Development of the wireless goniometer in measuring range of motion for lower extremities

Human range of motion (ROM) is a measurement of human movement capability in the kinesiology study. To measure ROM a device known as goniometer is used specifically in the joint angle measurement. However, the current measurement is manually measured in static condition was performed by the traditio...

Full description

Bibliographic Details
Main Authors: Zulkifli, Ahmad, Yong, Wong Fei, Mong, Tan Choon, Idris, Mat Sahat, Zakri, Ghazalli
Format: Article
Language:English
Published: Publishing Technology 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/21096/
http://umpir.ump.edu.my/id/eprint/21096/
http://umpir.ump.edu.my/id/eprint/21096/
http://umpir.ump.edu.my/id/eprint/21096/1/Development%20of%20the%20Wireless%20Goniometer%20in%20Measuring%20Range%20of%20Motion%20for%20Lower%20Extremities.pdf
id ump-21096
recordtype eprints
spelling ump-210962019-06-20T03:30:57Z http://umpir.ump.edu.my/id/eprint/21096/ Development of the wireless goniometer in measuring range of motion for lower extremities Zulkifli, Ahmad Yong, Wong Fei Mong, Tan Choon Idris, Mat Sahat Zakri, Ghazalli TJ Mechanical engineering and machinery Human range of motion (ROM) is a measurement of human movement capability in the kinesiology study. To measure ROM a device known as goniometer is used specifically in the joint angle measurement. However, the current measurement is manually measured in static condition was performed by the traditional goniometer device which operated in an analog scale. Therefore, the objective of this project is to develop a wearable electronic goniometer that integrates with Arduino microcontroller that sense and record the motion of patient’s knee wirelessly. Device will display the motion of knee joint angle through Android mobile phone via Bluetooth module either in static or in dynamic conditions. In this case, potentiometer will act as a rotation sensor by interpreting the analog data obtained by Arduino. The potentiometer is attached to patient’s leg will measure the knee joint angle as potentiometer rotated. The knee flexion angle was selected for analyses due to the importance of identifying the knee osteoarthritis problem in the lower extremities. In fact an experiment was conducted on the treadmill under walking condition with 1.5 km/h speed. Results obtained from the device will be compared with the motion analysis data that will be recorded using high speed camera and Kinovea software specifically for angle measurement. It indicates that both methods can be used in determine ROM and the difference between data collected by both methods is just below than 3.4%. Hence, this study is potentially beneficial for the wireless monitoring system that can be applied in the sport and rehabilitation applications. Publishing Technology 2017 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/21096/1/Development%20of%20the%20Wireless%20Goniometer%20in%20Measuring%20Range%20of%20Motion%20for%20Lower%20Extremities.pdf Zulkifli, Ahmad and Yong, Wong Fei and Mong, Tan Choon and Idris, Mat Sahat and Zakri, Ghazalli (2017) Development of the wireless goniometer in measuring range of motion for lower extremities. Advanced Science Letters, 23 (6). pp. 5107-5111. ISSN 1936-6612 https://doi.org/10.1166/asl.2017.7320 doi: 10.1166/asl.2017.7320
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Zulkifli, Ahmad
Yong, Wong Fei
Mong, Tan Choon
Idris, Mat Sahat
Zakri, Ghazalli
Development of the wireless goniometer in measuring range of motion for lower extremities
description Human range of motion (ROM) is a measurement of human movement capability in the kinesiology study. To measure ROM a device known as goniometer is used specifically in the joint angle measurement. However, the current measurement is manually measured in static condition was performed by the traditional goniometer device which operated in an analog scale. Therefore, the objective of this project is to develop a wearable electronic goniometer that integrates with Arduino microcontroller that sense and record the motion of patient’s knee wirelessly. Device will display the motion of knee joint angle through Android mobile phone via Bluetooth module either in static or in dynamic conditions. In this case, potentiometer will act as a rotation sensor by interpreting the analog data obtained by Arduino. The potentiometer is attached to patient’s leg will measure the knee joint angle as potentiometer rotated. The knee flexion angle was selected for analyses due to the importance of identifying the knee osteoarthritis problem in the lower extremities. In fact an experiment was conducted on the treadmill under walking condition with 1.5 km/h speed. Results obtained from the device will be compared with the motion analysis data that will be recorded using high speed camera and Kinovea software specifically for angle measurement. It indicates that both methods can be used in determine ROM and the difference between data collected by both methods is just below than 3.4%. Hence, this study is potentially beneficial for the wireless monitoring system that can be applied in the sport and rehabilitation applications.
format Article
author Zulkifli, Ahmad
Yong, Wong Fei
Mong, Tan Choon
Idris, Mat Sahat
Zakri, Ghazalli
author_facet Zulkifli, Ahmad
Yong, Wong Fei
Mong, Tan Choon
Idris, Mat Sahat
Zakri, Ghazalli
author_sort Zulkifli, Ahmad
title Development of the wireless goniometer in measuring range of motion for lower extremities
title_short Development of the wireless goniometer in measuring range of motion for lower extremities
title_full Development of the wireless goniometer in measuring range of motion for lower extremities
title_fullStr Development of the wireless goniometer in measuring range of motion for lower extremities
title_full_unstemmed Development of the wireless goniometer in measuring range of motion for lower extremities
title_sort development of the wireless goniometer in measuring range of motion for lower extremities
publisher Publishing Technology
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/21096/
http://umpir.ump.edu.my/id/eprint/21096/
http://umpir.ump.edu.my/id/eprint/21096/
http://umpir.ump.edu.my/id/eprint/21096/1/Development%20of%20the%20Wireless%20Goniometer%20in%20Measuring%20Range%20of%20Motion%20for%20Lower%20Extremities.pdf
first_indexed 2023-09-18T22:30:49Z
last_indexed 2023-09-18T22:30:49Z
_version_ 1777416273332797440