A comparative study on anaerobic treatment between ponding system and digester tank system for palm oil mill effluent (POME) treatment

Palm oil is one of the important industrial sectors in Malaysia.Every year,the production of palm oil increased rapidly.As the production of palm oil increased, more palm oil mill effluent(POME)is generated annually.The total annual quantity of wastewater generated is estimated to be 1.8×106m3.This...

Full description

Bibliographic Details
Main Author: Intan Safinaz, Ismail
Format: Undergraduates Project Papers
Language:English
Published: 2010
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/5140/
http://umpir.ump.edu.my/id/eprint/5140/
http://umpir.ump.edu.my/id/eprint/5140/1/CD5148.pdf
id ump-5140
recordtype eprints
spelling ump-51402015-03-03T09:23:19Z http://umpir.ump.edu.my/id/eprint/5140/ A comparative study on anaerobic treatment between ponding system and digester tank system for palm oil mill effluent (POME) treatment Intan Safinaz, Ismail TD Environmental technology. Sanitary engineering Palm oil is one of the important industrial sectors in Malaysia.Every year,the production of palm oil increased rapidly.As the production of palm oil increased, more palm oil mill effluent(POME)is generated annually.The total annual quantity of wastewater generated is estimated to be 1.8×106m3.This situation contributed to more study on the technology of treatment of the POME.Raw POME comprises of water-soluble components of the palm fruits as well as some suspended materials like palm fibre and oil and it cannot be discharged into the watercourse directly.The effluent must be treated to acceptable quality before it can be discharged.Comparison on conventional system and alternative system for anaerobic treatment between ponding system and digestion tank treatment system was used for treatment POME. The resources of this data are taken from the selected Palm oil Mill Plantations.The main parameters for POME are BOD, COD, Suspended Solid,and Oil & Grease.The reduction of main parameters for Ponding System and Digester Tank System was determine which is BOD, 96.88% and 98.06%,COD,90.60% and 92.70%,SS,94.03% and 96.83% and O&G,97.21% and 81.33%. Meanwhile,the quality,effectiveness and the advantages and disadvantages for both systems also were determined.The findings show that alternative treatment system which is Digester Tank System having efficiency, effective and ability to treat POME better than conventional treatment system. 2010-11 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/5140/1/CD5148.pdf Intan Safinaz, Ismail (2010) A comparative study on anaerobic treatment between ponding system and digester tank system for palm oil mill effluent (POME) treatment. Faculty of Civil Engineering & Earth Resources, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:52189&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TD Environmental technology. Sanitary engineering
spellingShingle TD Environmental technology. Sanitary engineering
Intan Safinaz, Ismail
A comparative study on anaerobic treatment between ponding system and digester tank system for palm oil mill effluent (POME) treatment
description Palm oil is one of the important industrial sectors in Malaysia.Every year,the production of palm oil increased rapidly.As the production of palm oil increased, more palm oil mill effluent(POME)is generated annually.The total annual quantity of wastewater generated is estimated to be 1.8×106m3.This situation contributed to more study on the technology of treatment of the POME.Raw POME comprises of water-soluble components of the palm fruits as well as some suspended materials like palm fibre and oil and it cannot be discharged into the watercourse directly.The effluent must be treated to acceptable quality before it can be discharged.Comparison on conventional system and alternative system for anaerobic treatment between ponding system and digestion tank treatment system was used for treatment POME. The resources of this data are taken from the selected Palm oil Mill Plantations.The main parameters for POME are BOD, COD, Suspended Solid,and Oil & Grease.The reduction of main parameters for Ponding System and Digester Tank System was determine which is BOD, 96.88% and 98.06%,COD,90.60% and 92.70%,SS,94.03% and 96.83% and O&G,97.21% and 81.33%. Meanwhile,the quality,effectiveness and the advantages and disadvantages for both systems also were determined.The findings show that alternative treatment system which is Digester Tank System having efficiency, effective and ability to treat POME better than conventional treatment system.
format Undergraduates Project Papers
author Intan Safinaz, Ismail
author_facet Intan Safinaz, Ismail
author_sort Intan Safinaz, Ismail
title A comparative study on anaerobic treatment between ponding system and digester tank system for palm oil mill effluent (POME) treatment
title_short A comparative study on anaerobic treatment between ponding system and digester tank system for palm oil mill effluent (POME) treatment
title_full A comparative study on anaerobic treatment between ponding system and digester tank system for palm oil mill effluent (POME) treatment
title_fullStr A comparative study on anaerobic treatment between ponding system and digester tank system for palm oil mill effluent (POME) treatment
title_full_unstemmed A comparative study on anaerobic treatment between ponding system and digester tank system for palm oil mill effluent (POME) treatment
title_sort comparative study on anaerobic treatment between ponding system and digester tank system for palm oil mill effluent (pome) treatment
publishDate 2010
url http://umpir.ump.edu.my/id/eprint/5140/
http://umpir.ump.edu.my/id/eprint/5140/
http://umpir.ump.edu.my/id/eprint/5140/1/CD5148.pdf
first_indexed 2023-09-18T22:00:20Z
last_indexed 2023-09-18T22:00:20Z
_version_ 1777414355922452480