Performance Characterization of a Vanadium Redox Flow Battery at Different Operating Parameters under a Standardized Test-Bed System
This paper describes the experimental characterization of a 25 cm2 laboratory scale vanadium redox flow battery (V-RFB). The unit cell performance with respect to voltage, coulombic and energy efficiencies under different performance parameters (current densities, operating temperatures, flow rates,...
Main Authors: | , , |
---|---|
Format: | Article |
Published: |
Elsevier
2015
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/7495/ http://umpir.ump.edu.my/id/eprint/7495/ http://umpir.ump.edu.my/id/eprint/7495/ |
id |
ump-7495 |
---|---|
recordtype |
eprints |
spelling |
ump-74952018-03-07T04:24:28Z http://umpir.ump.edu.my/id/eprint/7495/ Performance Characterization of a Vanadium Redox Flow Battery at Different Operating Parameters under a Standardized Test-Bed System Mohd Rusllim, Mohamed P. K., Leung M. H., Sulaiman TK Electrical engineering. Electronics Nuclear engineering QD Chemistry This paper describes the experimental characterization of a 25 cm2 laboratory scale vanadium redox flow battery (V-RFB). The unit cell performance with respect to voltage, coulombic and energy efficiencies under different performance parameters (current densities, operating temperatures, flow rates, electrolyte concentrations and material properties of 5 cm × 5 cm electrodes) are presented. The cell exhibits different characteristics under different operating parameters; the highest energy efficiency is recorded at c.a. 82%, operating at 308 K, 60 mA cm−2 and 3 cm3 s−1 volumetric flow rate for 250 cm3 electrolytes (each reservoir) of 1.6 mol dm−3V(III)/V(IV) in 4 mol dm−3 H2SO4. Formation charge of the mixture of vanadium species into single electro-active species at positive and negative electrodes are presented. Estimated time for the electro-active species to complete the formation charge using electrochemical calculation of Faraday’s constant are presented; a discrepancy of 4.5% is found between the theoretical and experimental data using current density of 80 mA cm−2. Elsevier 2015 Article PeerReviewed Mohd Rusllim, Mohamed and P. K., Leung and M. H., Sulaiman (2015) Performance Characterization of a Vanadium Redox Flow Battery at Different Operating Parameters under a Standardized Test-Bed System. Applied Energy, 137. pp. 402-412. ISSN 0306-2619 http://dx.doi.org/10.1016/j.apenergy.2014.10.042 DOI. 10.1016/j.apenergy.2014.10.042 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
topic |
TK Electrical engineering. Electronics Nuclear engineering QD Chemistry |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering QD Chemistry Mohd Rusllim, Mohamed P. K., Leung M. H., Sulaiman Performance Characterization of a Vanadium Redox Flow Battery at Different Operating Parameters under a Standardized Test-Bed System |
description |
This paper describes the experimental characterization of a 25 cm2 laboratory scale vanadium redox flow battery (V-RFB). The unit cell performance with respect to voltage, coulombic and energy efficiencies under different performance parameters (current densities, operating temperatures, flow rates, electrolyte concentrations and material properties of 5 cm × 5 cm electrodes) are presented. The cell exhibits different characteristics under different operating parameters; the highest energy efficiency is recorded at c.a. 82%, operating at 308 K, 60 mA cm−2 and 3 cm3 s−1 volumetric flow rate for 250 cm3 electrolytes (each reservoir) of 1.6 mol dm−3V(III)/V(IV) in 4 mol dm−3 H2SO4. Formation charge of the mixture of vanadium species into single electro-active species at positive and negative electrodes are presented. Estimated time for the electro-active species to complete the formation charge using electrochemical calculation of Faraday’s constant are presented; a discrepancy of 4.5% is found between the theoretical and experimental data using current density of 80 mA cm−2. |
format |
Article |
author |
Mohd Rusllim, Mohamed P. K., Leung M. H., Sulaiman |
author_facet |
Mohd Rusllim, Mohamed P. K., Leung M. H., Sulaiman |
author_sort |
Mohd Rusllim, Mohamed |
title |
Performance Characterization of a Vanadium Redox Flow Battery at Different Operating Parameters under a Standardized Test-Bed System |
title_short |
Performance Characterization of a Vanadium Redox Flow Battery at Different Operating Parameters under a Standardized Test-Bed System |
title_full |
Performance Characterization of a Vanadium Redox Flow Battery at Different Operating Parameters under a Standardized Test-Bed System |
title_fullStr |
Performance Characterization of a Vanadium Redox Flow Battery at Different Operating Parameters under a Standardized Test-Bed System |
title_full_unstemmed |
Performance Characterization of a Vanadium Redox Flow Battery at Different Operating Parameters under a Standardized Test-Bed System |
title_sort |
performance characterization of a vanadium redox flow battery at different operating parameters under a standardized test-bed system |
publisher |
Elsevier |
publishDate |
2015 |
url |
http://umpir.ump.edu.my/id/eprint/7495/ http://umpir.ump.edu.my/id/eprint/7495/ http://umpir.ump.edu.my/id/eprint/7495/ |
first_indexed |
2023-09-18T22:04:09Z |
last_indexed |
2023-09-18T22:04:09Z |
_version_ |
1777414595374219264 |