Development of earth leakage circuit breaker with an auto re-closer unit

Power system protection is the most important requirement before the power system is put into operation. Electrical energy has caused dangers both to the human and the machines. Protection system is mostly controlled by the Earth Leakage Circuit Breaker (ELCB). This device is the brain of the protec...

Full description

Bibliographic Details
Main Author: Mohd Tarmizi, Rahim
Format: Undergraduates Project Papers
Language:English
Published: 2009
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/377/
http://umpir.ump.edu.my/id/eprint/377/
http://umpir.ump.edu.my/id/eprint/377/1/tarmizi.pdf
id ump-377
recordtype eprints
spelling ump-3772015-03-03T06:16:51Z http://umpir.ump.edu.my/id/eprint/377/ Development of earth leakage circuit breaker with an auto re-closer unit Mohd Tarmizi, Rahim TK Electrical engineering. Electronics Nuclear engineering Power system protection is the most important requirement before the power system is put into operation. Electrical energy has caused dangers both to the human and the machines. Protection system is mostly controlled by the Earth Leakage Circuit Breaker (ELCB). This device is the brain of the protection system that monitors input current from power line by it sensor Zero phase Current Transformer (ZCT), then sending the signals to the mechanical switch to tripped the circuit breaker. ELCB is widely applied by consumer weather it is for resident, factory, laboratory and also power distribution. Power system protection can be implemented at various stages and various types of protection devices. Because industrial operation requires protection of their Equipment from the lightning, short-circuit and also over-current, so the ELCB will serve the purpose as the protection of their system. This project will attempt to improve and design the currently ELCB by using PIC microcontroller so that it have the ability to identify the fault, act accordingly, display the fault and also to re-close it back to normal. The PIC micro controller will cause the ELCB to trip when there is unbalance current from power line flow through life line and neutral line is ≥100mA. In order to design it, first thing of the current from the power line need to be measure in order to monitor it using ZCT including testing the fault (over current, lightning and short circuit) and when such condition arise, it will isolate the load from power line in the shortest time possible without harming the any other electrical devices. In this project PIC microcontroller will be used to control and operate the SSR, thus replacing the current mechanical switch. 2009-05 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/377/1/tarmizi.pdf Mohd Tarmizi, Rahim (2009) Development of earth leakage circuit breaker with an auto re-closer unit. Faculty of Electrical & Electronic Engineering, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:40392&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Mohd Tarmizi, Rahim
Development of earth leakage circuit breaker with an auto re-closer unit
description Power system protection is the most important requirement before the power system is put into operation. Electrical energy has caused dangers both to the human and the machines. Protection system is mostly controlled by the Earth Leakage Circuit Breaker (ELCB). This device is the brain of the protection system that monitors input current from power line by it sensor Zero phase Current Transformer (ZCT), then sending the signals to the mechanical switch to tripped the circuit breaker. ELCB is widely applied by consumer weather it is for resident, factory, laboratory and also power distribution. Power system protection can be implemented at various stages and various types of protection devices. Because industrial operation requires protection of their Equipment from the lightning, short-circuit and also over-current, so the ELCB will serve the purpose as the protection of their system. This project will attempt to improve and design the currently ELCB by using PIC microcontroller so that it have the ability to identify the fault, act accordingly, display the fault and also to re-close it back to normal. The PIC micro controller will cause the ELCB to trip when there is unbalance current from power line flow through life line and neutral line is ≥100mA. In order to design it, first thing of the current from the power line need to be measure in order to monitor it using ZCT including testing the fault (over current, lightning and short circuit) and when such condition arise, it will isolate the load from power line in the shortest time possible without harming the any other electrical devices. In this project PIC microcontroller will be used to control and operate the SSR, thus replacing the current mechanical switch.
format Undergraduates Project Papers
author Mohd Tarmizi, Rahim
author_facet Mohd Tarmizi, Rahim
author_sort Mohd Tarmizi, Rahim
title Development of earth leakage circuit breaker with an auto re-closer unit
title_short Development of earth leakage circuit breaker with an auto re-closer unit
title_full Development of earth leakage circuit breaker with an auto re-closer unit
title_fullStr Development of earth leakage circuit breaker with an auto re-closer unit
title_full_unstemmed Development of earth leakage circuit breaker with an auto re-closer unit
title_sort development of earth leakage circuit breaker with an auto re-closer unit
publishDate 2009
url http://umpir.ump.edu.my/id/eprint/377/
http://umpir.ump.edu.my/id/eprint/377/
http://umpir.ump.edu.my/id/eprint/377/1/tarmizi.pdf
first_indexed 2023-09-18T21:52:31Z
last_indexed 2023-09-18T21:52:31Z
_version_ 1777413863367507968