Impact of overcurrent protection coordination on the location of the distributed generation sources
In presence of the Distributed Generation (DG) brought new chal-lenges to the protection engineers since novel coordination scheme is no longer appropriate with the penetration of the DG. The extreme case is violation to the primary and backup relay selectivity constraint. This violation will have r...
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
2018
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/22925/ http://umpir.ump.edu.my/id/eprint/22925/1/61.%20Impact%20of%20overcurrent%20protection%20coordination%20on%20the%20location.pdf http://umpir.ump.edu.my/id/eprint/22925/2/61.1%20Impact%20of%20overcurrent%20protection%20coordination%20on%20the%20location.pdf |
id |
ump-22925 |
---|---|
recordtype |
eprints |
spelling |
ump-229252019-01-22T06:58:58Z http://umpir.ump.edu.my/id/eprint/22925/ Impact of overcurrent protection coordination on the location of the distributed generation sources Noor Zaihah, Jamal M. H., Sulaiman Omar, Aliman TK Electrical engineering. Electronics Nuclear engineering In presence of the Distributed Generation (DG) brought new chal-lenges to the protection engineers since novel coordination scheme is no longer appropriate with the penetration of the DG. The extreme case is violation to the primary and backup relay selectivity constraint. This violation will have resulted to the degradation of the relay performance. Therefore, this paper proposes the best location of the DG penetration to decrease the effect of the DG presentation to the relay performance using the grey wolf optimization (GWO) algorithm. The impacts of the DG prior to the location of the insertion are implemented to the radial 7 bus test system. As a consequence, the best location of the DG penetra-tion is then identified. 2018 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/22925/1/61.%20Impact%20of%20overcurrent%20protection%20coordination%20on%20the%20location.pdf pdf en http://umpir.ump.edu.my/id/eprint/22925/2/61.1%20Impact%20of%20overcurrent%20protection%20coordination%20on%20the%20location.pdf Noor Zaihah, Jamal and M. H., Sulaiman and Omar, Aliman (2018) Impact of overcurrent protection coordination on the location of the distributed generation sources. In: 10th National Technical Seminar on Underwater System Technology (NUSYS) 2018, 26-27 September 2018 , Universiti Malaysia Pahang, Pekan. pp. 1-8.. |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Noor Zaihah, Jamal M. H., Sulaiman Omar, Aliman Impact of overcurrent protection coordination on the location of the distributed generation sources |
description |
In presence of the Distributed Generation (DG) brought new chal-lenges to the protection engineers since novel coordination scheme is no longer appropriate with the penetration of the DG. The extreme case is violation to the primary and backup relay selectivity constraint. This violation will have resulted to the degradation of the relay performance. Therefore, this paper proposes the best location of the DG penetration to decrease the effect of the DG presentation to the relay performance using the grey wolf optimization (GWO) algorithm. The impacts of the DG prior to the location of the insertion are implemented to the radial 7 bus test system. As a consequence, the best location of the DG penetra-tion is then identified. |
format |
Conference or Workshop Item |
author |
Noor Zaihah, Jamal M. H., Sulaiman Omar, Aliman |
author_facet |
Noor Zaihah, Jamal M. H., Sulaiman Omar, Aliman |
author_sort |
Noor Zaihah, Jamal |
title |
Impact of overcurrent protection coordination on the location of the distributed generation sources |
title_short |
Impact of overcurrent protection coordination on the location of the distributed generation sources |
title_full |
Impact of overcurrent protection coordination on the location of the distributed generation sources |
title_fullStr |
Impact of overcurrent protection coordination on the location of the distributed generation sources |
title_full_unstemmed |
Impact of overcurrent protection coordination on the location of the distributed generation sources |
title_sort |
impact of overcurrent protection coordination on the location of the distributed generation sources |
publishDate |
2018 |
url |
http://umpir.ump.edu.my/id/eprint/22925/ http://umpir.ump.edu.my/id/eprint/22925/1/61.%20Impact%20of%20overcurrent%20protection%20coordination%20on%20the%20location.pdf http://umpir.ump.edu.my/id/eprint/22925/2/61.1%20Impact%20of%20overcurrent%20protection%20coordination%20on%20the%20location.pdf |
first_indexed |
2023-09-18T22:34:06Z |
last_indexed |
2023-09-18T22:34:06Z |
_version_ |
1777416480505200640 |