A DOAS System For Monitoring Of Ammonia Emission In The Agricultural Sector
Ammonia emission in the atmosphere is a major concern in EU countries. In 2005 it was reported by European Environmental Agency (EEA) that 93% of the EU15 countries come from agricultural sector. This paper reported an open-path differential optical absorption spectroscopy (DOAS) system to monitor a...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Elsevier Ltd
2014
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/6821/ http://umpir.ump.edu.my/id/eprint/6821/ http://umpir.ump.edu.my/id/eprint/6821/ http://umpir.ump.edu.my/id/eprint/6821/1/A_DOAS_System_For_Monitoring_Of_Ammonia_Emission_In_The_Agricultural_Sector.pdf http://umpir.ump.edu.my/id/eprint/6821/4/A%20DOAS%20System%20for%20Monitoring%20of%20Ammonia%20Emission%20in%20the%20Agricultural%20Sector.pdf |
id |
ump-6821 |
---|---|
recordtype |
eprints |
spelling |
ump-68212018-02-07T06:18:48Z http://umpir.ump.edu.my/id/eprint/6821/ A DOAS System For Monitoring Of Ammonia Emission In The Agricultural Sector Hadi, Manap M. S., Najib T Technology (General) Ammonia emission in the atmosphere is a major concern in EU countries. In 2005 it was reported by European Environmental Agency (EEA) that 93% of the EU15 countries come from agricultural sector. This paper reported an open-path differential optical absorption spectroscopy (DOAS) system to monitor ammonia emission in the agricultural sector. In the initial stage, analysis of the absorption lines for ammonia in the ultraviolet region was performed and the optimum wavelength for ammonia measurement was selected at 212 nm. A few tests were conducted to verify the detection system reliability and this DOAS system was able to detect various ammonia concentrations from 0 to 100 ppm. It is also shown that this DOAS system has better response and recovery time than a chemisorption sensor. In this paper, ammonia levels measurement in a cattle barn for initial monitoring purpose is also reported. The DOAS system is able to measure ammonia concentrations of 2 ppm with fast response time (4 s). Elsevier Ltd 2014 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/6821/1/A_DOAS_System_For_Monitoring_Of_Ammonia_Emission_In_The_Agricultural_Sector.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/6821/4/A%20DOAS%20System%20for%20Monitoring%20of%20Ammonia%20Emission%20in%20the%20Agricultural%20Sector.pdf Hadi, Manap and M. S., Najib (2014) A DOAS System For Monitoring Of Ammonia Emission In The Agricultural Sector. Sensors and Actuators B: Chemical, 205. pp. 411-415. ISSN 0925-4005 http://dx.doi.org/10.1016/j.snb.2014.08.080 DOI: 10.1016/j.snb.2014.08.080 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English English |
topic |
T Technology (General) |
spellingShingle |
T Technology (General) Hadi, Manap M. S., Najib A DOAS System For Monitoring Of Ammonia Emission In The Agricultural Sector |
description |
Ammonia emission in the atmosphere is a major concern in EU countries. In 2005 it was reported by European Environmental Agency (EEA) that 93% of the EU15 countries come from agricultural sector. This paper reported an open-path differential optical absorption spectroscopy (DOAS) system to monitor ammonia emission in the agricultural sector. In the initial stage, analysis of the absorption lines for ammonia in the ultraviolet region was performed and the optimum wavelength for ammonia measurement was selected at 212 nm. A few tests were conducted to verify the detection system reliability and this DOAS system was able to detect various ammonia concentrations from 0 to 100 ppm. It is also shown that this DOAS system has better response and recovery time than a chemisorption sensor. In this paper, ammonia levels measurement in a cattle barn for initial monitoring purpose is also reported. The DOAS system is able to measure ammonia concentrations of 2 ppm with fast response time (4 s). |
format |
Article |
author |
Hadi, Manap M. S., Najib |
author_facet |
Hadi, Manap M. S., Najib |
author_sort |
Hadi, Manap |
title |
A DOAS System For Monitoring Of Ammonia Emission In The Agricultural Sector |
title_short |
A DOAS System For Monitoring Of Ammonia Emission In The Agricultural Sector |
title_full |
A DOAS System For Monitoring Of Ammonia Emission In The Agricultural Sector |
title_fullStr |
A DOAS System For Monitoring Of Ammonia Emission In The Agricultural Sector |
title_full_unstemmed |
A DOAS System For Monitoring Of Ammonia Emission In The Agricultural Sector |
title_sort |
doas system for monitoring of ammonia emission in the agricultural sector |
publisher |
Elsevier Ltd |
publishDate |
2014 |
url |
http://umpir.ump.edu.my/id/eprint/6821/ http://umpir.ump.edu.my/id/eprint/6821/ http://umpir.ump.edu.my/id/eprint/6821/ http://umpir.ump.edu.my/id/eprint/6821/1/A_DOAS_System_For_Monitoring_Of_Ammonia_Emission_In_The_Agricultural_Sector.pdf http://umpir.ump.edu.my/id/eprint/6821/4/A%20DOAS%20System%20for%20Monitoring%20of%20Ammonia%20Emission%20in%20the%20Agricultural%20Sector.pdf |
first_indexed |
2023-09-18T22:02:56Z |
last_indexed |
2023-09-18T22:02:56Z |
_version_ |
1777414519286398976 |