Effect of perforations on axially loaded I-section cold-formed steel column

Cold-formed steel structure are steel structural product that are made by bending flat sheets of steel at ambient temperature into shapes. The application of cold-formed steel is an extent to the Industrialized Building System (IBS) that promotes high quality of work with minimum waste. Cold-formed...

Full description

Bibliographic Details
Main Author: Nur Zayani, Zaharudin
Format: Undergraduates Project Papers
Language:English
English
English
English
Published: 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/20916/
http://umpir.ump.edu.my/id/eprint/20916/
http://umpir.ump.edu.my/id/eprint/20916/1/Effect%20of%20perforations%20on%20axially%20loaded%20I-section%20cold-formed%20steel%20column-Table%20of%20contents.pdf
http://umpir.ump.edu.my/id/eprint/20916/7/Effect%20of%20perforations%20on%20axially%20loaded%20I-section%20cold-formed%20steel%20column-Abstract.pdf
http://umpir.ump.edu.my/id/eprint/20916/13/Effect%20of%20perforations%20on%20axially%20loaded%20I-section%20cold-formed%20steel%20column-Chapter%201.pdf
http://umpir.ump.edu.my/id/eprint/20916/19/Effect%20of%20perforations%20on%20axially%20loaded%20I-section%20cold-formed%20steel%20column-References.pdf
id ump-20916
recordtype eprints
spelling ump-209162018-04-11T23:54:02Z http://umpir.ump.edu.my/id/eprint/20916/ Effect of perforations on axially loaded I-section cold-formed steel column Nur Zayani, Zaharudin TA Engineering (General). Civil engineering (General) Cold-formed steel structure are steel structural product that are made by bending flat sheets of steel at ambient temperature into shapes. The application of cold-formed steel is an extent to the Industrialized Building System (IBS) that promotes high quality of work with minimum waste. Cold-formed steel comes with various type of section based on their function and purpose in construction work. There are three main type of sections which are single open section, open built-up section and closed built-up section. This research will be concentrating on open built-up section or I-section. Structural members of cold-formed steel usually come with the presence of perforations. Perforations is a hole or opening that are made on the cold-formed steel to ease construction work. It usually provided with different shapes and size based on its function such as to accommodate electrical, plumbing and air conditioner or heating services. However, the presence of perforations may cause a reduction in strength of individual component elements and the overall strength of the member depending on the position, size and orientation of the opening. This research will focus on the effect of position and shape of the perforations on the structural strength of the axially loaded cold-formed steel column. An experimental investigation of cold-formed steel subjected to compression loading to study the effect of perforations on the load capacity of column members of built-up I-section is held. A total of 6 samples that have different position of perforations were tested in this experiment. Each member has nominal thickness of 1.6 mm, column length of 600 mm and were compressed between a simply supported end at both end. The result of this experiment shows that the ultimate load of each sample varies greatly on the perforation position. The result is presented in three section which are load vs vertical displacement, load vs horizontal displacement and buckling behavior. 2017-06 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/20916/1/Effect%20of%20perforations%20on%20axially%20loaded%20I-section%20cold-formed%20steel%20column-Table%20of%20contents.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/20916/7/Effect%20of%20perforations%20on%20axially%20loaded%20I-section%20cold-formed%20steel%20column-Abstract.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/20916/13/Effect%20of%20perforations%20on%20axially%20loaded%20I-section%20cold-formed%20steel%20column-Chapter%201.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/20916/19/Effect%20of%20perforations%20on%20axially%20loaded%20I-section%20cold-formed%20steel%20column-References.pdf Nur Zayani, Zaharudin (2017) Effect of perforations on axially loaded I-section cold-formed steel column. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:102646&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
English
English
English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Nur Zayani, Zaharudin
Effect of perforations on axially loaded I-section cold-formed steel column
description Cold-formed steel structure are steel structural product that are made by bending flat sheets of steel at ambient temperature into shapes. The application of cold-formed steel is an extent to the Industrialized Building System (IBS) that promotes high quality of work with minimum waste. Cold-formed steel comes with various type of section based on their function and purpose in construction work. There are three main type of sections which are single open section, open built-up section and closed built-up section. This research will be concentrating on open built-up section or I-section. Structural members of cold-formed steel usually come with the presence of perforations. Perforations is a hole or opening that are made on the cold-formed steel to ease construction work. It usually provided with different shapes and size based on its function such as to accommodate electrical, plumbing and air conditioner or heating services. However, the presence of perforations may cause a reduction in strength of individual component elements and the overall strength of the member depending on the position, size and orientation of the opening. This research will focus on the effect of position and shape of the perforations on the structural strength of the axially loaded cold-formed steel column. An experimental investigation of cold-formed steel subjected to compression loading to study the effect of perforations on the load capacity of column members of built-up I-section is held. A total of 6 samples that have different position of perforations were tested in this experiment. Each member has nominal thickness of 1.6 mm, column length of 600 mm and were compressed between a simply supported end at both end. The result of this experiment shows that the ultimate load of each sample varies greatly on the perforation position. The result is presented in three section which are load vs vertical displacement, load vs horizontal displacement and buckling behavior.
format Undergraduates Project Papers
author Nur Zayani, Zaharudin
author_facet Nur Zayani, Zaharudin
author_sort Nur Zayani, Zaharudin
title Effect of perforations on axially loaded I-section cold-formed steel column
title_short Effect of perforations on axially loaded I-section cold-formed steel column
title_full Effect of perforations on axially loaded I-section cold-formed steel column
title_fullStr Effect of perforations on axially loaded I-section cold-formed steel column
title_full_unstemmed Effect of perforations on axially loaded I-section cold-formed steel column
title_sort effect of perforations on axially loaded i-section cold-formed steel column
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/20916/
http://umpir.ump.edu.my/id/eprint/20916/
http://umpir.ump.edu.my/id/eprint/20916/1/Effect%20of%20perforations%20on%20axially%20loaded%20I-section%20cold-formed%20steel%20column-Table%20of%20contents.pdf
http://umpir.ump.edu.my/id/eprint/20916/7/Effect%20of%20perforations%20on%20axially%20loaded%20I-section%20cold-formed%20steel%20column-Abstract.pdf
http://umpir.ump.edu.my/id/eprint/20916/13/Effect%20of%20perforations%20on%20axially%20loaded%20I-section%20cold-formed%20steel%20column-Chapter%201.pdf
http://umpir.ump.edu.my/id/eprint/20916/19/Effect%20of%20perforations%20on%20axially%20loaded%20I-section%20cold-formed%20steel%20column-References.pdf
first_indexed 2023-09-18T22:30:27Z
last_indexed 2023-09-18T22:30:27Z
_version_ 1777416249951649792