Leak detection in a pipe using fibre bragg grating sensor
Being the main and safest oil and gas transportation method globally, the integrity and condition of pipeline system is very crucial. The offline existing maintenance method might have consumed more time and risky as it does not detect the flaws immediately after it is formed. This paper focused on...
Main Authors: | , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
IOP Publishing
2019
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/24172/ http://umpir.ump.edu.my/id/eprint/24172/ http://umpir.ump.edu.my/id/eprint/24172/1/27.%20Leak%20detection%20in%20a%20pipe%20using%20fibre%20bragg%20grating%20sensor.pdf http://umpir.ump.edu.my/id/eprint/24172/2/27.1%20Leak%20detection%20in%20a%20pipe%20using%20fibre%20bragg%20grating%20sensor.pdf |
id |
ump-24172 |
---|---|
recordtype |
eprints |
spelling |
ump-241722019-08-02T00:58:43Z http://umpir.ump.edu.my/id/eprint/24172/ Leak detection in a pipe using fibre bragg grating sensor Miminorazeansuhaila, Loman Z. M., Hafizi TJ Mechanical engineering and machinery Being the main and safest oil and gas transportation method globally, the integrity and condition of pipeline system is very crucial. The offline existing maintenance method might have consumed more time and risky as it does not detect the flaws immediately after it is formed. This paper focused on the detection of the leak detection in pipes using the Fiber Bragg Grating pressure transducer. Two different sizes of artificial leak were introduced on the pipe in order to measure the applicability of the FBG sensor in detecting the leak in a pipe. Findings showed that bigger leak size contributed to higher voltage drop in the pipe. This study shows that FBG is a reliable method to be utilised in leak detection because it is very sensitive towards pressure changes in pipe. The results also showed that FBG exhibits good uniformity. IOP Publishing 2019-01 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/24172/1/27.%20Leak%20detection%20in%20a%20pipe%20using%20fibre%20bragg%20grating%20sensor.pdf pdf en http://umpir.ump.edu.my/id/eprint/24172/2/27.1%20Leak%20detection%20in%20a%20pipe%20using%20fibre%20bragg%20grating%20sensor.pdf Miminorazeansuhaila, Loman and Z. M., Hafizi (2019) Leak detection in a pipe using fibre bragg grating sensor. In: International Postgraduate Conference On Mechanical Engineering (IPCME), 31 Oktober 2018 , Universiti Malaysia Pahang (UMP) Pekan, Pahang. pp. 1-8., 469 (1). ISSN 17578981 https://iopscience.iop.org/article/10.1088/1757-899X/469/1/012111/pdf |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Miminorazeansuhaila, Loman Z. M., Hafizi Leak detection in a pipe using fibre bragg grating sensor |
description |
Being the main and safest oil and gas transportation method globally, the integrity and condition of pipeline system is very crucial. The offline existing maintenance method might have consumed more time and risky as it does not detect the flaws immediately after it is formed. This paper focused on the detection of the leak detection in pipes using the Fiber Bragg Grating pressure transducer. Two different sizes of artificial leak were introduced on the pipe in order to measure the applicability of the FBG sensor in detecting the leak in a pipe. Findings showed that bigger leak size contributed to higher voltage drop in the pipe. This study shows that FBG is a reliable method to be utilised in leak detection because it is very sensitive towards pressure changes in pipe. The results also showed that FBG exhibits good uniformity. |
format |
Conference or Workshop Item |
author |
Miminorazeansuhaila, Loman Z. M., Hafizi |
author_facet |
Miminorazeansuhaila, Loman Z. M., Hafizi |
author_sort |
Miminorazeansuhaila, Loman |
title |
Leak detection in a pipe using fibre bragg grating sensor |
title_short |
Leak detection in a pipe using fibre bragg grating sensor |
title_full |
Leak detection in a pipe using fibre bragg grating sensor |
title_fullStr |
Leak detection in a pipe using fibre bragg grating sensor |
title_full_unstemmed |
Leak detection in a pipe using fibre bragg grating sensor |
title_sort |
leak detection in a pipe using fibre bragg grating sensor |
publisher |
IOP Publishing |
publishDate |
2019 |
url |
http://umpir.ump.edu.my/id/eprint/24172/ http://umpir.ump.edu.my/id/eprint/24172/ http://umpir.ump.edu.my/id/eprint/24172/1/27.%20Leak%20detection%20in%20a%20pipe%20using%20fibre%20bragg%20grating%20sensor.pdf http://umpir.ump.edu.my/id/eprint/24172/2/27.1%20Leak%20detection%20in%20a%20pipe%20using%20fibre%20bragg%20grating%20sensor.pdf |
first_indexed |
2023-09-18T22:36:27Z |
last_indexed |
2023-09-18T22:36:27Z |
_version_ |
1777416627933937664 |