstructure Using Electroless Nickel (Boron) Plating |
title_full |
Effect of Cooling and Isothermal Aging on Microstructure Using Electroless Nickel (Boron) Plating |
title_fullStr |
Effect of Cooling and Isothermal Aging on Microstructure Using Electroless Nickel (Boron) Plating |
title_full_unstemmed |
Effect of Cooling and Isothermal Aging on Microstructure Using Electroless Nickel (Boron) Plating |
title_sort |
effect of cooling and isothermal aging on microstructure using electroless nickel (boron) plating |
publisher |
scientific.net |
publishDate |
2015 |
url |
http://umpir.ump.edu.my/id/eprint/8576/ http://umpir.ump.edu.my/id/eprint/8576/ http://umpir.ump.edu.my/id/eprint/8576/1/Effect%20of%20Cooling%20and%20Isothermal%20Aging%20on%20Microstructure%20Using%20Electroless%20Nickel%20%28Boron%29%20Plating.pdf |
first_indexed |
2023-09-18T22:06:18Z |
last_indexed |
2023-09-18T22:06:18Z |
_version_ |
1777414730775789568 |