Leak detection in pipelines using wavelet and cepstrum analysis

Nowadays, piping system is one of the important features in either home of industrial user. It is essential for transporting fluid from a point to another point. But due to many reasons, leaks may occur in the pipelines. This research is focusing on detecting and locating the leaks in the pipeline a...

Full description

Bibliographic Details
Main Author: Abdul Kadir, Samta
Format: Undergraduates Project Papers
Language:English
English
English
English
Published: 2013
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/8345/
http://umpir.ump.edu.my/id/eprint/8345/
http://umpir.ump.edu.my/id/eprint/8345/1/Leak%20detection%20in%20pipelines%20using%20wavelet%20and%20cepstrum%20analysis%20-%20Table%20of%20content.pdf
http://umpir.ump.edu.my/id/eprint/8345/2/Leak%20detection%20in%20pipelines%20using%20wavelet%20and%20cepstrum%20analysis%20-%20Abstract.pdf
http://umpir.ump.edu.my/id/eprint/8345/3/Leak%20detection%20in%20pipelines%20using%20wavelet%20and%20cepstrum%20analysis%20-%20Chapter%201.pdf
http://umpir.ump.edu.my/id/eprint/8345/4/Leak%20detection%20in%20pipelines%20using%20wavelet%20and%20cepstrum%20analysis%20-%20References.pdf
id ump-8345
recordtype eprints
spelling ump-83452017-04-04T05:34:48Z http://umpir.ump.edu.my/id/eprint/8345/ Leak detection in pipelines using wavelet and cepstrum analysis Abdul Kadir, Samta TA Engineering (General). Civil engineering (General) Nowadays, piping system is one of the important features in either home of industrial user. It is essential for transporting fluid from a point to another point. But due to many reasons, leaks may occur in the pipelines. This research is focusing on detecting and locating the leaks in the pipeline and to successfully complete the research signal analysis of wavelet and cepstrum analysis is used. This research proposed a technique which is transient method. The basic principle is the fact that water spouting out of a leak in a pressurized pipe generates signal, and this signal contains information to whether a leak exists and where it is located. The present transient methods for finding leaks are mainly based upon correlation analysis, where one sensing device is installed at each side of a leak. This method is hard to operate because it needs a lot of operators to operate it due to equipment in different place. So to overcome this limitation, this research project proposed a new method by using just one sensing device which means all of the equipment in one place. This method use pressure transducer as the sensing device. This will make the method more friendly user and reduce the cost of operators. The results predict satisfactorily the leak location as the error between analyzed data and measured data is from 0.81% to 4.26%. This report starts with the introduction section to outline on the backgroundn and purpose of the study. It continues with the literature section that explains theleakage detection techniques, wave propagation and signal processing. The experimental part involves fabricating the pipe system using high density polyethylene and galvanized iron pipe. Subsequently signal processing section covers analysis of data and final results. 2013-06 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/8345/1/Leak%20detection%20in%20pipelines%20using%20wavelet%20and%20cepstrum%20analysis%20-%20Table%20of%20content.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/8345/2/Leak%20detection%20in%20pipelines%20using%20wavelet%20and%20cepstrum%20analysis%20-%20Abstract.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/8345/3/Leak%20detection%20in%20pipelines%20using%20wavelet%20and%20cepstrum%20analysis%20-%20Chapter%201.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/8345/4/Leak%20detection%20in%20pipelines%20using%20wavelet%20and%20cepstrum%20analysis%20-%20References.pdf Abdul Kadir, Samta (2013) Leak detection in pipelines using wavelet and cepstrum analysis. Faculty of Mechanical Engineering, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:82427&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
English
English
English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Abdul Kadir, Samta
Leak detection in pipelines using wavelet and cepstrum analysis
description Nowadays, piping system is one of the important features in either home of industrial user. It is essential for transporting fluid from a point to another point. But due to many reasons, leaks may occur in the pipelines. This research is focusing on detecting and locating the leaks in the pipeline and to successfully complete the research signal analysis of wavelet and cepstrum analysis is used. This research proposed a technique which is transient method. The basic principle is the fact that water spouting out of a leak in a pressurized pipe generates signal, and this signal contains information to whether a leak exists and where it is located. The present transient methods for finding leaks are mainly based upon correlation analysis, where one sensing device is installed at each side of a leak. This method is hard to operate because it needs a lot of operators to operate it due to equipment in different place. So to overcome this limitation, this research project proposed a new method by using just one sensing device which means all of the equipment in one place. This method use pressure transducer as the sensing device. This will make the method more friendly user and reduce the cost of operators. The results predict satisfactorily the leak location as the error between analyzed data and measured data is from 0.81% to 4.26%. This report starts with the introduction section to outline on the backgroundn and purpose of the study. It continues with the literature section that explains theleakage detection techniques, wave propagation and signal processing. The experimental part involves fabricating the pipe system using high density polyethylene and galvanized iron pipe. Subsequently signal processing section covers analysis of data and final results.
format Undergraduates Project Papers
author Abdul Kadir, Samta
author_facet Abdul Kadir, Samta
author_sort Abdul Kadir, Samta
title Leak detection in pipelines using wavelet and cepstrum analysis
title_short Leak detection in pipelines using wavelet and cepstrum analysis
title_full Leak detection in pipelines using wavelet and cepstrum analysis
title_fullStr Leak detection in pipelines using wavelet and cepstrum analysis
title_full_unstemmed Leak detection in pipelines using wavelet and cepstrum analysis
title_sort leak detection in pipelines using wavelet and cepstrum analysis
publishDate 2013
url http://umpir.ump.edu.my/id/eprint/8345/
http://umpir.ump.edu.my/id/eprint/8345/
http://umpir.ump.edu.my/id/eprint/8345/1/Leak%20detection%20in%20pipelines%20using%20wavelet%20and%20cepstrum%20analysis%20-%20Table%20of%20content.pdf
http://umpir.ump.edu.my/id/eprint/8345/2/Leak%20detection%20in%20pipelines%20using%20wavelet%20and%20cepstrum%20analysis%20-%20Abstract.pdf
http://umpir.ump.edu.my/id/eprint/8345/3/Leak%20detection%20in%20pipelines%20using%20wavelet%20and%20cepstrum%20analysis%20-%20Chapter%201.pdf
http://umpir.ump.edu.my/id/eprint/8345/4/Leak%20detection%20in%20pipelines%20using%20wavelet%20and%20cepstrum%20analysis%20-%20References.pdf
first_indexed 2023-09-18T22:05:49Z
last_indexed 2023-09-18T22:05:49Z
_version_ 1777414700361842688