Design of valveless micropump using preliminary characteristics from fluid flow

The need for cooling in advance thermal systems is ever in demand. The administration of such cooling will need miniaturization of the current pumping system for small-scale use. A valve less pump is one of the methods to create a small microscale flowrate pump. It has intake and outlet on the same...

Full description

Bibliographic Details
Main Authors: D., Ramasamy, Mahendran, Samykano, Z. A. A., Karim, Nagarajan, T.
Format: Article
Language:English
Published: Asian Network for Scientific Information 2011
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/24990/
http://umpir.ump.edu.my/id/eprint/24990/
http://umpir.ump.edu.my/id/eprint/24990/
http://umpir.ump.edu.my/id/eprint/24990/1/Design%20of%20valveless%20micropump%20using%20preliminary%20characteristics%20from%20fluid%20flow.pdf
id ump-24990
recordtype eprints
spelling ump-249902019-05-30T04:30:24Z http://umpir.ump.edu.my/id/eprint/24990/ Design of valveless micropump using preliminary characteristics from fluid flow D., Ramasamy Mahendran, Samykano Z. A. A., Karim Nagarajan, T. TJ Mechanical engineering and machinery The need for cooling in advance thermal systems is ever in demand. The administration of such cooling will need miniaturization of the current pumping system for small-scale use. A valve less pump is one of the methods to create a small microscale flowrate pump. It has intake and outlet on the same side. Advances in fluid mechanics are able to capture the working principles of such pumps and give a close approximation of the pump characteristics. The fundamental aspect that a micropump will endure is analyzed from fluid mechanics analysis, is a key in the development of the model. The sizing and criteria of the pump is set based on fluid equations of mass, momentum and energy. A design is laid out by using computer-aided design (CAD) based on the voltage frequency that will be applied to the piezomaterial. The movement of the material due to current will cause the fluid to move, as the material will act as a diaphragm. The design is then analyzed using computational fluid dynamics (CFD) from the frequency inputs and a steady flow design is simulated. The reading of the small flowrate is analyzed and a proper method of designing the valve less pump is gathered. Asian Network for Scientific Information 2011 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/24990/1/Design%20of%20valveless%20micropump%20using%20preliminary%20characteristics%20from%20fluid%20flow.pdf D., Ramasamy and Mahendran, Samykano and Z. A. A., Karim and Nagarajan, T. (2011) Design of valveless micropump using preliminary characteristics from fluid flow. Journal of Applied Sciences, 11 (11). pp. 2072-2075. ISSN 1812-5654 http://dx.doi.org/10.3923/jas.2011.2072.2075 http://dx.doi.org/10.3923/jas.2011.2072.2075
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
D., Ramasamy
Mahendran, Samykano
Z. A. A., Karim
Nagarajan, T.
Design of valveless micropump using preliminary characteristics from fluid flow
description The need for cooling in advance thermal systems is ever in demand. The administration of such cooling will need miniaturization of the current pumping system for small-scale use. A valve less pump is one of the methods to create a small microscale flowrate pump. It has intake and outlet on the same side. Advances in fluid mechanics are able to capture the working principles of such pumps and give a close approximation of the pump characteristics. The fundamental aspect that a micropump will endure is analyzed from fluid mechanics analysis, is a key in the development of the model. The sizing and criteria of the pump is set based on fluid equations of mass, momentum and energy. A design is laid out by using computer-aided design (CAD) based on the voltage frequency that will be applied to the piezomaterial. The movement of the material due to current will cause the fluid to move, as the material will act as a diaphragm. The design is then analyzed using computational fluid dynamics (CFD) from the frequency inputs and a steady flow design is simulated. The reading of the small flowrate is analyzed and a proper method of designing the valve less pump is gathered.
format Article
author D., Ramasamy
Mahendran, Samykano
Z. A. A., Karim
Nagarajan, T.
author_facet D., Ramasamy
Mahendran, Samykano
Z. A. A., Karim
Nagarajan, T.
author_sort D., Ramasamy
title Design of valveless micropump using preliminary characteristics from fluid flow
title_short Design of valveless micropump using preliminary characteristics from fluid flow
title_full Design of valveless micropump using preliminary characteristics from fluid flow
title_fullStr Design of valveless micropump using preliminary characteristics from fluid flow
title_full_unstemmed Design of valveless micropump using preliminary characteristics from fluid flow
title_sort design of valveless micropump using preliminary characteristics from fluid flow
publisher Asian Network for Scientific Information
publishDate 2011
url http://umpir.ump.edu.my/id/eprint/24990/
http://umpir.ump.edu.my/id/eprint/24990/
http://umpir.ump.edu.my/id/eprint/24990/
http://umpir.ump.edu.my/id/eprint/24990/1/Design%20of%20valveless%20micropump%20using%20preliminary%20characteristics%20from%20fluid%20flow.pdf
first_indexed 2023-09-18T22:38:08Z
last_indexed 2023-09-18T22:38:08Z
_version_ 1777416733608378368