Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates

Separation of oxygen and nitrogen gas was studied by using tubular carbon membranes (TCMs) prepared from polymeric precursors. A coating procedure called dip-coating technique was employed to fabricate the TCMs using P84 copolyimide (PI) and nanocrystalline cellulose (NCC) as the main precursor and...

Full description

Bibliographic Details
Main Authors: Norazlianie, Sazali, W. N. W., Salleh, A. F., Ismail, Murakamid, Hideyuki, Iwamotoe, Yuji
Format: Article
Language:English
Published: Taylor & Francis 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/26236/
http://umpir.ump.edu.my/id/eprint/26236/
http://umpir.ump.edu.my/id/eprint/26236/
http://umpir.ump.edu.my/id/eprint/26236/1/Oxygen%20separation%20through%20p84%20copolyimide1.pdf
id ump-26236
recordtype eprints
spelling ump-262362019-10-30T01:51:18Z http://umpir.ump.edu.my/id/eprint/26236/ Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates Norazlianie, Sazali W. N. W., Salleh A. F., Ismail Murakamid, Hideyuki Iwamotoe, Yuji QD Chemistry Separation of oxygen and nitrogen gas was studied by using tubular carbon membranes (TCMs) prepared from polymeric precursors. A coating procedure called dip-coating technique was employed to fabricate the TCMs using P84 copolyimide (PI) and nanocrystalline cellulose (NCC) as the main precursor and additive, respectively. Previous study has proved that properties of PI/NCC can be altered by changing the carbonization parameter, i.e. time, temperature, and environment. PI/NCC deposition on the ceramic tubular support was employed to produce diverse TCMs for gas separation via simple carbonization process. In this study, manipulation of heating rate was done to observe the effect of TCMs on gas permeation by setting the heating rate at 1, 3, 5, and 7C min–1. It was proved that heating rate during PI/NCC-based carbon membrane fabrication played a significant role in gas ideal selectivity test. In addition, heating rate at (3C min–1) showed an improvement in the membrane ideal selectivity but a reduction in the permeability. Taylor & Francis 2019 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/26236/1/Oxygen%20separation%20through%20p84%20copolyimide1.pdf Norazlianie, Sazali and W. N. W., Salleh and A. F., Ismail and Murakamid, Hideyuki and Iwamotoe, Yuji (2019) Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates. Chemical Engineering Communications. pp. 1-11. ISSN 1563-5201 https://doi.org/10.1080/00986445.2019.1631163 https://doi.org/10.1080/00986445.2019.1631163
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic QD Chemistry
spellingShingle QD Chemistry
Norazlianie, Sazali
W. N. W., Salleh
A. F., Ismail
Murakamid, Hideyuki
Iwamotoe, Yuji
Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates
description Separation of oxygen and nitrogen gas was studied by using tubular carbon membranes (TCMs) prepared from polymeric precursors. A coating procedure called dip-coating technique was employed to fabricate the TCMs using P84 copolyimide (PI) and nanocrystalline cellulose (NCC) as the main precursor and additive, respectively. Previous study has proved that properties of PI/NCC can be altered by changing the carbonization parameter, i.e. time, temperature, and environment. PI/NCC deposition on the ceramic tubular support was employed to produce diverse TCMs for gas separation via simple carbonization process. In this study, manipulation of heating rate was done to observe the effect of TCMs on gas permeation by setting the heating rate at 1, 3, 5, and 7C min–1. It was proved that heating rate during PI/NCC-based carbon membrane fabrication played a significant role in gas ideal selectivity test. In addition, heating rate at (3C min–1) showed an improvement in the membrane ideal selectivity but a reduction in the permeability.
format Article
author Norazlianie, Sazali
W. N. W., Salleh
A. F., Ismail
Murakamid, Hideyuki
Iwamotoe, Yuji
author_facet Norazlianie, Sazali
W. N. W., Salleh
A. F., Ismail
Murakamid, Hideyuki
Iwamotoe, Yuji
author_sort Norazlianie, Sazali
title Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates
title_short Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates
title_full Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates
title_fullStr Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates
title_full_unstemmed Oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: Impact of heating rates
title_sort oxygen separation through p84 copolyimide/nanocrystalline cellulose carbon membrane: impact of heating rates
publisher Taylor & Francis
publishDate 2019
url http://umpir.ump.edu.my/id/eprint/26236/
http://umpir.ump.edu.my/id/eprint/26236/
http://umpir.ump.edu.my/id/eprint/26236/
http://umpir.ump.edu.my/id/eprint/26236/1/Oxygen%20separation%20through%20p84%20copolyimide1.pdf
first_indexed 2023-09-18T22:40:44Z
last_indexed 2023-09-18T22:40:44Z
_version_ 1777416897359249408