Heart rate monitoring system based on power line communication

Nowadays, Power Line Communication (PLC) using pre-established Power Lines (PL) becomes more attractive for high data transmission technology. With the development of this technology utilizing distribution line, the medical data such as human Heart Rate (HR) can be transmitted over the power line ch...

Full description

Bibliographic Details
Main Authors: C., Sridhathan, Haidar, Ahmed M. A.
Format: Conference or Workshop Item
Language:English
Published: IEEE 2011
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/24807/
http://umpir.ump.edu.my/id/eprint/24807/
http://umpir.ump.edu.my/id/eprint/24807/1/Heart%20rate%20monitoring%20system%20based%20on%20power%20line%20communication.pdf
id ump-24807
recordtype eprints
spelling ump-248072019-10-23T03:35:42Z http://umpir.ump.edu.my/id/eprint/24807/ Heart rate monitoring system based on power line communication C., Sridhathan Haidar, Ahmed M. A. TK Electrical engineering. Electronics Nuclear engineering Nowadays, Power Line Communication (PLC) using pre-established Power Lines (PL) becomes more attractive for high data transmission technology. With the development of this technology utilizing distribution line, the medical data such as human Heart Rate (HR) can be transmitted over the power line channel. This paper presents a case study of HR Monitoring System (HRMS) involving the use of PLC as a channel to transfer the patient HR measured by Pulse Oximetry (PO). The collected data from the hospital will be stored in the system. The transmission of data on PLC is achieved by using Orthogonal Frequency Division Multiplexing (OFDM). The performance of the above techniques is evaluated based on the Bit Error Rate (BER). IEEE 2011 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/24807/1/Heart%20rate%20monitoring%20system%20based%20on%20power%20line%20communication.pdf C., Sridhathan and Haidar, Ahmed M. A. (2011) Heart rate monitoring system based on power line communication. In: IEEE Conference on Sustainable Utilization Development in Engineering and Technology, STUDENT 2011, 20-21 October 2011 , Semenyih, Selangor. pp. 59-62.. ISBN 978-1-4577-0444-4 https://doi.org/10.1109/STUDENT.2011.6089325
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
C., Sridhathan
Haidar, Ahmed M. A.
Heart rate monitoring system based on power line communication
description Nowadays, Power Line Communication (PLC) using pre-established Power Lines (PL) becomes more attractive for high data transmission technology. With the development of this technology utilizing distribution line, the medical data such as human Heart Rate (HR) can be transmitted over the power line channel. This paper presents a case study of HR Monitoring System (HRMS) involving the use of PLC as a channel to transfer the patient HR measured by Pulse Oximetry (PO). The collected data from the hospital will be stored in the system. The transmission of data on PLC is achieved by using Orthogonal Frequency Division Multiplexing (OFDM). The performance of the above techniques is evaluated based on the Bit Error Rate (BER).
format Conference or Workshop Item
author C., Sridhathan
Haidar, Ahmed M. A.
author_facet C., Sridhathan
Haidar, Ahmed M. A.
author_sort C., Sridhathan
title Heart rate monitoring system based on power line communication
title_short Heart rate monitoring system based on power line communication
title_full Heart rate monitoring system based on power line communication
title_fullStr Heart rate monitoring system based on power line communication
title_full_unstemmed Heart rate monitoring system based on power line communication
title_sort heart rate monitoring system based on power line communication
publisher IEEE
publishDate 2011
url http://umpir.ump.edu.my/id/eprint/24807/
http://umpir.ump.edu.my/id/eprint/24807/
http://umpir.ump.edu.my/id/eprint/24807/1/Heart%20rate%20monitoring%20system%20based%20on%20power%20line%20communication.pdf
first_indexed 2023-09-18T22:37:46Z
last_indexed 2023-09-18T22:37:46Z
_version_ 1777416710487277568