Utilization of the Acoustic Emission Technology in Bone Tissues

The main subject of this study was to establish a meaningful significance of the acoustic emission technology to be incorporated in the pedicle screw fixation procedure. Its purpose was to find a replacement technique using the acoustic emission technology instead of keep using the conventional way...

Full description

Bibliographic Details
Main Authors: Miminorazeansuhaila, Loman, Che Ku Eddy Nizwan, Che Ku Husin, Mohd Imran, Yusof, Mohd Fadhlan, Yusof
Format: Article
Language:English
Published: Elsevier 2014
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/5340/
http://umpir.ump.edu.my/id/eprint/5340/
http://umpir.ump.edu.my/id/eprint/5340/
http://umpir.ump.edu.my/id/eprint/5340/1/fkm-2014-loman-Utilization%20of%20the%20Acoustic.pdf
id ump-5340
recordtype eprints
spelling ump-53402015-04-27T05:37:58Z http://umpir.ump.edu.my/id/eprint/5340/ Utilization of the Acoustic Emission Technology in Bone Tissues Miminorazeansuhaila, Loman Che Ku Eddy Nizwan, Che Ku Husin Mohd Imran, Yusof Mohd Fadhlan, Yusof TJ Mechanical engineering and machinery The main subject of this study was to establish a meaningful significance of the acoustic emission technology to be incorporated in the pedicle screw fixation procedure. Its purpose was to find a replacement technique using the acoustic emission technology instead of keep using the conventional way which only depends on the surgeons expertise. The experiment of pedicle screw fixation method work was carried out on a goats vertebrae as a lab scale material instead of the human cervical vertebrae. While the experimental work was done, the acoustic emission signatures were then acquired using the Physical Acoustics acoustic emission data acquisition system. Once completed, the acoustic emission signatures were then analysed using Matlab software together with the AEWin software package. From the results obtained, the numbers of data counts are generally bigger for the pedicle screw fixation procedure at early stage of bone penetration compared to the latter. It is significant to the different structure of bones as hard bone technically takes more time to be penetrated compared to the soft ones. This technique undoubtedly has high potential to be studied further so that it can be commercialized into the medical field. Elsevier 2014 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/5340/1/fkm-2014-loman-Utilization%20of%20the%20Acoustic.pdf Miminorazeansuhaila, Loman and Che Ku Eddy Nizwan, Che Ku Husin and Mohd Imran, Yusof and Mohd Fadhlan, Yusof (2014) Utilization of the Acoustic Emission Technology in Bone Tissues. Applied Mechanics and Materials, 471. pp. 218-222. ISSN 1662-7482 http://www.scientific.net/AMM.471.218 DOI :10.4028/www.scientific.net/AMM.471.218
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Miminorazeansuhaila, Loman
Che Ku Eddy Nizwan, Che Ku Husin
Mohd Imran, Yusof
Mohd Fadhlan, Yusof
Utilization of the Acoustic Emission Technology in Bone Tissues
description The main subject of this study was to establish a meaningful significance of the acoustic emission technology to be incorporated in the pedicle screw fixation procedure. Its purpose was to find a replacement technique using the acoustic emission technology instead of keep using the conventional way which only depends on the surgeons expertise. The experiment of pedicle screw fixation method work was carried out on a goats vertebrae as a lab scale material instead of the human cervical vertebrae. While the experimental work was done, the acoustic emission signatures were then acquired using the Physical Acoustics acoustic emission data acquisition system. Once completed, the acoustic emission signatures were then analysed using Matlab software together with the AEWin software package. From the results obtained, the numbers of data counts are generally bigger for the pedicle screw fixation procedure at early stage of bone penetration compared to the latter. It is significant to the different structure of bones as hard bone technically takes more time to be penetrated compared to the soft ones. This technique undoubtedly has high potential to be studied further so that it can be commercialized into the medical field.
format Article
author Miminorazeansuhaila, Loman
Che Ku Eddy Nizwan, Che Ku Husin
Mohd Imran, Yusof
Mohd Fadhlan, Yusof
author_facet Miminorazeansuhaila, Loman
Che Ku Eddy Nizwan, Che Ku Husin
Mohd Imran, Yusof
Mohd Fadhlan, Yusof
author_sort Miminorazeansuhaila, Loman
title Utilization of the Acoustic Emission Technology in Bone Tissues
title_short Utilization of the Acoustic Emission Technology in Bone Tissues
title_full Utilization of the Acoustic Emission Technology in Bone Tissues
title_fullStr Utilization of the Acoustic Emission Technology in Bone Tissues
title_full_unstemmed Utilization of the Acoustic Emission Technology in Bone Tissues
title_sort utilization of the acoustic emission technology in bone tissues
publisher Elsevier
publishDate 2014
url http://umpir.ump.edu.my/id/eprint/5340/
http://umpir.ump.edu.my/id/eprint/5340/
http://umpir.ump.edu.my/id/eprint/5340/
http://umpir.ump.edu.my/id/eprint/5340/1/fkm-2014-loman-Utilization%20of%20the%20Acoustic.pdf
first_indexed 2023-09-18T22:00:38Z
last_indexed 2023-09-18T22:00:38Z
_version_ 1777414374957252608