The Influenced of Localized Corrosion on the Natural Frequency in the Reinforced Concrete Beam

This study presents the use of natural frequency for the identification of damage location in detecting the location and severity of corrosion in reinforced concrete beam models. The simply supported beam was modeled with five different corrosion factors, f using DIANA Release 9.1 software. The simu...

Full description

Bibliographic Details
Main Authors: Noorli, Ismail, Hanita, Yusof, Mohd Faizal, Md Jaafar
Format: Book Section
Language:English
Published: Springer 2016
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/14548/
http://umpir.ump.edu.my/id/eprint/14548/
http://umpir.ump.edu.my/id/eprint/14548/
http://umpir.ump.edu.my/id/eprint/14548/1/The%20Influenced%20of%20Localized%20Corrosion%20on%20the%20Natural%20Frequency%20in%20the%20Reinforced%20Concrete%20Beam.pdf
id ump-14548
recordtype eprints
spelling ump-145482018-05-03T07:04:12Z http://umpir.ump.edu.my/id/eprint/14548/ The Influenced of Localized Corrosion on the Natural Frequency in the Reinforced Concrete Beam Noorli, Ismail Hanita, Yusof Mohd Faizal, Md Jaafar TA Engineering (General). Civil engineering (General) This study presents the use of natural frequency for the identification of damage location in detecting the location and severity of corrosion in reinforced concrete beam models. The simply supported beam was modeled with five different corrosion factors, f using DIANA Release 9.1 software. The simulation models was applied in uncorroded beam (Beam UC) and corroded beam with corrosion factor of 8 % (Beam LD8), 16 % (Beam LD16), 32 % (Beam LD32), and 64 % (Beam LD64). The total span of 2200 mm with 20 locations in the steel bar was analyzed for localized corrosion including the distance near to supports. The technique was necessitated with the performance of linear, nonlinear, and eigenvalue analysis. The ratio of frequency drop of f corrode/uncorrode was obtained to visualize all modes at the corroded location. The results of frequency drop illustrated that the poorest location of corrosion was detected at x/L between 0.4 and 0.7. It can be concluded, the ratio of f corrode/uncorrode can be used to damage indicator to detect the localized corrosion. Springer 2016 Book Section PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/14548/1/The%20Influenced%20of%20Localized%20Corrosion%20on%20the%20Natural%20Frequency%20in%20the%20Reinforced%20Concrete%20Beam.pdf Noorli, Ismail and Hanita, Yusof and Mohd Faizal, Md Jaafar (2016) The Influenced of Localized Corrosion on the Natural Frequency in the Reinforced Concrete Beam. In: InCIEC 2015: Proceedings of the International Civil and Infrastructure Engineering Conference. Springer, Singapore, pp. 117-124. ISBN 978-981-10-0154-3 http://link.springer.com/chapter/10.1007/978-981-10-0155-0_12 DOI: 10.1007/978-981-10-0155-0_12
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Noorli, Ismail
Hanita, Yusof
Mohd Faizal, Md Jaafar
The Influenced of Localized Corrosion on the Natural Frequency in the Reinforced Concrete Beam
description This study presents the use of natural frequency for the identification of damage location in detecting the location and severity of corrosion in reinforced concrete beam models. The simply supported beam was modeled with five different corrosion factors, f using DIANA Release 9.1 software. The simulation models was applied in uncorroded beam (Beam UC) and corroded beam with corrosion factor of 8 % (Beam LD8), 16 % (Beam LD16), 32 % (Beam LD32), and 64 % (Beam LD64). The total span of 2200 mm with 20 locations in the steel bar was analyzed for localized corrosion including the distance near to supports. The technique was necessitated with the performance of linear, nonlinear, and eigenvalue analysis. The ratio of frequency drop of f corrode/uncorrode was obtained to visualize all modes at the corroded location. The results of frequency drop illustrated that the poorest location of corrosion was detected at x/L between 0.4 and 0.7. It can be concluded, the ratio of f corrode/uncorrode can be used to damage indicator to detect the localized corrosion.
format Book Section
author Noorli, Ismail
Hanita, Yusof
Mohd Faizal, Md Jaafar
author_facet Noorli, Ismail
Hanita, Yusof
Mohd Faizal, Md Jaafar
author_sort Noorli, Ismail
title The Influenced of Localized Corrosion on the Natural Frequency in the Reinforced Concrete Beam
title_short The Influenced of Localized Corrosion on the Natural Frequency in the Reinforced Concrete Beam
title_full The Influenced of Localized Corrosion on the Natural Frequency in the Reinforced Concrete Beam
title_fullStr The Influenced of Localized Corrosion on the Natural Frequency in the Reinforced Concrete Beam
title_full_unstemmed The Influenced of Localized Corrosion on the Natural Frequency in the Reinforced Concrete Beam
title_sort influenced of localized corrosion on the natural frequency in the reinforced concrete beam
publisher Springer
publishDate 2016
url http://umpir.ump.edu.my/id/eprint/14548/
http://umpir.ump.edu.my/id/eprint/14548/
http://umpir.ump.edu.my/id/eprint/14548/
http://umpir.ump.edu.my/id/eprint/14548/1/The%20Influenced%20of%20Localized%20Corrosion%20on%20the%20Natural%20Frequency%20in%20the%20Reinforced%20Concrete%20Beam.pdf
first_indexed 2023-09-18T22:18:25Z
last_indexed 2023-09-18T22:18:25Z
_version_ 1777415493668306944