Determination of correlation between backflow volume and mitral valve leaflet young modulus from two dimensional echocardiogram images
Mitral valve prolapse without proper monitoring might lead to a severe mitral valve failure which eventually leads to a sudden death. Additional information on the mitral valve leaflet condition against the backflow volume would be an added advantage to the medical practitioner for their decision on...
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
AIP Publishing
2012
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/26919/ http://umpir.ump.edu.my/id/eprint/26919/ http://umpir.ump.edu.my/id/eprint/26919/1/Determination%20of%20correlation%20between%20backflow%20volume%20and%20mitral.pdf |
id |
ump-26919 |
---|---|
recordtype |
eprints |
spelling |
ump-269192020-03-18T03:21:35Z http://umpir.ump.edu.my/id/eprint/26919/ Determination of correlation between backflow volume and mitral valve leaflet young modulus from two dimensional echocardiogram images P. Jonga, Rudiyanto Kahar, Osman Mohd Azrul Hisham, Mohd Adib TJ Mechanical engineering and machinery Mitral valve prolapse without proper monitoring might lead to a severe mitral valve failure which eventually leads to a sudden death. Additional information on the mitral valve leaflet condition against the backflow volume would be an added advantage to the medical practitioner for their decision on the patients' treatment. A study on two dimensional echocardiography images has been conducted and the correlations between the backflow volume of the mitral regurgitation and mitral valve leaflet Young modulus have been obtained. Echocardiogram images were analyzed on the aspect of backflow volume percentage and mitral valve leaflet dimensions on different rates of backflow volume. Young modulus values for the mitral valve leaflet were obtained by using the principle of elastic deflection and deformation on the mitral valve leaflet. The results show that the backflow volume increased with the decrease of the mitral valve leaflet Young modulus which also indicate the condition of the mitral valve leaflet approaching failure at high backflow volumes. Mitral valve leaflet Young modulus values obtained in this study agreed with the healthy mitral valve leaflet Young modulus from the literature. This is an initial overview of the trend on the prediction of the behaviour between the fluid and the structure of the blood and the mitral valve which is extendable to a larger system of prediction on the mitral valve leaflet condition based on the available echocardiogram images. AIP Publishing 2012 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/26919/1/Determination%20of%20correlation%20between%20backflow%20volume%20and%20mitral.pdf P. Jonga, Rudiyanto and Kahar, Osman and Mohd Azrul Hisham, Mohd Adib (2012) Determination of correlation between backflow volume and mitral valve leaflet young modulus from two dimensional echocardiogram images. In: AIP Conference Proceedings: The 4th International Meeting Of Advances In Thermofluids (IMAT 2011), 3-4 October 2011 , Melaka. pp. 604-611., 1440. ISSN 0094-243X https://doi.org/10.1063/1.4704269 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery P. Jonga, Rudiyanto Kahar, Osman Mohd Azrul Hisham, Mohd Adib Determination of correlation between backflow volume and mitral valve leaflet young modulus from two dimensional echocardiogram images |
description |
Mitral valve prolapse without proper monitoring might lead to a severe mitral valve failure which eventually leads to a sudden death. Additional information on the mitral valve leaflet condition against the backflow volume would be an added advantage to the medical practitioner for their decision on the patients' treatment. A study on two dimensional echocardiography images has been conducted and the correlations between the backflow volume of the mitral regurgitation and mitral valve leaflet Young modulus have been obtained. Echocardiogram images were analyzed on the aspect of backflow volume percentage and mitral valve leaflet dimensions on different rates of backflow volume. Young modulus values for the mitral valve leaflet were obtained by using the principle of elastic deflection and deformation on the mitral valve leaflet. The results show that the backflow volume increased with the decrease of the mitral valve leaflet Young modulus which also indicate the condition of the mitral valve leaflet approaching failure at high backflow volumes. Mitral valve leaflet Young modulus values obtained in this study agreed with the healthy mitral valve leaflet Young modulus from the literature. This is an initial overview of the trend on the prediction of the behaviour between the fluid and the structure of the blood and the mitral valve which is extendable to a larger system of prediction on the mitral valve leaflet condition based on the available echocardiogram images. |
format |
Conference or Workshop Item |
author |
P. Jonga, Rudiyanto Kahar, Osman Mohd Azrul Hisham, Mohd Adib |
author_facet |
P. Jonga, Rudiyanto Kahar, Osman Mohd Azrul Hisham, Mohd Adib |
author_sort |
P. Jonga, Rudiyanto |
title |
Determination of correlation between backflow volume and mitral valve leaflet young modulus from two dimensional echocardiogram images |
title_short |
Determination of correlation between backflow volume and mitral valve leaflet young modulus from two dimensional echocardiogram images |
title_full |
Determination of correlation between backflow volume and mitral valve leaflet young modulus from two dimensional echocardiogram images |
title_fullStr |
Determination of correlation between backflow volume and mitral valve leaflet young modulus from two dimensional echocardiogram images |
title_full_unstemmed |
Determination of correlation between backflow volume and mitral valve leaflet young modulus from two dimensional echocardiogram images |
title_sort |
determination of correlation between backflow volume and mitral valve leaflet young modulus from two dimensional echocardiogram images |
publisher |
AIP Publishing |
publishDate |
2012 |
url |
http://umpir.ump.edu.my/id/eprint/26919/ http://umpir.ump.edu.my/id/eprint/26919/ http://umpir.ump.edu.my/id/eprint/26919/1/Determination%20of%20correlation%20between%20backflow%20volume%20and%20mitral.pdf |
first_indexed |
2023-09-18T22:42:12Z |
last_indexed |
2023-09-18T22:42:12Z |
_version_ |
1777416990102650880 |