Permeability and selectivity study of polysulfone membrane for gas separation

Polysulfone (PSU) membrane is one of the economical and potential membranes to be used in gas separation process. Polysulfone flat sheet membrane were fabricated from 22.0 wt% polysulfone, 31.8 wt% N,N-dimethylformamide, 31.8 wt% tetrahydofuran and 14.4 wt% ethanol using dry/wet phase inversion proc...

Full description

Bibliographic Details
Main Author: Farhana, Hasbullah
Format: Undergraduates Project Papers
Language:English
English
English
English
Published: 2009
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/21872/
http://umpir.ump.edu.my/id/eprint/21872/
http://umpir.ump.edu.my/id/eprint/21872/1/Permeability%20and%20selectivity%20study%20of%20polysulfone%20membrane%20for%20gas%20separation%20-%20Table%20of%20contents.pdf
http://umpir.ump.edu.my/id/eprint/21872/2/Permeability%20and%20selectivity%20study%20of%20polysulfone%20membrane%20for%20gas%20separation%20-%20Abstract.pdf
http://umpir.ump.edu.my/id/eprint/21872/3/Permeability%20and%20selectivity%20study%20of%20polysulfone%20membrane%20for%20gas%20separation%20-%20Chapter%201.pdf
http://umpir.ump.edu.my/id/eprint/21872/4/Permeability%20and%20selectivity%20study%20of%20polysulfone%20membrane%20for%20gas%20separation%20-%20References.pdf
id ump-21872
recordtype eprints
spelling ump-218722018-09-14T03:58:07Z http://umpir.ump.edu.my/id/eprint/21872/ Permeability and selectivity study of polysulfone membrane for gas separation Farhana, Hasbullah TP Chemical technology Polysulfone (PSU) membrane is one of the economical and potential membranes to be used in gas separation process. Polysulfone flat sheet membrane were fabricated from 22.0 wt% polysulfone, 31.8 wt% N,N-dimethylformamide, 31.8 wt% tetrahydofuran and 14.4 wt% ethanol using dry/wet phase inversion process. Eight different samples were tested. The permeability of the membranes were tested using the gas permeation unit with pressure of 1.5-2.5 bar and were tested with CO2, CH4, N2 and also O2. Among all these eight types of membrane tested, several show that the behavior of polysulfone membrane to permeate CO2 relies on the treatment that the membranes undergo and the temperature of the coagulation bath. Thus, the most excellent value of permeability for CO2 among eight types of membranes tested was 4.98 x 10-3 cm3/cm2.s.cmHg which was PSU membrane immersed in a 4°C coagulation bath and treated with polydimethylsiloxane (PDMS) as a coating agent with the selectivity value of 1.36.From the data and result collected it is to be proved that temperature of coagulation bath and also the coating agent for membrane treatment play a major role in affecting PSU membrane permeability and selectivity as a whole. 2009-04 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/21872/1/Permeability%20and%20selectivity%20study%20of%20polysulfone%20membrane%20for%20gas%20separation%20-%20Table%20of%20contents.pdf pdf en http://umpir.ump.edu.my/id/eprint/21872/2/Permeability%20and%20selectivity%20study%20of%20polysulfone%20membrane%20for%20gas%20separation%20-%20Abstract.pdf pdf en http://umpir.ump.edu.my/id/eprint/21872/3/Permeability%20and%20selectivity%20study%20of%20polysulfone%20membrane%20for%20gas%20separation%20-%20Chapter%201.pdf pdf en http://umpir.ump.edu.my/id/eprint/21872/4/Permeability%20and%20selectivity%20study%20of%20polysulfone%20membrane%20for%20gas%20separation%20-%20References.pdf Farhana, Hasbullah (2009) Permeability and selectivity study of polysulfone membrane for gas separation. Faculty of Chemical & Natural Resources Engineering, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:45128&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
English
English
English
topic TP Chemical technology
spellingShingle TP Chemical technology
Farhana, Hasbullah
Permeability and selectivity study of polysulfone membrane for gas separation
description Polysulfone (PSU) membrane is one of the economical and potential membranes to be used in gas separation process. Polysulfone flat sheet membrane were fabricated from 22.0 wt% polysulfone, 31.8 wt% N,N-dimethylformamide, 31.8 wt% tetrahydofuran and 14.4 wt% ethanol using dry/wet phase inversion process. Eight different samples were tested. The permeability of the membranes were tested using the gas permeation unit with pressure of 1.5-2.5 bar and were tested with CO2, CH4, N2 and also O2. Among all these eight types of membrane tested, several show that the behavior of polysulfone membrane to permeate CO2 relies on the treatment that the membranes undergo and the temperature of the coagulation bath. Thus, the most excellent value of permeability for CO2 among eight types of membranes tested was 4.98 x 10-3 cm3/cm2.s.cmHg which was PSU membrane immersed in a 4°C coagulation bath and treated with polydimethylsiloxane (PDMS) as a coating agent with the selectivity value of 1.36.From the data and result collected it is to be proved that temperature of coagulation bath and also the coating agent for membrane treatment play a major role in affecting PSU membrane permeability and selectivity as a whole.
format Undergraduates Project Papers
author Farhana, Hasbullah
author_facet Farhana, Hasbullah
author_sort Farhana, Hasbullah
title Permeability and selectivity study of polysulfone membrane for gas separation
title_short Permeability and selectivity study of polysulfone membrane for gas separation
title_full Permeability and selectivity study of polysulfone membrane for gas separation
title_fullStr Permeability and selectivity study of polysulfone membrane for gas separation
title_full_unstemmed Permeability and selectivity study of polysulfone membrane for gas separation
title_sort permeability and selectivity study of polysulfone membrane for gas separation
publishDate 2009
url http://umpir.ump.edu.my/id/eprint/21872/
http://umpir.ump.edu.my/id/eprint/21872/
http://umpir.ump.edu.my/id/eprint/21872/1/Permeability%20and%20selectivity%20study%20of%20polysulfone%20membrane%20for%20gas%20separation%20-%20Table%20of%20contents.pdf
http://umpir.ump.edu.my/id/eprint/21872/2/Permeability%20and%20selectivity%20study%20of%20polysulfone%20membrane%20for%20gas%20separation%20-%20Abstract.pdf
http://umpir.ump.edu.my/id/eprint/21872/3/Permeability%20and%20selectivity%20study%20of%20polysulfone%20membrane%20for%20gas%20separation%20-%20Chapter%201.pdf
http://umpir.ump.edu.my/id/eprint/21872/4/Permeability%20and%20selectivity%20study%20of%20polysulfone%20membrane%20for%20gas%20separation%20-%20References.pdf
first_indexed 2023-09-18T22:32:18Z
last_indexed 2023-09-18T22:32:18Z
_version_ 1777416366251311104