Effect of processed spent bleaching earth as partial cement replacement on thermal conductivity and porosity of foamed concrete

Foamed concrete is categorized as a lightweight concrete containing air voids. The only difference is that foamed concrete does not contain coarse aggregate in its mixture. Foamed concrete is produced by inducing foam into the slurry of cement mixing with silica sand. In practice, the cement is usua...

Full description

Bibliographic Details
Main Author: Mohammad Asyraf, Mohd Faridi Yusli
Format: Undergraduates Project Papers
Language:English
English
English
English
Published: 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/23802/
http://umpir.ump.edu.my/id/eprint/23802/
http://umpir.ump.edu.my/id/eprint/23802/1/Effect%20of%20processed%20spent%20bleaching%20earth%20as%20partial%20cement%20replacement%20on%20thermal%20conductivity%20and%20porosity%20of%20foamed%20concrete%20-%20Table%20of%20contents.pdf
http://umpir.ump.edu.my/id/eprint/23802/2/Effect%20of%20processed%20spent%20bleaching%20earth%20as%20partial%20cement%20replacement%20on%20thermal%20conductivity%20and%20porosity%20of%20foamed%20concrete%20-%20Abstract.pdf
http://umpir.ump.edu.my/id/eprint/23802/3/Effect%20of%20processed%20spent%20bleaching%20earth%20as%20partial%20cement%20replacement%20on%20thermal%20conductivity%20and%20porosity%20of%20foamed%20concrete%20-%20Chapter%201.pdf
http://umpir.ump.edu.my/id/eprint/23802/4/Effect%20of%20processed%20spent%20bleaching%20earth%20as%20partial%20cement%20replacement%20on%20thermal%20conductivity%20and%20porosity%20of%20foamed%20concrete%20-%20References.pdf
id ump-23802
recordtype eprints
spelling ump-238022019-02-25T04:54:41Z http://umpir.ump.edu.my/id/eprint/23802/ Effect of processed spent bleaching earth as partial cement replacement on thermal conductivity and porosity of foamed concrete Mohammad Asyraf, Mohd Faridi Yusli TA Engineering (General). Civil engineering (General) Foamed concrete is categorized as a lightweight concrete containing air voids. The only difference is that foamed concrete does not contain coarse aggregate in its mixture. Foamed concrete is produced by inducing foam into the slurry of cement mixing with silica sand. In practice, the cement is usually replace with lime. Processed Spent Bleaching Earth (PSBE) is one of the latest Crude Palm Oil (CPO) product. After it has been degummed and bleached, it will come in fine particle and it is classified as a good pozzolanic material. The study investigates the suitability of PSBE as partial cement replacement. The scope of study includes the thermal conductivity and porosity percentage. 10%, 20% and 30% of PSBE will be replacing cement. Foaming agent is used to form air void in foamed concrete. The results turns out that for thermal for 10% PSBE cement replacement at 28 days gets the best reading which is 0.52 W/m.K. For porosity, the result shows that porosity for 30% PSBE foamed concrete achieved the result at 90 days with 17.9% compared to controlled sample. 21.4%. Foamed concrete density also increase when the PSBE percentage increase. Generally thermal conductivity and porosity percentage is one of pozzolanic material characteristic and this study will emphasize this two aspect. 2018-01 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/23802/1/Effect%20of%20processed%20spent%20bleaching%20earth%20as%20partial%20cement%20replacement%20on%20thermal%20conductivity%20and%20porosity%20of%20foamed%20concrete%20-%20Table%20of%20contents.pdf pdf en http://umpir.ump.edu.my/id/eprint/23802/2/Effect%20of%20processed%20spent%20bleaching%20earth%20as%20partial%20cement%20replacement%20on%20thermal%20conductivity%20and%20porosity%20of%20foamed%20concrete%20-%20Abstract.pdf pdf en http://umpir.ump.edu.my/id/eprint/23802/3/Effect%20of%20processed%20spent%20bleaching%20earth%20as%20partial%20cement%20replacement%20on%20thermal%20conductivity%20and%20porosity%20of%20foamed%20concrete%20-%20Chapter%201.pdf pdf en http://umpir.ump.edu.my/id/eprint/23802/4/Effect%20of%20processed%20spent%20bleaching%20earth%20as%20partial%20cement%20replacement%20on%20thermal%20conductivity%20and%20porosity%20of%20foamed%20concrete%20-%20References.pdf Mohammad Asyraf, Mohd Faridi Yusli (2018) Effect of processed spent bleaching earth as partial cement replacement on thermal conductivity and porosity of foamed concrete. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:103623&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
