Effects of Operation Conditions on Performance of a Gas Turbine Power Plant

This paper presents the effect of operation conditions (compression ratio, turbine inlet temperature, air to fuel ratio and efficiency of compressor and turbine) on the performance of gas turbine power plant. The computational model was developed utilizing the MATLAB codes. Turbine work found to be...

Full description

Bibliographic Details
Main Authors: M. M., Rahman, Thamir K., Ibrahim
Format: Conference or Workshop Item
Language:English
Published: 2010
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/1776/
http://umpir.ump.edu.my/id/eprint/1776/1/EFFECTS_OF_OPERATION_CONDITIONS_ON_PERFORMANCE_OF_A_GAS.pdf
id ump-1776
recordtype eprints
spelling ump-17762018-01-25T07:21:32Z http://umpir.ump.edu.my/id/eprint/1776/ Effects of Operation Conditions on Performance of a Gas Turbine Power Plant M. M., Rahman Thamir K., Ibrahim TJ Mechanical engineering and machinery This paper presents the effect of operation conditions (compression ratio, turbine inlet temperature, air to fuel ratio and efficiency of compressor and turbine) on the performance of gas turbine power plant. The computational model was developed utilizing the MATLAB codes. Turbine work found to be decreases as ambient temperature increases as well as the thermal efficiency decreases. It can be seen that the thermal efficiency increases linearly with increases of compression ratio while decreases of ambient temperature. The specific fuel consumption increases with increases of ambient temperature and lower turbine inlet temperature. The effect of variation of SFC is more significance at higher ambient temperature than lower temperature. It is observed that the thermal efficiency linearly increases at lower compressor ratio as well as higher turbine inlet temperature until certain value of compression ratio. The variation of thermal efficiency is more significance at higher compression ratio and lower turbine inlet temperature. Even though at lower turbine inlet temperature is decrement the thermal efficiency dramatically and the SFC decreases linearly with increases of compression ratio and turbine inlet temperature at lower range until certain value then increases dramatically for lower turbine inlet temperature. 2010 Conference or Workshop Item PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/1776/1/EFFECTS_OF_OPERATION_CONDITIONS_ON_PERFORMANCE_OF_A_GAS.pdf M. M., Rahman and Thamir K., Ibrahim (2010) Effects of Operation Conditions on Performance of a Gas Turbine Power Plant. In: National Conference in Mechanical Engineering Research and Postgraduate Studies (2nd NCMER 2010), 3-4 December 2010 , UMP Pekan, Pahang. .
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
M. M., Rahman
Thamir K., Ibrahim
Effects of Operation Conditions on Performance of a Gas Turbine Power Plant
description This paper presents the effect of operation conditions (compression ratio, turbine inlet temperature, air to fuel ratio and efficiency of compressor and turbine) on the performance of gas turbine power plant. The computational model was developed utilizing the MATLAB codes. Turbine work found to be decreases as ambient temperature increases as well as the thermal efficiency decreases. It can be seen that the thermal efficiency increases linearly with increases of compression ratio while decreases of ambient temperature. The specific fuel consumption increases with increases of ambient temperature and lower turbine inlet temperature. The effect of variation of SFC is more significance at higher ambient temperature than lower temperature. It is observed that the thermal efficiency linearly increases at lower compressor ratio as well as higher turbine inlet temperature until certain value of compression ratio. The variation of thermal efficiency is more significance at higher compression ratio and lower turbine inlet temperature. Even though at lower turbine inlet temperature is decrement the thermal efficiency dramatically and the SFC decreases linearly with increases of compression ratio and turbine inlet temperature at lower range until certain value then increases dramatically for lower turbine inlet temperature.
format Conference or Workshop Item
author M. M., Rahman
Thamir K., Ibrahim
author_facet M. M., Rahman
Thamir K., Ibrahim
author_sort M. M., Rahman
title Effects of Operation Conditions on Performance of a Gas Turbine Power Plant
title_short Effects of Operation Conditions on Performance of a Gas Turbine Power Plant
title_full Effects of Operation Conditions on Performance of a Gas Turbine Power Plant
title_fullStr Effects of Operation Conditions on Performance of a Gas Turbine Power Plant
title_full_unstemmed Effects of Operation Conditions on Performance of a Gas Turbine Power Plant
title_sort effects of operation conditions on performance of a gas turbine power plant
publishDate 2010
url http://umpir.ump.edu.my/id/eprint/1776/
http://umpir.ump.edu.my/id/eprint/1776/1/EFFECTS_OF_OPERATION_CONDITIONS_ON_PERFORMANCE_OF_A_GAS.pdf
first_indexed 2023-09-18T21:55:00Z
last_indexed 2023-09-18T21:55:00Z
_version_ 1777414020474601472