Fluctuation of salivary α-amylase affected by the time change of injection
In previous study, we have proposed a pain evaluation test by measuring a stress factor which is fluctuation of salivary α-amylase (sAA) on mice. During the experiment, mice were injected on the same period of time by different diameter size of needles which have the same degree of bevel and length....
Main Authors: | , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IEEE
2012
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/26888/ http://umpir.ump.edu.my/id/eprint/26888/ http://umpir.ump.edu.my/id/eprint/26888/1/Fluctuation%20of%20salivary%20%CE%B1-amylase%20affected%20by%20the%20time%20change%20of%20injection.pdf |
id |
ump-26888 |
---|---|
recordtype |
eprints |
spelling |
ump-268882020-03-19T07:26:18Z http://umpir.ump.edu.my/id/eprint/26888/ Fluctuation of salivary α-amylase affected by the time change of injection Mohd, Yusri Tsuchiya, Kazuyoshi Kajiwarad, Kagemasa Kimura, Minoru TJ Mechanical engineering and machinery In previous study, we have proposed a pain evaluation test by measuring a stress factor which is fluctuation of salivary α-amylase (sAA) on mice. During the experiment, mice were injected on the same period of time by different diameter size of needles which have the same degree of bevel and length. For injection groups, the mice were injected for 3 seconds with depth of 3mm in vertical direction on femoral region of mice. Next, Mann Whitney-U tests were adopted and the measurement from injection groups and control group were compared. According to the result, the marginal outer diameter of the needle within painless region were confirmed at 95 μm ≤ X (outer diameter) <; 100 μm. In this study, mice were injected on the different period of time by the same type of needle, 95 μm of outer diameter, which was confirmed as the marginal outer diameter of the needle within painless region. Then, whole saliva will be collected and measured by absorptiometry method before the fluctuations of sAA were observed. IEEE 2012 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/26888/1/Fluctuation%20of%20salivary%20%CE%B1-amylase%20affected%20by%20the%20time%20change%20of%20injection.pdf Mohd, Yusri and Tsuchiya, Kazuyoshi and Kajiwarad, Kagemasa and Kimura, Minoru (2012) Fluctuation of salivary α-amylase affected by the time change of injection. In: IEEE International Symposium on Micro-NanoMechatronics and Human Science (MHS) 2012, 4-7 Novemver 2012 , Nagoya, Japan. pp. 24-28.. ISBN 978-1-4673-4813-3 https://doi.org/10.1109/MHS.2012.6492394 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Mohd, Yusri Tsuchiya, Kazuyoshi Kajiwarad, Kagemasa Kimura, Minoru Fluctuation of salivary α-amylase affected by the time change of injection |
description |
In previous study, we have proposed a pain evaluation test by measuring a stress factor which is fluctuation of salivary α-amylase (sAA) on mice. During the experiment, mice were injected on the same period of time by different diameter size of needles which have the same degree of bevel and length. For injection groups, the mice were injected for 3 seconds with depth of 3mm in vertical direction on femoral region of mice. Next, Mann Whitney-U tests were adopted and the measurement from injection groups and control group were compared. According to the result, the marginal outer diameter of the needle within painless region were confirmed at 95 μm ≤ X (outer diameter) <; 100 μm. In this study, mice were injected on the different period of time by the same type of needle, 95 μm of outer diameter, which was confirmed as the marginal outer diameter of the needle within painless region. Then, whole saliva will be collected and measured by absorptiometry method before the fluctuations of sAA were observed. |
format |
Conference or Workshop Item |
author |
Mohd, Yusri Tsuchiya, Kazuyoshi Kajiwarad, Kagemasa Kimura, Minoru |
author_facet |
Mohd, Yusri Tsuchiya, Kazuyoshi Kajiwarad, Kagemasa Kimura, Minoru |
author_sort |
Mohd, Yusri |
title |
Fluctuation of salivary α-amylase affected by the time change of injection |
title_short |
Fluctuation of salivary α-amylase affected by the time change of injection |
title_full |
Fluctuation of salivary α-amylase affected by the time change of injection |
title_fullStr |
Fluctuation of salivary α-amylase affected by the time change of injection |
title_full_unstemmed |
Fluctuation of salivary α-amylase affected by the time change of injection |
title_sort |
fluctuation of salivary α-amylase affected by the time change of injection |
publisher |
IEEE |
publishDate |
2012 |
url |
http://umpir.ump.edu.my/id/eprint/26888/ http://umpir.ump.edu.my/id/eprint/26888/ http://umpir.ump.edu.my/id/eprint/26888/1/Fluctuation%20of%20salivary%20%CE%B1-amylase%20affected%20by%20the%20time%20change%20of%20injection.pdf |
first_indexed |
2023-09-18T22:42:09Z |
last_indexed |
2023-09-18T22:42:09Z |
_version_ |
1777416986225016832 |