Determination of direction factor, Md for MS1553:2002 wind loading for building structure

Current records from the Malaysia natural disaster studies show that windstorm -causes damages to building. Even though Malaysia has developed 'own code of -practice on wind loading for building structure to support MalaysianStandard -in 2002, ongoing research is still being carried out to up...

Full description

Bibliographic Details
Main Author: Hamizah, Jasmi
Format: Undergraduates Project Papers
Language:English
Published: 2010
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/2566/
http://umpir.ump.edu.my/id/eprint/2566/1/HAMIZAH_BT_JASMI.PDF
id ump-2566
recordtype eprints
spelling ump-25662015-03-03T07:57:17Z http://umpir.ump.edu.my/id/eprint/2566/ Determination of direction factor, Md for MS1553:2002 wind loading for building structure Hamizah, Jasmi TH Building construction Current records from the Malaysia natural disaster studies show that windstorm -causes damages to building. Even though Malaysia has developed 'own code of -practice on wind loading for building structure to support MalaysianStandard -in 2002, ongoing research is still being carried out to update the data in the codes Currently, in Malaysia is refer to Malaysian Standard, MS 15532002 that do not have -the value -of-direction factor, 'Ma. Most -of'design methods in Malaysia are not considering-the effect of wind direction.. .Significantly; .buil'ding orientation on design stage can reduce the wind load impact. Wind speeds data from eights Meteorological Station over the peninsular Malaysia are used in this study. 'Extreme wind speed are -examined by -statistical 'technique -namely -Gumbel method. The 'extreme wind 'speed -data are considered into Iwo conditions, i) Non-Direction Method,(ii) Directional' Method. By using this method extreme wind can be determined at 8 stations in Peninsular 'Malaysia Which are Kuantan, KuaiaTerengganu, 'Mersing, Senal, Subang, -Bayan -Lepas, 'chuping, and Melaka. -From -the 'result, -the 'direction -factor, NTd station was found and the values are recommending in MS 1553:2002. The results also have shown that, at some direction of extreme wind predicted stronger than non direction method. Furthermore 'these values can give guideline 'to The designer to 'orientate -the -building -in 'facing 'high 'wind -speed. It is also -can 'reduce 'factor failure due 10 the extreme wind in Malaysia. 2010-11 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/2566/1/HAMIZAH_BT_JASMI.PDF Hamizah, Jasmi (2010) Determination of direction factor, Md for MS1553:2002 wind loading for building structure. Faculty of Civil Engineering & Earth Resources , Universiti Malaysia Pahang .
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TH Building construction
spellingShingle TH Building construction
Hamizah, Jasmi
Determination of direction factor, Md for MS1553:2002 wind loading for building structure
description Current records from the Malaysia natural disaster studies show that windstorm -causes damages to building. Even though Malaysia has developed 'own code of -practice on wind loading for building structure to support MalaysianStandard -in 2002, ongoing research is still being carried out to update the data in the codes Currently, in Malaysia is refer to Malaysian Standard, MS 15532002 that do not have -the value -of-direction factor, 'Ma. Most -of'design methods in Malaysia are not considering-the effect of wind direction.. .Significantly; .buil'ding orientation on design stage can reduce the wind load impact. Wind speeds data from eights Meteorological Station over the peninsular Malaysia are used in this study. 'Extreme wind speed are -examined by -statistical 'technique -namely -Gumbel method. The 'extreme wind 'speed -data are considered into Iwo conditions, i) Non-Direction Method,(ii) Directional' Method. By using this method extreme wind can be determined at 8 stations in Peninsular 'Malaysia Which are Kuantan, KuaiaTerengganu, 'Mersing, Senal, Subang, -Bayan -Lepas, 'chuping, and Melaka. -From -the 'result, -the 'direction -factor, NTd station was found and the values are recommending in MS 1553:2002. The results also have shown that, at some direction of extreme wind predicted stronger than non direction method. Furthermore 'these values can give guideline 'to The designer to 'orientate -the -building -in 'facing 'high 'wind -speed. It is also -can 'reduce 'factor failure due 10 the extreme wind in Malaysia.
format Undergraduates Project Papers
author Hamizah, Jasmi
author_facet Hamizah, Jasmi
author_sort Hamizah, Jasmi
title Determination of direction factor, Md for MS1553:2002 wind loading for building structure
title_short Determination of direction factor, Md for MS1553:2002 wind loading for building structure
title_full Determination of direction factor, Md for MS1553:2002 wind loading for building structure
title_fullStr Determination of direction factor, Md for MS1553:2002 wind loading for building structure
title_full_unstemmed Determination of direction factor, Md for MS1553:2002 wind loading for building structure
title_sort determination of direction factor, md for ms1553:2002 wind loading for building structure
publishDate 2010
url http://umpir.ump.edu.my/id/eprint/2566/
http://umpir.ump.edu.my/id/eprint/2566/1/HAMIZAH_BT_JASMI.PDF
first_indexed 2023-09-18T21:56:29Z
last_indexed 2023-09-18T21:56:29Z
_version_ 1777414113320763392