Investigation on different types of blood glucose control system

Basically it is a case study on proposed blood glucose protocols. Among the protocols been implemented in Intensive Care Unit or critically ill patients were been studied and the outcome of this project is to propose the suitable blood glucose protocol for critically ill patients in Malaysia. Two ma...

Full description

Bibliographic Details
Main Authors: Gopalakrishnan, Siva, Ummu Kulthum, Jamaludin
Format: Article
Language:English
English
Published: Penerbit UiTM 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/21469/
http://umpir.ump.edu.my/id/eprint/21469/
http://umpir.ump.edu.my/id/eprint/21469/1/Investigation%20on%20Different%20Types%20of%20Blood%20Glucose%20Control%20System.pdf
http://umpir.ump.edu.my/id/eprint/21469/2/9_Vol_4_2_ID104_20.pdf
id ump-21469
recordtype eprints
spelling ump-214692018-09-12T06:29:49Z http://umpir.ump.edu.my/id/eprint/21469/ Investigation on different types of blood glucose control system Gopalakrishnan, Siva Ummu Kulthum, Jamaludin Q Science (General) QA Mathematics R Medicine (General) T Technology (General) TJ Mechanical engineering and machinery Basically it is a case study on proposed blood glucose protocols. Among the protocols been implemented in Intensive Care Unit or critically ill patients were been studied and the outcome of this project is to propose the suitable blood glucose protocol for critically ill patients in Malaysia. Two main protocols known as HTAA and SPRINT been implement in Hospital Tengku Ampuan Afzan Malaysia and Christchurch Hospital, New Zealand respectively. Besides of studying whether both protocols are capable to reduce the mortality rate, these two are compared in terms of patients suitability whether they can adapt to the current protocols or not. Next to find out whether both protocols are same in their goal and the significant level of the patient’s data obtained from both hospitals (HTAA and Christchurch). In order to find out the patients data is significant or not and the goal of the protocols whether similar, some statistical analysis been carried out solidify the hypothesis statement. This is to ensure the outcome statement of proposing the best protocol between HTAA and SPRINT to critically ill patients in Malaysia. Penerbit UiTM 2017-09 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/21469/1/Investigation%20on%20Different%20Types%20of%20Blood%20Glucose%20Control%20System.pdf pdf en http://umpir.ump.edu.my/id/eprint/21469/2/9_Vol_4_2_ID104_20.pdf Gopalakrishnan, Siva and Ummu Kulthum, Jamaludin (2017) Investigation on different types of blood glucose control system. Journal of Mechanical Engineering, SI(4) (2). pp. 135-152. ISSN 1823- 5514 (Print); 2550-164X (Online) http://jmeche.com/wp-content/uploads/bsk-pdf-manager/9_Vol_4_2_ID104_20.pdf
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
English
topic Q Science (General)
QA Mathematics
R Medicine (General)
T Technology (General)
TJ Mechanical engineering and machinery
spellingShingle Q Science (General)
QA Mathematics
R Medicine (General)
T Technology (General)
TJ Mechanical engineering and machinery
Gopalakrishnan, Siva
Ummu Kulthum, Jamaludin
Investigation on different types of blood glucose control system
description Basically it is a case study on proposed blood glucose protocols. Among the protocols been implemented in Intensive Care Unit or critically ill patients were been studied and the outcome of this project is to propose the suitable blood glucose protocol for critically ill patients in Malaysia. Two main protocols known as HTAA and SPRINT been implement in Hospital Tengku Ampuan Afzan Malaysia and Christchurch Hospital, New Zealand respectively. Besides of studying whether both protocols are capable to reduce the mortality rate, these two are compared in terms of patients suitability whether they can adapt to the current protocols or not. Next to find out whether both protocols are same in their goal and the significant level of the patient’s data obtained from both hospitals (HTAA and Christchurch). In order to find out the patients data is significant or not and the goal of the protocols whether similar, some statistical analysis been carried out solidify the hypothesis statement. This is to ensure the outcome statement of proposing the best protocol between HTAA and SPRINT to critically ill patients in Malaysia.
format Article
author Gopalakrishnan, Siva
Ummu Kulthum, Jamaludin
author_facet Gopalakrishnan, Siva
Ummu Kulthum, Jamaludin
author_sort Gopalakrishnan, Siva
title Investigation on different types of blood glucose control system
title_short Investigation on different types of blood glucose control system
title_full Investigation on different types of blood glucose control system
title_fullStr Investigation on different types of blood glucose control system
title_full_unstemmed Investigation on different types of blood glucose control system
title_sort investigation on different types of blood glucose control system
publisher Penerbit UiTM
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/21469/
http://umpir.ump.edu.my/id/eprint/21469/
http://umpir.ump.edu.my/id/eprint/21469/1/Investigation%20on%20Different%20Types%20of%20Blood%20Glucose%20Control%20System.pdf
http://umpir.ump.edu.my/id/eprint/21469/2/9_Vol_4_2_ID104_20.pdf
first_indexed 2023-09-18T22:31:31Z
last_indexed 2023-09-18T22:31:31Z
_version_ 1777416317606821888