Building energy analysis using cooling load factor/cooling load temperature different (CLF/CLTD)

This project is carried out to indentify whether the existing cooling capacity is suffice for an occupied building. The first objective of this project is to determine the heat gain of FKM Administration Building when it’s fully occupied. The second objective of this project is to compare the calcul...

Full description

Bibliographic Details
Main Author: Mohd Firdaus, Musa
Format: Undergraduates Project Papers
Language:English
English
English
English
English
Published: 2010
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/1862/
http://umpir.ump.edu.my/id/eprint/1862/
http://umpir.ump.edu.my/id/eprint/1862/1/Mohd_Firdaus_Musa_%28_CD_4956_%29.pdf
http://umpir.ump.edu.my/id/eprint/1862/4/Building%20energy%20analysis%20using%20cooling%20load%20factorcooling%20load%20temperature%20different%20%28CLFCLTD%29%20-%20Chapter%201.pdf
http://umpir.ump.edu.my/id/eprint/1862/5/Building%20energy%20analysis%20using%20cooling%20load%20factorcooling%20load%20temperature%20different%20%28CLFCLTD%29%20-%20References.pdf
http://umpir.ump.edu.my/id/eprint/1862/6/Building%20energy%20analysis%20using%20cooling%20load%20factorcooling%20load%20temperature%20different%20%28CLFCLTD%29%20-%20Abstract.pdf
http://umpir.ump.edu.my/id/eprint/1862/27/Building%20energy%20analysis%20using%20cooling%20load%20factorcooling%20load%20temperature%20different%20%28CLFCLTD%29%20-%20Table%20of%20content.pdf
id ump-1862
recordtype eprints
spelling ump-18622017-03-09T01:44:47Z http://umpir.ump.edu.my/id/eprint/1862/ Building energy analysis using cooling load factor/cooling load temperature different (CLF/CLTD) Mohd Firdaus, Musa TJ Mechanical engineering and machinery This project is carried out to indentify whether the existing cooling capacity is suffice for an occupied building. The first objective of this project is to determine the heat gain of FKM Administration Building when it’s fully occupied. The second objective of this project is to compare the calculated heat gain against the existing cooling capacity. FKM Administration Building was chosen as the case study. The architectural drawing of FKM Administration Building is first studied to review the building specifications. The building specification is used in the calculation of heat gain in order to identify the cooling load required for FKM Administration Building. When FKM Administration Building is fully occupied, the number of occupant will be around 396 peoples. The type of air-conditioning system used in FKM Administration Building is central air conditioning system and the total existing cooling load is observed to be 381.8 kW. The peak heat gain is calculated as 492.7 kW using Cooling Load Factor/ Cooling Load Temperature Difference (CLF/CLTD) method at 4 pm. Therefore, the existing cooling load is observed to be undersized in design. However, the peak heat gain will only happen occasionally throughout the year. In order to overcome the undersized design cooling capacity problem, the cooling capacity should increase 29%. 2010-12 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/1862/1/Mohd_Firdaus_Musa_%28_CD_4956_%29.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/1862/4/Building%20energy%20analysis%20using%20cooling%20load%20factorcooling%20load%20temperature%20different%20%28CLFCLTD%29%20-%20Chapter%201.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/1862/5/Building%20energy%20analysis%20using%20cooling%20load%20factorcooling%20load%20temperature%20different%20%28CLFCLTD%29%20-%20References.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/1862/6/Building%20energy%20analysis%20using%20cooling%20load%20factorcooling%20load%20temperature%20different%20%28CLFCLTD%29%20-%20Abstract.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/1862/27/Building%20energy%20analysis%20using%20cooling%20load%20factorcooling%20load%20temperature%20different%20%28CLFCLTD%29%20-%20Table%20of%20content.pdf Mohd Firdaus, Musa (2010) Building energy analysis using cooling load factor/cooling load temperature different (CLF/CLTD). Faculty of Mechanical Engineering, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:52281&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
English
English
English
English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Mohd Firdaus, Musa
Building energy analysis using cooling load factor/cooling load temperature different (CLF/CLTD)
description This project is carried out to indentify whether the existing cooling capacity is suffice for an occupied building. The first objective of this project is to determine the heat gain of FKM Administration Building when it’s fully occupied. The second objective of this project is to compare the calculated heat gain against the existing cooling capacity. FKM Administration Building was chosen as the case study. The architectural drawing of FKM Administration Building is first studied to review the building specifications. The building specification is used in the calculation of heat gain in order to identify the cooling load required for FKM Administration Building. When FKM Administration Building is fully occupied, the number of occupant will be around 396 peoples. The type of air-conditioning system used in FKM Administration Building is central air conditioning system and the total existing cooling load is observed to be 381.8 kW. The peak heat gain is calculated as 492.7 kW using Cooling Load Factor/ Cooling Load Temperature Difference (CLF/CLTD) method at 4 pm. Therefore, the existing cooling load is observed to be undersized in design. However, the peak heat gain will only happen occasionally throughout the year. In order to overcome the undersized design cooling capacity problem, the cooling capacity should increase 29%.
format Undergraduates Project Papers
author Mohd Firdaus, Musa
author_facet Mohd Firdaus, Musa
author_sort Mohd Firdaus, Musa
title Building energy analysis using cooling load factor/cooling load temperature different (CLF/CLTD)
title_short Building energy analysis using cooling load factor/cooling load temperature different (CLF/CLTD)
title_full Building energy analysis using cooling load factor/cooling load temperature different (CLF/CLTD)
title_fullStr Building energy analysis using cooling load factor/cooling load temperature different (CLF/CLTD)
title_full_unstemmed Building energy analysis using cooling load factor/cooling load temperature different (CLF/CLTD)
title_sort building energy analysis using cooling load factor/cooling load temperature different (clf/cltd)
publishDate 2010
url http://umpir.ump.edu.my/id/eprint/1862/
http://umpir.ump.edu.my/id/eprint/1862/
http://umpir.ump.edu.my/id/eprint/1862/1/Mohd_Firdaus_Musa_%28_CD_4956_%29.pdf
http://umpir.ump.edu.my/id/eprint/1862/4/Building%20energy%20analysis%20using%20cooling%20load%20factorcooling%20load%20temperature%20different%20%28CLFCLTD%29%20-%20Chapter%201.pdf
http://umpir.ump.edu.my/id/eprint/1862/5/Building%20energy%20analysis%20using%20cooling%20load%20factorcooling%20load%20temperature%20different%20%28CLFCLTD%29%20-%20References.pdf
http://umpir.ump.edu.my/id/eprint/1862/6/Building%20energy%20analysis%20using%20cooling%20load%20factorcooling%20load%20temperature%20different%20%28CLFCLTD%29%20-%20Abstract.pdf
http://umpir.ump.edu.my/id/eprint/1862/27/Building%20energy%20analysis%20using%20cooling%20load%20factorcooling%20load%20temperature%20different%20%28CLFCLTD%29%20-%20Table%20of%20content.pdf
first_indexed 2023-09-18T21:55:08Z
last_indexed 2023-09-18T21:55:08Z
_version_ 1777414028626231296