English
English
English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Mohammad Asyraf, Mohd Faridi Yusli
Effect of processed spent bleaching earth as partial cement replacement on thermal conductivity and porosity of foamed concrete
description Foamed concrete is categorized as a lightweight concrete containing air voids. The only difference is that foamed concrete does not contain coarse aggregate in its mixture. Foamed concrete is produced by inducing foam into the slurry of cement mixing with silica sand. In practice, the cement is usually replace with lime. Processed Spent Bleaching Earth (PSBE) is one of the latest Crude Palm Oil (CPO) product. After it has been degummed and bleached, it will come in fine particle and it is classified as a good pozzolanic material. The study investigates the suitability of PSBE as partial cement replacement. The scope of study includes the thermal conductivity and porosity percentage. 10%, 20% and 30% of PSBE will be replacing cement. Foaming agent is used to form air void in foamed concrete. The results turns out that for thermal for 10% PSBE cement replacement at 28 days gets the best reading which is 0.52 W/m.K. For porosity, the result shows that porosity for 30% PSBE foamed concrete achieved the result at 90 days with 17.9% compared to controlled sample. 21.4%. Foamed concrete density also increase when the PSBE percentage increase. Generally thermal conductivity and porosity percentage is one of pozzolanic material characteristic and this study will emphasize this two aspect.
format Undergraduates Project Papers
author Mohammad Asyraf, Mohd Faridi Yusli
author_facet Mohammad Asyraf, Mohd Faridi Yusli
author_sort Mohammad Asyraf, Mohd Faridi Yusli
title Effect of processed spent bleaching earth as partial cement replacement on thermal conductivity and porosity of foamed concrete
title_short Effect of processed spent bleaching earth as partial cement replacement on thermal conductivity and porosity of foamed concrete
title_full Effect of processed spent bleaching earth as partial cement replacement on thermal conductivity and porosity of foamed concrete
title_fullStr Effect of processed spent bleaching earth as partial cement replacement on thermal conductivity and porosity of foamed concrete
title_full_unstemmed Effect of processed spent bleaching earth as partial cement replacement on thermal conductivity and porosity of foamed concrete
title_sort effect of processed spent bleaching earth as partial cement replacement on thermal conductivity and porosity of foamed concrete
publishDate 2018
url http://umpir.ump.edu.my/id/eprint/23802/
http://umpir.ump.edu.my/id/eprint/23802/
http://umpir.ump.edu.my/id/eprint/23802/1/Effect%20of%20processed%20spent%20bleaching%20earth%20as%20partial%20cement%20replacement%20on%20thermal%20conductivity%20and%20porosity%20of%20foamed%20concrete%20-%20Table%20of%20contents.pdf
http://umpir.ump.edu.my/id/eprint/23802/2/Effect%20of%20processed%20spent%20bleaching%20earth%20as%20partial%20cement%20replacement%20on%20thermal%20conductivity%20and%20porosity%20of%20foamed%20concrete%20-%20Abstract.pdf
http://umpir.ump.edu.my/id/eprint/23802/3/Effect%20of%20processed%20spent%20bleaching%20earth%20as%20partial%20cement%20replacement%20on%20thermal%20conductivity%20and%20porosity%20of%20foamed%20concrete%20-%20Chapter%201.pdf
http://umpir.ump.edu.my/id/eprint/23802/4/Effect%20of%20processed%20spent%20bleaching%20earth%20as%20partial%20cement%20replacement%20on%20thermal%20conductivity%20and%20porosity%20of%20foamed%20concrete%20-%20References.pdf
first_indexed 2023-09-18T22:35:49Z
last_indexed 2023-09-18T22:35:49Z
_version_ 1777416587794448384