Analysis of grounding and harmonics in power quality issues

The purpose of this thesis is to present the importance and affects of grounding and harmonics to the quality of power. In this case, data center is referred as a case study for the analysis of grounding and harmonic. These power quality issues are very important in data center where it might cause...

Full description

Bibliographic Details
Main Author: Tan, Wannurzana Nyuk May
Format: Undergraduates Project Papers
Language:English
Published: 2010
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/2108/
http://umpir.ump.edu.my/id/eprint/2108/
http://umpir.ump.edu.my/id/eprint/2108/1/Wannurzana_Tan_Nyuk_May_%28_CD_5339_%29.pdf
id ump-2108
recordtype eprints
spelling ump-21082015-03-03T07:54:46Z http://umpir.ump.edu.my/id/eprint/2108/ Analysis of grounding and harmonics in power quality issues Tan, Wannurzana Nyuk May TK Electrical engineering. Electronics Nuclear engineering The purpose of this thesis is to present the importance and affects of grounding and harmonics to the quality of power. In this case, data center is referred as a case study for the analysis of grounding and harmonic. These power quality issues are very important in data center where it might cause severe failure operation systems. For the investigation of the quality of the power in data center, electrical disturbance log is done to examine the quality of grounding and characteristics of harmonics profiles in the data center. The power monitoring instrument used was Fluke 1750 Recorder and the data recorded was analyzed by using Fluke 1750 Analyze.. The power quality conditions of the data center significantly depends on the every aspect in electrical system such as voltage, current, frequency, power, power factor and so on. As the result of this analysis, the grounding conditions used in the data center was found to have no signs of severity in power quality conditions. However, there were some issues of improper wiring and grounding found in the data center. This will be discussed in this thesis. On the other hand, the harmonic distortion in data center were discussed in terms of the source of harmonics and effects of harmonic on the performance of data center. In order to identify the cause of such orders of harmonics in this system, the most non linear load is identified. Therefore, some recommendations and mitigations of the harmonics were discussed. 2010-12 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/2108/1/Wannurzana_Tan_Nyuk_May_%28_CD_5339_%29.pdf Tan, Wannurzana Nyuk May (2010) Analysis of grounding and harmonics in power quality issues. Faculty Of Electrical & Electronic Engineering, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:54926&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Tan, Wannurzana Nyuk May
Analysis of grounding and harmonics in power quality issues
description The purpose of this thesis is to present the importance and affects of grounding and harmonics to the quality of power. In this case, data center is referred as a case study for the analysis of grounding and harmonic. These power quality issues are very important in data center where it might cause severe failure operation systems. For the investigation of the quality of the power in data center, electrical disturbance log is done to examine the quality of grounding and characteristics of harmonics profiles in the data center. The power monitoring instrument used was Fluke 1750 Recorder and the data recorded was analyzed by using Fluke 1750 Analyze.. The power quality conditions of the data center significantly depends on the every aspect in electrical system such as voltage, current, frequency, power, power factor and so on. As the result of this analysis, the grounding conditions used in the data center was found to have no signs of severity in power quality conditions. However, there were some issues of improper wiring and grounding found in the data center. This will be discussed in this thesis. On the other hand, the harmonic distortion in data center were discussed in terms of the source of harmonics and effects of harmonic on the performance of data center. In order to identify the cause of such orders of harmonics in this system, the most non linear load is identified. Therefore, some recommendations and mitigations of the harmonics were discussed.
format Undergraduates Project Papers
author Tan, Wannurzana Nyuk May
author_facet Tan, Wannurzana Nyuk May
author_sort Tan, Wannurzana Nyuk May
title Analysis of grounding and harmonics in power quality issues
title_short Analysis of grounding and harmonics in power quality issues
title_full Analysis of grounding and harmonics in power quality issues
title_fullStr Analysis of grounding and harmonics in power quality issues
title_full_unstemmed Analysis of grounding and harmonics in power quality issues
title_sort analysis of grounding and harmonics in power quality issues
publishDate 2010
url http://umpir.ump.edu.my/id/eprint/2108/
http://umpir.ump.edu.my/id/eprint/2108/
http://umpir.ump.edu.my/id/eprint/2108/1/Wannurzana_Tan_Nyuk_May_%28_CD_5339_%29.pdf
first_indexed 2023-09-18T21:55:40Z
last_indexed 2023-09-18T21:55:40Z
_version_ 1777414061954170880