Energy efficiency analysis in office building through thermal modelling

Malaysia is hot and humid country with high temperature and humidity. The air conditioning systems that have huge energy consumption are an essential component in daily life. The aims of this research are to build a building thermal HVAC model, which could predict the amount of energy consumption re...

Full description

Bibliographic Details
Main Authors: Chen, James Lau Tze, Azizuddin, Abd Aziz, A. N., Oumer, Mohd Hazwan, Yusof
Format: Conference or Workshop Item
Language:English
Published: IOP Publishing Ltd 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/24461/
http://umpir.ump.edu.my/id/eprint/24461/
http://umpir.ump.edu.my/id/eprint/24461/1/Energy%20efficiency%20analysis%20in%20office%20building%20through%20thermal%20modelling.pdf
id ump-24461
recordtype eprints
spelling ump-244612019-10-04T02:43:31Z http://umpir.ump.edu.my/id/eprint/24461/ Energy efficiency analysis in office building through thermal modelling Chen, James Lau Tze Azizuddin, Abd Aziz A. N., Oumer Mohd Hazwan, Yusof TJ Mechanical engineering and machinery Malaysia is hot and humid country with high temperature and humidity. The air conditioning systems that have huge energy consumption are an essential component in daily life. The aims of this research are to build a building thermal HVAC model, which could predict the amount of energy consumption required to get the comfort level using eQUEST and purpose energy saving methods. In the model the different physical properties of the building, weather, and internal load, HVAC system, operating strategies and schedules taken to account. From the result, huge energy used for space cooling resulting low room temperature outside the range of Malaysian Standard MS1525. Among the purposed method, packaged VAV DX coil air conditioning system has the most energy saving on the building’s overall energy consumption following by roof and wall insulation (24°C) indoor temperature, standard VAV CW coil air conditioning system, and daylight control with low e glass. The energy reduction range from 6.0% to 21.2%. This study are significant to study and improve the building energy efficiency. IOP Publishing Ltd 2019-01 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/24461/1/Energy%20efficiency%20analysis%20in%20office%20building%20through%20thermal%20modelling.pdf Chen, James Lau Tze and Azizuddin, Abd Aziz and A. N., Oumer and Mohd Hazwan, Yusof (2019) Energy efficiency analysis in office building through thermal modelling. In: 1st International Postgraduate Conference on Mechanical Engineering, IPCME 2018, 31 October 2018 , Universiti Malaysia Pahang, Pekan, Pahang. pp. 1-11., 469 (1). ISSN 1757-8981 https://doi.org/10.1088/1757-899X/469/1/012010
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Chen, James Lau Tze
Azizuddin, Abd Aziz
A. N., Oumer
Mohd Hazwan, Yusof
Energy efficiency analysis in office building through thermal modelling
description Malaysia is hot and humid country with high temperature and humidity. The air conditioning systems that have huge energy consumption are an essential component in daily life. The aims of this research are to build a building thermal HVAC model, which could predict the amount of energy consumption required to get the comfort level using eQUEST and purpose energy saving methods. In the model the different physical properties of the building, weather, and internal load, HVAC system, operating strategies and schedules taken to account. From the result, huge energy used for space cooling resulting low room temperature outside the range of Malaysian Standard MS1525. Among the purposed method, packaged VAV DX coil air conditioning system has the most energy saving on the building’s overall energy consumption following by roof and wall insulation (24°C) indoor temperature, standard VAV CW coil air conditioning system, and daylight control with low e glass. The energy reduction range from 6.0% to 21.2%. This study are significant to study and improve the building energy efficiency.
format Conference or Workshop Item
author Chen, James Lau Tze
Azizuddin, Abd Aziz
A. N., Oumer
Mohd Hazwan, Yusof
author_facet Chen, James Lau Tze
Azizuddin, Abd Aziz
A. N., Oumer
Mohd Hazwan, Yusof
author_sort Chen, James Lau Tze
title Energy efficiency analysis in office building through thermal modelling
title_short Energy efficiency analysis in office building through thermal modelling
title_full Energy efficiency analysis in office building through thermal modelling
title_fullStr Energy efficiency analysis in office building through thermal modelling
title_full_unstemmed Energy efficiency analysis in office building through thermal modelling
title_sort energy efficiency analysis in office building through thermal modelling
publisher IOP Publishing Ltd
publishDate 2019
url http://umpir.ump.edu.my/id/eprint/24461/
http://umpir.ump.edu.my/id/eprint/24461/
http://umpir.ump.edu.my/id/eprint/24461/1/Energy%20efficiency%20analysis%20in%20office%20building%20through%20thermal%20modelling.pdf
first_indexed 2023-09-18T22:37:02Z
last_indexed 2023-09-18T22:37:02Z
_version_ 1777416664620466176