Design and Development of Gas Leakage Monitoring System
Gas leakage in industrial area causes many health issues. Thus, to prevent such disasters happen, the atmosphere of a workplace should be regularly monitored and controlled, in order to maintain the clean air environment. However, efforts in industrial air quality control have been impeded by the la...
Main Authors: | , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2014
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/8365/ http://umpir.ump.edu.my/id/eprint/8365/ http://umpir.ump.edu.my/id/eprint/8365/1/Design_and_Development_of_Gas_Leakage_Monitoring_System.pdf |
id |
ump-8365 |
---|---|
recordtype |
eprints |
spelling |
ump-83652018-04-19T01:27:00Z http://umpir.ump.edu.my/id/eprint/8365/ Design and Development of Gas Leakage Monitoring System Huan, Hui Yan Yusnita, Rahayu TK Electrical engineering. Electronics Nuclear engineering Gas leakage in industrial area causes many health issues. Thus, to prevent such disasters happen, the atmosphere of a workplace should be regularly monitored and controlled, in order to maintain the clean air environment. However, efforts in industrial air quality control have been impeded by the lack of science-based approaches to identify and assess atmosphere air quality and level of dangerous gas. Therefore, a monitoring system for gas leakage detection needs to be developed. For the development of this system, the combustible gas sensor (MQ9) was used in order to detect the present of methane (CH4) and carbon monoxide gas (CO). This sensor will detect the concentration of the gas according to the voltage output of sensor and operated in the alarm system, autonomous control system and monitoring system by using Arduino uno as the microcontroller for the whole system. Whereas the Zigbee will send the data reading from the gas sensor to monitoring system that display on LabVIEW Graphical User Interface (GUI). Besides, user can take immediate action upon the leakage occurs, else the gas supply and the system will shut down automatically within 10 minutes to prevent the condition becoming worst. 2014 Conference or Workshop Item PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/8365/1/Design_and_Development_of_Gas_Leakage_Monitoring_System.pdf Huan, Hui Yan and Yusnita, Rahayu (2014) Design and Development of Gas Leakage Monitoring System. In: Proceeding of International Conference on Electrical Engineering, Computer Science and Informatics (EECSI 2014), 20-21 August 2014 , Yogyakarta, Indonesia. pp. 207-212.. http://portalgaruda.org/portalgaruda/journals/index.php/EECSI/article/view/404 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Huan, Hui Yan Yusnita, Rahayu Design and Development of Gas Leakage Monitoring System |
description |
Gas leakage in industrial area causes many health issues. Thus, to prevent such disasters happen, the atmosphere of a workplace should be regularly monitored and controlled, in order to maintain the clean air environment. However, efforts in industrial air quality control have been impeded by the lack of science-based approaches to identify and assess atmosphere air quality and level of dangerous gas. Therefore, a monitoring system for gas leakage detection needs to be developed. For the development of this system, the combustible gas sensor (MQ9) was used in order to detect the present of methane (CH4) and carbon monoxide gas (CO). This sensor will detect the concentration of the gas according to the voltage output of sensor and operated in the alarm system, autonomous control system and monitoring system by using Arduino uno as the microcontroller for the whole system. Whereas the Zigbee will send the data reading from the gas sensor to monitoring system that display on LabVIEW Graphical User Interface (GUI). Besides, user can take immediate action upon the leakage occurs, else the gas supply and the system will shut down automatically within 10 minutes to prevent the condition becoming worst. |
format |
Conference or Workshop Item |
author |
Huan, Hui Yan Yusnita, Rahayu |
author_facet |
Huan, Hui Yan Yusnita, Rahayu |
author_sort |
Huan, Hui Yan |
title |
Design and Development of Gas Leakage Monitoring System |
title_short |
Design and Development of Gas Leakage Monitoring System |
title_full |
Design and Development of Gas Leakage Monitoring System |
title_fullStr |
Design and Development of Gas Leakage Monitoring System |
title_full_unstemmed |
Design and Development of Gas Leakage Monitoring System |
title_sort |
design and development of gas leakage monitoring system |
publishDate |
2014 |
url |
http://umpir.ump.edu.my/id/eprint/8365/ http://umpir.ump.edu.my/id/eprint/8365/ http://umpir.ump.edu.my/id/eprint/8365/1/Design_and_Development_of_Gas_Leakage_Monitoring_System.pdf |
first_indexed |
2023-09-18T22:05:51Z |
last_indexed |
2023-09-18T22:05:51Z |
_version_ |
1777414703065071616 |