Development of auto re-closer earth leakage circuit breaker for domestic appliances

System protection is the important requirement in electrical power system. The using of protection system can avoid and prevent system from damaged. Electrical energy has caused dangers to human life and machine. Earth leakage circuit breaker (ELCB) is one from protection device that introduced to p...

Full description

Bibliographic Details
Main Author: Muhammad Syafi'i, Ali
Format: Undergraduates Project Papers
Language:English
Published: 2009
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/1942/
http://umpir.ump.edu.my/id/eprint/1942/
http://umpir.ump.edu.my/id/eprint/1942/1/Muhammad_Syafi%27i_Ali_%28_CD_5369_%29pdf.pdf
id ump-1942
recordtype eprints
spelling ump-19422015-03-03T07:53:43Z http://umpir.ump.edu.my/id/eprint/1942/ Development of auto re-closer earth leakage circuit breaker for domestic appliances Muhammad Syafi'i, Ali TK Electrical engineering. Electronics Nuclear engineering System protection is the important requirement in electrical power system. The using of protection system can avoid and prevent system from damaged. Electrical energy has caused dangers to human life and machine. Earth leakage circuit breaker (ELCB) is one from protection device that introduced to protect the system. This device is the brain of protection system that monitors input current from power line by it sensor Zero Current Transformer (ZCT), then sending the tripping signal to mechanical switch to disconnected system. ELCB is widely applied by consumer weather is for resident, factory, laboratory and also in power distribution. Because industrial operation requires protection of their Equipment from the lightning, short-circuit and also over-current, so the ELCB will serve the purpose as the protection of their system. This project will focused to improve the ability of current ELCB so that it have ability in identify fault, act accordingly, display the fault(permanent fault and temporary fault) and also re-close it back to normal condition.PIC will execute their instruction when different current from both of current transducer is exceed pre-determine value of sensitivity, 100mA. In this project PIC microcontroller will control and operate solid state relay which replacing the application of current mechanical switch. 2009-12 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/1942/1/Muhammad_Syafi%27i_Ali_%28_CD_5369_%29pdf.pdf Muhammad Syafi'i, Ali (2009) Development of auto re-closer earth leakage circuit breaker for domestic appliances. Faculty of Electrical & Electronic Engineering, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:55168&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Muhammad Syafi'i, Ali
Development of auto re-closer earth leakage circuit breaker for domestic appliances
description System protection is the important requirement in electrical power system. The using of protection system can avoid and prevent system from damaged. Electrical energy has caused dangers to human life and machine. Earth leakage circuit breaker (ELCB) is one from protection device that introduced to protect the system. This device is the brain of protection system that monitors input current from power line by it sensor Zero Current Transformer (ZCT), then sending the tripping signal to mechanical switch to disconnected system. ELCB is widely applied by consumer weather is for resident, factory, laboratory and also in power distribution. Because industrial operation requires protection of their Equipment from the lightning, short-circuit and also over-current, so the ELCB will serve the purpose as the protection of their system. This project will focused to improve the ability of current ELCB so that it have ability in identify fault, act accordingly, display the fault(permanent fault and temporary fault) and also re-close it back to normal condition.PIC will execute their instruction when different current from both of current transducer is exceed pre-determine value of sensitivity, 100mA. In this project PIC microcontroller will control and operate solid state relay which replacing the application of current mechanical switch.
format Undergraduates Project Papers
author Muhammad Syafi'i, Ali
author_facet Muhammad Syafi'i, Ali
author_sort Muhammad Syafi'i, Ali
title Development of auto re-closer earth leakage circuit breaker for domestic appliances
title_short Development of auto re-closer earth leakage circuit breaker for domestic appliances
title_full Development of auto re-closer earth leakage circuit breaker for domestic appliances
title_fullStr Development of auto re-closer earth leakage circuit breaker for domestic appliances
title_full_unstemmed Development of auto re-closer earth leakage circuit breaker for domestic appliances
title_sort development of auto re-closer earth leakage circuit breaker for domestic appliances
publishDate 2009
url http://umpir.ump.edu.my/id/eprint/1942/
http://umpir.ump.edu.my/id/eprint/1942/
http://umpir.ump.edu.my/id/eprint/1942/1/Muhammad_Syafi%27i_Ali_%28_CD_5369_%29pdf.pdf
first_indexed 2023-09-18T21:55:18Z
last_indexed 2023-09-18T21:55:18Z
_version_ 1777414039352115200