Fault identification in pipeline system using normalized hilbert huang transform and automatic selection of intrinsic mode function

Pressure transient analysis have been widely studied for monitoring of pipeline healthy and condition assessment in water distribution systems. This technique has potential low cost, non intrusive nature and able to locate any uncertainties (leak, pipe fitting, blockage) at greater distance from mea...

Full description

Bibliographic Details
Main Authors: Hanafi, M. Yusop, M. F., Ghazali, M. F. M., Yusof, M. A., Pi Remli
Format: Conference or Workshop Item
Language:English
English
Published: EDP Sciences 2018
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/22105/
http://umpir.ump.edu.my/id/eprint/22105/
http://umpir.ump.edu.my/id/eprint/22105/1/31.1%20Fault%20identification%20in%20pipeline%20system%20using%20normalized%20hilbert.pdf
http://umpir.ump.edu.my/id/eprint/22105/2/31.1%20Fault%20identification%20in%20pipeline%20system%20using%20normalized%20hilbert.pdf
id ump-22105
recordtype eprints
spelling ump-221052018-12-07T02:11:47Z http://umpir.ump.edu.my/id/eprint/22105/ Fault identification in pipeline system using normalized hilbert huang transform and automatic selection of intrinsic mode function Hanafi, M. Yusop M. F., Ghazali M. F. M., Yusof M. A., Pi Remli TJ Mechanical engineering and machinery Pressure transient analysis have been widely studied for monitoring of pipeline healthy and condition assessment in water distribution systems. This technique has potential low cost, non intrusive nature and able to locate any uncertainties (leak, pipe fitting, blockage) at greater distance from measurement point. In this research the application of Normalised Hilbert Huang Transform (NHHT) as the method to analyse the pressure transient signal. However, this method has the difficulty in selecting the suitable IMF for the further data analysing method which is Normalised Hilbert Transform (NHT). This paper proposed to apply Integrated Kurtosis-based Algorithm for z-filter Technique (Ikaz) for that allows automatic selection of intrinsic mode function (IMF) that’s should be used. This work demonstrates on 67.9-meter Medium High Density Poly Ethylene (MDPE) pipe installed with single artificial leak simulator with water pressure about 1-4 bar. The analysis results using Normalized Ikaz proven that the method can be apply as an automatic selection of intrinsic mode function (IMF) although the noise level ratio of the signal is lower. Normalized Ikaz is recommended and advised to be implemented as automatic selection of intrinsic mode function (IMF) through NHHT analysis. EDP Sciences 2018-04 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/22105/1/31.1%20Fault%20identification%20in%20pipeline%20system%20using%20normalized%20hilbert.pdf pdf en http://umpir.ump.edu.my/id/eprint/22105/2/31.1%20Fault%20identification%20in%20pipeline%20system%20using%20normalized%20hilbert.pdf Hanafi, M. Yusop and M. F., Ghazali and M. F. M., Yusof and M. A., Pi Remli (2018) Fault identification in pipeline system using normalized hilbert huang transform and automatic selection of intrinsic mode function. In: MATEC Web of Conferences: 3rd International Conference on Design and Manufacturing Engineering, ICDME 2018, 16 - 18 July 2018 , Monash University, Melbourne, Australia. pp. 1-6.. ISSN 2261236X https://www.matec-conferences.org/articles/matecconf/pdf/2018/80/matecconf_icdme2018_02002.pdf
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Hanafi, M. Yusop
M. F., Ghazali
M. F. M., Yusof
M. A., Pi Remli
Fault identification in pipeline system using normalized hilbert huang transform and automatic selection of intrinsic mode function
description Pressure transient analysis have been widely studied for monitoring of pipeline healthy and condition assessment in water distribution systems. This technique has potential low cost, non intrusive nature and able to locate any uncertainties (leak, pipe fitting, blockage) at greater distance from measurement point. In this research the application of Normalised Hilbert Huang Transform (NHHT) as the method to analyse the pressure transient signal. However, this method has the difficulty in selecting the suitable IMF for the further data analysing method which is Normalised Hilbert Transform (NHT). This paper proposed to apply Integrated Kurtosis-based Algorithm for z-filter Technique (Ikaz) for that allows automatic selection of intrinsic mode function (IMF) that’s should be used. This work demonstrates on 67.9-meter Medium High Density Poly Ethylene (MDPE) pipe installed with single artificial leak simulator with water pressure about 1-4 bar. The analysis results using Normalized Ikaz proven that the method can be apply as an automatic selection of intrinsic mode function (IMF) although the noise level ratio of the signal is lower. Normalized Ikaz is recommended and advised to be implemented as automatic selection of intrinsic mode function (IMF) through NHHT analysis.
format Conference or Workshop Item
author Hanafi, M. Yusop
M. F., Ghazali
M. F. M., Yusof
M. A., Pi Remli
author_facet Hanafi, M. Yusop
M. F., Ghazali
M. F. M., Yusof
M. A., Pi Remli
author_sort Hanafi, M. Yusop
title Fault identification in pipeline system using normalized hilbert huang transform and automatic selection of intrinsic mode function
title_short Fault identification in pipeline system using normalized hilbert huang transform and automatic selection of intrinsic mode function
title_full Fault identification in pipeline system using normalized hilbert huang transform and automatic selection of intrinsic mode function
title_fullStr Fault identification in pipeline system using normalized hilbert huang transform and automatic selection of intrinsic mode function
title_full_unstemmed Fault identification in pipeline system using normalized hilbert huang transform and automatic selection of intrinsic mode function
title_sort fault identification in pipeline system using normalized hilbert huang transform and automatic selection of intrinsic mode function
publisher EDP Sciences
publishDate 2018
url http://umpir.ump.edu.my/id/eprint/22105/
http://umpir.ump.edu.my/id/eprint/22105/
http://umpir.ump.edu.my/id/eprint/22105/1/31.1%20Fault%20identification%20in%20pipeline%20system%20using%20normalized%20hilbert.pdf
http://umpir.ump.edu.my/id/eprint/22105/2/31.1%20Fault%20identification%20in%20pipeline%20system%20using%20normalized%20hilbert.pdf
first_indexed 2023-09-18T22:32:43Z
last_indexed 2023-09-18T22:32:43Z
_version_ 1777416393073885184