Computer-based instrumentation for pressure instrument using visual basic application

Generally, the project is about the implementation Graphical User Interface (GUI) of Visual Basic on pressure measurement. The focus on my project is to develop an interface of instrumentation systems for pressure measurement and to integrate the pressure transmitter to software system. This project...

Full description

Bibliographic Details
Main Author: Mohd Aizat Faiz, Mohd Yazid
Format: Undergraduates Project Papers
Language:English
Published: 2008
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/502/
http://umpir.ump.edu.my/id/eprint/502/
http://umpir.ump.edu.my/id/eprint/502/1/MOHD_AIZAT_FAIZ_BIN_MOHD_YAZID.pdf
id ump-502
recordtype eprints
spelling ump-5022015-03-03T06:03:49Z http://umpir.ump.edu.my/id/eprint/502/ Computer-based instrumentation for pressure instrument using visual basic application Mohd Aizat Faiz, Mohd Yazid QC Physics Generally, the project is about the implementation Graphical User Interface (GUI) of Visual Basic on pressure measurement. The focus on my project is to develop an interface of instrumentation systems for pressure measurement and to integrate the pressure transmitter to software system. This project can be separated into 2 parts which are software and hardware. Using Visual Basic 2008 as software, I develop the GUI so that it can be used for academic purpose especially in laboratory for BEE 4632 Industrial instrumentation subject. This software can be integrated with pressure transmitter using DAQ Board. In my case, I used Advantech USB-47I6 DAQ Boards because it used USB port as connector from instrument to computer. This DAQ Board is easy to use because it comes with installation for plug and play function, English version manual and Device Manager. For instrument, I used Differential Pressure Transmitter. User needs to key in minimum and maximum MSU applied and minimum and maximum Desired UUT in Data Page tab before further to get the actual UUT. After run 3 times of experiment and completing the table, user can calculate the average and output error. Then they can continue to get an average and output error percentage curve in Graph Page tab. Implementation of GUI to this instrumentation system can help to increase the efficiency in calculating the output data. 2008-11 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/502/1/MOHD_AIZAT_FAIZ_BIN_MOHD_YAZID.pdf Mohd Aizat Faiz, Mohd Yazid (2008) Computer-based instrumentation for pressure instrument using visual basic application. Fakulti Kejuruteraan Elektrik & Elektronik, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:38441&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic QC Physics
spellingShingle QC Physics
Mohd Aizat Faiz, Mohd Yazid
Computer-based instrumentation for pressure instrument using visual basic application
description Generally, the project is about the implementation Graphical User Interface (GUI) of Visual Basic on pressure measurement. The focus on my project is to develop an interface of instrumentation systems for pressure measurement and to integrate the pressure transmitter to software system. This project can be separated into 2 parts which are software and hardware. Using Visual Basic 2008 as software, I develop the GUI so that it can be used for academic purpose especially in laboratory for BEE 4632 Industrial instrumentation subject. This software can be integrated with pressure transmitter using DAQ Board. In my case, I used Advantech USB-47I6 DAQ Boards because it used USB port as connector from instrument to computer. This DAQ Board is easy to use because it comes with installation for plug and play function, English version manual and Device Manager. For instrument, I used Differential Pressure Transmitter. User needs to key in minimum and maximum MSU applied and minimum and maximum Desired UUT in Data Page tab before further to get the actual UUT. After run 3 times of experiment and completing the table, user can calculate the average and output error. Then they can continue to get an average and output error percentage curve in Graph Page tab. Implementation of GUI to this instrumentation system can help to increase the efficiency in calculating the output data.
format Undergraduates Project Papers
author Mohd Aizat Faiz, Mohd Yazid
author_facet Mohd Aizat Faiz, Mohd Yazid
author_sort Mohd Aizat Faiz, Mohd Yazid
title Computer-based instrumentation for pressure instrument using visual basic application
title_short Computer-based instrumentation for pressure instrument using visual basic application
title_full Computer-based instrumentation for pressure instrument using visual basic application
title_fullStr Computer-based instrumentation for pressure instrument using visual basic application
title_full_unstemmed Computer-based instrumentation for pressure instrument using visual basic application
title_sort computer-based instrumentation for pressure instrument using visual basic application
publishDate 2008
url http://umpir.ump.edu.my/id/eprint/502/
http://umpir.ump.edu.my/id/eprint/502/
http://umpir.ump.edu.my/id/eprint/502/1/MOHD_AIZAT_FAIZ_BIN_MOHD_YAZID.pdf
first_indexed 2023-09-18T21:52:47Z
last_indexed 2023-09-18T21:52:47Z
_version_ 1777413880545280000