Fluctuation of salivary α-amylase affected by the time change of injection

In previous study, we have proposed a pain evaluation test by measuring a stress factor which is fluctuation of salivary α-amylase (sAA) on mice. During the experiment, mice were injected on the same period of time by different diameter size of needles which have the same degree of bevel and length....

Full description

Bibliographic Details
Main Authors: Mohd, Yusri, Tsuchiya, Kazuyoshi, Kajiwarad, Kagemasa, Kimura, Minoru
Format: Conference or Workshop Item
Language:English
Published: IEEE 2012
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/26888/
http://umpir.ump.edu.my/id/eprint/26888/
http://umpir.ump.edu.my/id/eprint/26888/1/Fluctuation%20of%20salivary%20%CE%B1-amylase%20affected%20by%20the%20time%20change%20of%20injection.pdf
id ump-26888
recordtype eprints
spelling ump-268882020-03-19T07:26:18Z http://umpir.ump.edu.my/id/eprint/26888/ Fluctuation of salivary α-amylase affected by the time change of injection Mohd, Yusri Tsuchiya, Kazuyoshi Kajiwarad, Kagemasa Kimura, Minoru TJ Mechanical engineering and machinery In previous study, we have proposed a pain evaluation test by measuring a stress factor which is fluctuation of salivary α-amylase (sAA) on mice. During the experiment, mice were injected on the same period of time by different diameter size of needles which have the same degree of bevel and length. For injection groups, the mice were injected for 3 seconds with depth of 3mm in vertical direction on femoral region of mice. Next, Mann Whitney-U tests were adopted and the measurement from injection groups and control group were compared. According to the result, the marginal outer diameter of the needle within painless region were confirmed at 95 μm ≤ X (outer diameter) <; 100 μm. In this study, mice were injected on the different period of time by the same type of needle, 95 μm of outer diameter, which was confirmed as the marginal outer diameter of the needle within painless region. Then, whole saliva will be collected and measured by absorptiometry method before the fluctuations of sAA were observed. IEEE 2012 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/26888/1/Fluctuation%20of%20salivary%20%CE%B1-amylase%20affected%20by%20the%20time%20change%20of%20injection.pdf Mohd, Yusri and Tsuchiya, Kazuyoshi and Kajiwarad, Kagemasa and Kimura, Minoru (2012) Fluctuation of salivary α-amylase affected by the time change of injection. In: IEEE International Symposium on Micro-NanoMechatronics and Human Science (MHS) 2012, 4-7 Novemver 2012 , Nagoya, Japan. pp. 24-28.. ISBN 978-1-4673-4813-3 https://doi.org/10.1109/MHS.2012.6492394
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Mohd, Yusri
Tsuchiya, Kazuyoshi
Kajiwarad, Kagemasa
Kimura, Minoru
Fluctuation of salivary α-amylase affected by the time change of injection
description In previous study, we have proposed a pain evaluation test by measuring a stress factor which is fluctuation of salivary α-amylase (sAA) on mice. During the experiment, mice were injected on the same period of time by different diameter size of needles which have the same degree of bevel and length. For injection groups, the mice were injected for 3 seconds with depth of 3mm in vertical direction on femoral region of mice. Next, Mann Whitney-U tests were adopted and the measurement from injection groups and control group were compared. According to the result, the marginal outer diameter of the needle within painless region were confirmed at 95 μm ≤ X (outer diameter) <; 100 μm. In this study, mice were injected on the different period of time by the same type of needle, 95 μm of outer diameter, which was confirmed as the marginal outer diameter of the needle within painless region. Then, whole saliva will be collected and measured by absorptiometry method before the fluctuations of sAA were observed.
format Conference or Workshop Item
author Mohd, Yusri
Tsuchiya, Kazuyoshi
Kajiwarad, Kagemasa
Kimura, Minoru
author_facet Mohd, Yusri
Tsuchiya, Kazuyoshi
Kajiwarad, Kagemasa
Kimura, Minoru
author_sort Mohd, Yusri
title Fluctuation of salivary α-amylase affected by the time change of injection
title_short Fluctuation of salivary α-amylase affected by the time change of injection
title_full Fluctuation of salivary α-amylase affected by the time change of injection
title_fullStr Fluctuation of salivary α-amylase affected by the time change of injection
title_full_unstemmed Fluctuation of salivary α-amylase affected by the time change of injection
title_sort fluctuation of salivary α-amylase affected by the time change of injection
publisher IEEE
publishDate 2012
url http://umpir.ump.edu.my/id/eprint/26888/
http://umpir.ump.edu.my/id/eprint/26888/
http://umpir.ump.edu.my/id/eprint/26888/1/Fluctuation%20of%20salivary%20%CE%B1-amylase%20affected%20by%20the%20time%20change%20of%20injection.pdf
first_indexed 2023-09-18T22:42:09Z
last_indexed 2023-09-18T22:42:09Z
_version_ 1777416986225016832