Development of measuring temperature change for water quality index in UMP lake, Pekan Campus

This project proposed a development of temperature changing measuring system for water quality index in UMP Lake, Pekan Campus. Temperature is one of nine critical water qualities and environmental parameter because it governs the kinds and types of aquatic life, regulates the maximum dissolved oxyg...

Full description

Bibliographic Details
Main Author: Muhammad Zaifulfazli, Zailani
Format: Undergraduates Project Papers
Language:English
Published: 2010
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/2001/
http://umpir.ump.edu.my/id/eprint/2001/1/Muhammad_Zaifulfazli_Zailani_%28_CD_5409_%29.pdf
id ump-2001
recordtype eprints
spelling ump-20012015-03-03T07:54:02Z http://umpir.ump.edu.my/id/eprint/2001/ Development of measuring temperature change for water quality index in UMP lake, Pekan Campus Muhammad Zaifulfazli, Zailani TK Electrical engineering. Electronics Nuclear engineering This project proposed a development of temperature changing measuring system for water quality index in UMP Lake, Pekan Campus. Temperature is one of nine critical water qualities and environmental parameter because it governs the kinds and types of aquatic life, regulates the maximum dissolved oxygen. With respect to chemical and biological reactions, when the water temperature is increased, the rate of chemical and metabolic reactions will also increase. This project will use Graphic User Interface (GUI) of Visual Basic, the software will be the data storage which save all the data measured by the temperature sensor. The temperature sensor will send a feedback through ZigBee Compatible Wireless device. The current technology in adopting wireless terminal technology for instrumentation directly leads to efficient process. In a warm water streams, the temperatures should not exceed 89 degrees Fahrenheit. Cold water streams should not exceed 68 degrees Fahrenheit. The expected result is the sensor will monitor the temperature in UMP Lake and send the data to the software. If the sensor detect the water temperatures exceed 89 degrees Fahrenheit, or 68 degrees Fahrenheit in cold water stream, it will send a warning signal to the computer through the wireless device. 2010-12 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/2001/1/Muhammad_Zaifulfazli_Zailani_%28_CD_5409_%29.pdf Muhammad Zaifulfazli, Zailani (2010) Development of measuring temperature change for water quality index in UMP lake, Pekan Campus. Faculty Of Electrical & Electronic Engineering, Universiti Malaysia Pahang.
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Muhammad Zaifulfazli, Zailani
Development of measuring temperature change for water quality index in UMP lake, Pekan Campus
description This project proposed a development of temperature changing measuring system for water quality index in UMP Lake, Pekan Campus. Temperature is one of nine critical water qualities and environmental parameter because it governs the kinds and types of aquatic life, regulates the maximum dissolved oxygen. With respect to chemical and biological reactions, when the water temperature is increased, the rate of chemical and metabolic reactions will also increase. This project will use Graphic User Interface (GUI) of Visual Basic, the software will be the data storage which save all the data measured by the temperature sensor. The temperature sensor will send a feedback through ZigBee Compatible Wireless device. The current technology in adopting wireless terminal technology for instrumentation directly leads to efficient process. In a warm water streams, the temperatures should not exceed 89 degrees Fahrenheit. Cold water streams should not exceed 68 degrees Fahrenheit. The expected result is the sensor will monitor the temperature in UMP Lake and send the data to the software. If the sensor detect the water temperatures exceed 89 degrees Fahrenheit, or 68 degrees Fahrenheit in cold water stream, it will send a warning signal to the computer through the wireless device.
format Undergraduates Project Papers
author Muhammad Zaifulfazli, Zailani
author_facet Muhammad Zaifulfazli, Zailani
author_sort Muhammad Zaifulfazli, Zailani
title Development of measuring temperature change for water quality index in UMP lake, Pekan Campus
title_short Development of measuring temperature change for water quality index in UMP lake, Pekan Campus
title_full Development of measuring temperature change for water quality index in UMP lake, Pekan Campus
title_fullStr Development of measuring temperature change for water quality index in UMP lake, Pekan Campus
title_full_unstemmed Development of measuring temperature change for water quality index in UMP lake, Pekan Campus
title_sort development of measuring temperature change for water quality index in ump lake, pekan campus
publishDate 2010
url http://umpir.ump.edu.my/id/eprint/2001/
http://umpir.ump.edu.my/id/eprint/2001/1/Muhammad_Zaifulfazli_Zailani_%28_CD_5409_%29.pdf
first_indexed 2023-09-18T21:55:27Z
last_indexed 2023-09-18T21:55:27Z
_version_ 1777414047828803584