Experimental determination of convective heat transfer coefficient in wire electro discharge machining

Wire electro discharge machining (WEDM) is a fully extended and competitive machining process widely used to produce dies and moulds. However, the risk of wire breakage affects adversely the full potential of WEDM since the overall process efficiency is considerably reduced. These symptoms are espec...

Full description

Bibliographic Details
Main Author: Nadiah Waznah, Zabidi
Format: Undergraduates Project Papers
Language:English
Published: 2008
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/155/
http://umpir.ump.edu.my/id/eprint/155/
http://umpir.ump.edu.my/id/eprint/155/1/5_Nadiah_Waznah_Zabidi.pdf
id ump-155
recordtype eprints
spelling ump-1552015-03-03T06:15:36Z http://umpir.ump.edu.my/id/eprint/155/ Experimental determination of convective heat transfer coefficient in wire electro discharge machining Nadiah Waznah, Zabidi TJ Mechanical engineering and machinery Wire electro discharge machining (WEDM) is a fully extended and competitive machining process widely used to produce dies and moulds. However, the risk of wire breakage affects adversely the full potential of WEDM since the overall process efficiency is considerably reduced. These symptoms are especially related to the occurrence of an increase in discharge energy, peak current, as well as increases or decreases in ignition delay time. Because of that, an experimental determination method of the convective heat transfer coefficient in wire electro discharge machining is introduced to prevent the wire breaks during running the machine. Parameters such as peak current and flushing pressure are studied. A special device is developed to measure the average temperature increment of the wire after a period of short circuit discharges, and the thermal load imposed on the wire is also tracked and recorded in advance. Then, based on the thermal model of the wire, the convective coefficient can be calculated accurately. Some tuning experiments are carried out inside and outside a previously cut profile to examine the influence of the kerf on the convective coefficient. With this method, the effect of the coolant flushing pressure on the convective coefficient can be estimated. Based on the results of the analyses, this paper contributes to improve the process performance through a wire breakage. 2008-11 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/155/1/5_Nadiah_Waznah_Zabidi.pdf Nadiah Waznah, Zabidi (2008) Experimental determination of convective heat transfer coefficient in wire electro discharge machining. Faculty of Mechanical Engineering, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:41106&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Nadiah Waznah, Zabidi
Experimental determination of convective heat transfer coefficient in wire electro discharge machining
description Wire electro discharge machining (WEDM) is a fully extended and competitive machining process widely used to produce dies and moulds. However, the risk of wire breakage affects adversely the full potential of WEDM since the overall process efficiency is considerably reduced. These symptoms are especially related to the occurrence of an increase in discharge energy, peak current, as well as increases or decreases in ignition delay time. Because of that, an experimental determination method of the convective heat transfer coefficient in wire electro discharge machining is introduced to prevent the wire breaks during running the machine. Parameters such as peak current and flushing pressure are studied. A special device is developed to measure the average temperature increment of the wire after a period of short circuit discharges, and the thermal load imposed on the wire is also tracked and recorded in advance. Then, based on the thermal model of the wire, the convective coefficient can be calculated accurately. Some tuning experiments are carried out inside and outside a previously cut profile to examine the influence of the kerf on the convective coefficient. With this method, the effect of the coolant flushing pressure on the convective coefficient can be estimated. Based on the results of the analyses, this paper contributes to improve the process performance through a wire breakage.
format Undergraduates Project Papers
author Nadiah Waznah, Zabidi
author_facet Nadiah Waznah, Zabidi
author_sort Nadiah Waznah, Zabidi
title Experimental determination of convective heat transfer coefficient in wire electro discharge machining
title_short Experimental determination of convective heat transfer coefficient in wire electro discharge machining
title_full Experimental determination of convective heat transfer coefficient in wire electro discharge machining
title_fullStr Experimental determination of convective heat transfer coefficient in wire electro discharge machining
title_full_unstemmed Experimental determination of convective heat transfer coefficient in wire electro discharge machining
title_sort experimental determination of convective heat transfer coefficient in wire electro discharge machining
publishDate 2008
url http://umpir.ump.edu.my/id/eprint/155/
http://umpir.ump.edu.my/id/eprint/155/
http://umpir.ump.edu.my/id/eprint/155/1/5_Nadiah_Waznah_Zabidi.pdf
first_indexed 2023-09-18T21:52:02Z
last_indexed 2023-09-18T21:52:02Z
_version_ 1777413832909520896