Optimum gas turbine configuration for improving the performance of combined cycle power plant

The thermodynamic analysis of combined cycle gas turbine with effect different configuration for gas turbine are presented and discussed in this paper. The effects of ambient temperature and compression ratio have been proposed to select optimum configuration for gas turbine and its effect on CCGT p...

Full description

Bibliographic Details
Main Authors: Ibrahim, Thamir K., M. M., Rahman, Abdalla, Ahmed N.
Format: Article
Language:English
Published: Elsevier Ltd 2011
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/24789/
http://umpir.ump.edu.my/id/eprint/24789/
http://umpir.ump.edu.my/id/eprint/24789/
http://umpir.ump.edu.my/id/eprint/24789/1/Optimum%20gas%20turbine%20configuration%20for%20improving%20the%20performance%20of%20combined%20cycle%20power%20plant.pdf
id ump-24789
recordtype eprints
spelling ump-247892019-06-12T04:22:14Z http://umpir.ump.edu.my/id/eprint/24789/ Optimum gas turbine configuration for improving the performance of combined cycle power plant Ibrahim, Thamir K. M. M., Rahman Abdalla, Ahmed N. TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering The thermodynamic analysis of combined cycle gas turbine with effect different configuration for gas turbine are presented and discussed in this paper. The effects of ambient temperature and compression ratio have been proposed to select optimum configuration for gas turbine and its effect on CCGT performance. The analysis performance code has been performed used the MATLAB software. The simulating code for gas turbine configuration results show that the simple gas turbine configuration is more suitable with regards to power output, but the regenerative gas turbine configuration has higher efficiency with effect ambient temperature. The simple gas turbine configuration has higher power output with effect the compression ratio, while the regenerative gas turbine configuration has higher efficiency with effect lower compression ratio, therefore the variation of total power output is insignificance at lower compression ratio. The extensive modelling performed in this study reveals that, the ambient temperature and compression ratios are strongly influence on the performance of combined cycle, a higher overall efficiency can be achieved for combined cycle with add regenerative to topping cycle. Elsevier Ltd 2011 Article PeerReviewed pdf en cc_by_nc_nd http://umpir.ump.edu.my/id/eprint/24789/1/Optimum%20gas%20turbine%20configuration%20for%20improving%20the%20performance%20of%20combined%20cycle%20power%20plant.pdf Ibrahim, Thamir K. and M. M., Rahman and Abdalla, Ahmed N. (2011) Optimum gas turbine configuration for improving the performance of combined cycle power plant. Procedia Engineering, 15. pp. 4216-4223. ISSN 1877-7058 https://doi.org/10.1016/j.proeng.2011.08.791 https://doi.org/10.1016/j.proeng.2011.08.791
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
Ibrahim, Thamir K.
M. M., Rahman
Abdalla, Ahmed N.
Optimum gas turbine configuration for improving the performance of combined cycle power plant
description The thermodynamic analysis of combined cycle gas turbine with effect different configuration for gas turbine are presented and discussed in this paper. The effects of ambient temperature and compression ratio have been proposed to select optimum configuration for gas turbine and its effect on CCGT performance. The analysis performance code has been performed used the MATLAB software. The simulating code for gas turbine configuration results show that the simple gas turbine configuration is more suitable with regards to power output, but the regenerative gas turbine configuration has higher efficiency with effect ambient temperature. The simple gas turbine configuration has higher power output with effect the compression ratio, while the regenerative gas turbine configuration has higher efficiency with effect lower compression ratio, therefore the variation of total power output is insignificance at lower compression ratio. The extensive modelling performed in this study reveals that, the ambient temperature and compression ratios are strongly influence on the performance of combined cycle, a higher overall efficiency can be achieved for combined cycle with add regenerative to topping cycle.
format Article
author Ibrahim, Thamir K.
M. M., Rahman
Abdalla, Ahmed N.
author_facet Ibrahim, Thamir K.
M. M., Rahman
Abdalla, Ahmed N.
author_sort Ibrahim, Thamir K.
title Optimum gas turbine configuration for improving the performance of combined cycle power plant
title_short Optimum gas turbine configuration for improving the performance of combined cycle power plant
title_full Optimum gas turbine configuration for improving the performance of combined cycle power plant
title_fullStr Optimum gas turbine configuration for improving the performance of combined cycle power plant
title_full_unstemmed Optimum gas turbine configuration for improving the performance of combined cycle power plant
title_sort optimum gas turbine configuration for improving the performance of combined cycle power plant
publisher Elsevier Ltd
publishDate 2011
url http://umpir.ump.edu.my/id/eprint/24789/
http://umpir.ump.edu.my/id/eprint/24789/
http://umpir.ump.edu.my/id/eprint/24789/
http://umpir.ump.edu.my/id/eprint/24789/1/Optimum%20gas%20turbine%20configuration%20for%20improving%20the%20performance%20of%20combined%20cycle%20power%20plant.pdf
first_indexed 2023-09-18T22:37:43Z
last_indexed 2023-09-18T22:37:43Z
_version_ 1777416707861643264