Static and dynamic impacts of shunt capacitor placement in distribution systems

Adding capacitors to power system distributions provides well known benefits, including power factor correction, voltage support and increase of active power transfer capacity. This thesis will presents the static and dynamic impacts of shunt capacitor placement in distribution systems by describes...

Full description

Bibliographic Details
Main Author: Rafidah, Abdul Kadir
Format: Undergraduates Project Papers
Language:English
Published: 2009
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/1948/
http://umpir.ump.edu.my/id/eprint/1948/1/Rafidah_Abdul_Kadir_%28_CD_5360_%29.pdf
id ump-1948
recordtype eprints
spelling ump-19482015-03-03T07:53:45Z http://umpir.ump.edu.my/id/eprint/1948/ Static and dynamic impacts of shunt capacitor placement in distribution systems Rafidah, Abdul Kadir TK Electrical engineering. Electronics Nuclear engineering Adding capacitors to power system distributions provides well known benefits, including power factor correction, voltage support and increase of active power transfer capacity. This thesis will presents the static and dynamic impacts of shunt capacitor placement in distribution systems by describes measurements and studies performed before and after the installation of 49.46MVAr capacitor banks in 4-bus test system and a 37.92MVar capacitor banks in-9 bus test systems. A load flow analysis is conducted to predict power flow magnitudes, power factor, voltage levels and losses in branches of the system. The results are used to determine the size of capacitor banks to maintain an acceptable power factor and or voltage level to measure the power losses before and after capacitor bank installation. The fault analysis also been studied by applying single line to ground fault to see the impacts when fault applied before and after installation of capacitor bank since most of researcher did not include the capacitors in fault studies. Switching transients analysis were also studied since the capacitor switching transient can be very damaging and costly problems where the transient voltage on the power system causes the power and voltage flows in the system to change from the steady-state value. Thus in order to take appropriate pre-cautions in real system, it is necessary and advantageous to analyze and determine the worst case switching transients before the actual switching take place. In this thesis, 2 test systems which were developed for power flow analysis was used to examine characteristics of transient voltage by using 3 set of different size of capacitor bank. The basic fundamental method to reduce the transient voltage also been investigated. The results of measurements are compared to the ones obtained by studies and simulations. The modeling and transient simulation were carried out by using MATLAB and PSCAD software. 2009-12 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/1948/1/Rafidah_Abdul_Kadir_%28_CD_5360_%29.pdf Rafidah, Abdul Kadir (2009) Static and dynamic impacts of shunt capacitor placement in distribution systems. Faculty Of Electrical & Electronic Engineering, Universiti Malaysia Pahang.
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Rafidah, Abdul Kadir
Static and dynamic impacts of shunt capacitor placement in distribution systems
description Adding capacitors to power system distributions provides well known benefits, including power factor correction, voltage support and increase of active power transfer capacity. This thesis will presents the static and dynamic impacts of shunt capacitor placement in distribution systems by describes measurements and studies performed before and after the installation of 49.46MVAr capacitor banks in 4-bus test system and a 37.92MVar capacitor banks in-9 bus test systems. A load flow analysis is conducted to predict power flow magnitudes, power factor, voltage levels and losses in branches of the system. The results are used to determine the size of capacitor banks to maintain an acceptable power factor and or voltage level to measure the power losses before and after capacitor bank installation. The fault analysis also been studied by applying single line to ground fault to see the impacts when fault applied before and after installation of capacitor bank since most of researcher did not include the capacitors in fault studies. Switching transients analysis were also studied since the capacitor switching transient can be very damaging and costly problems where the transient voltage on the power system causes the power and voltage flows in the system to change from the steady-state value. Thus in order to take appropriate pre-cautions in real system, it is necessary and advantageous to analyze and determine the worst case switching transients before the actual switching take place. In this thesis, 2 test systems which were developed for power flow analysis was used to examine characteristics of transient voltage by using 3 set of different size of capacitor bank. The basic fundamental method to reduce the transient voltage also been investigated. The results of measurements are compared to the ones obtained by studies and simulations. The modeling and transient simulation were carried out by using MATLAB and PSCAD software.
format Undergraduates Project Papers
author Rafidah, Abdul Kadir
author_facet Rafidah, Abdul Kadir
author_sort Rafidah, Abdul Kadir
title Static and dynamic impacts of shunt capacitor placement in distribution systems
title_short Static and dynamic impacts of shunt capacitor placement in distribution systems
title_full Static and dynamic impacts of shunt capacitor placement in distribution systems
title_fullStr Static and dynamic impacts of shunt capacitor placement in distribution systems
title_full_unstemmed Static and dynamic impacts of shunt capacitor placement in distribution systems
title_sort static and dynamic impacts of shunt capacitor placement in distribution systems
publishDate 2009
url http://umpir.ump.edu.my/id/eprint/1948/
http://umpir.ump.edu.my/id/eprint/1948/1/Rafidah_Abdul_Kadir_%28_CD_5360_%29.pdf
first_indexed 2023-09-18T21:55:19Z
last_indexed 2023-09-18T21:55:19Z
_version_ 1777414040229773312