Bending Behavior of Semi-Continuous Prefabricated Profiled Steel Sheeting (PSSDB) Floor Panels
Profiled Steel Sheeting Dry Board (PSSDB) floor panel is a composite of dry board and profiled steel sheeting screwed together by means of self-tapping, self-drilling shear connectors. The system has been successfully implemented in many Malaysian construction projects. Recently, the PSSDB system ha...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UMP
2011
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/14472/ http://umpir.ump.edu.my/id/eprint/14472/ http://umpir.ump.edu.my/id/eprint/14472/1/Bending%20Behavior%20of%20Semi-Continuous%20Prefabricated%20Profiled%20Steel.pdf |
id |
ump-14472 |
---|---|
recordtype |
eprints |
spelling |
ump-144722018-02-07T06:46:24Z http://umpir.ump.edu.my/id/eprint/14472/ Bending Behavior of Semi-Continuous Prefabricated Profiled Steel Sheeting (PSSDB) Floor Panels Norhaiza, Nordin Wan Hamidon, Wan Badaruzzaman Nasly, Mohamed Ali Wan Mansor, Wan Muhamad Khairunisa, Muthusamy TA Engineering (General). Civil engineering (General) Profiled Steel Sheeting Dry Board (PSSDB) floor panel is a composite of dry board and profiled steel sheeting screwed together by means of self-tapping, self-drilling shear connectors. The system has been successfully implemented in many Malaysian construction projects. Recently, the PSSDB system has been expanded to be an easy to assemble prefabricated floor for rural school cabin construction. An innovative prefabricated panel consists of three PSSDB parts which are then screwed together on site to form a semicontinuous panel has been proposed. This paper describes the three distinct parts of the panel, their assembly and the experiment to study the bending behavior of the panel. The semi-continuous panel performance was also compared to that of a continuous panel. All together, six 3.0 m span samples were tested under a uniformly distributed load until failure. The semi-continuous panels showed a two-phase behavior whilst the continuous panels showed a threephase behavior under loading which were related to the time of cracking of the dry board and the buckling of the profiled steel sheeting. The mid span deflections were recorded and used to determine the stiffness of the panels. Results showed that the stiffness of the semi-continuous panels were half of that of the continuous panels. It can be concluded that the discontinued spanning of the profiled steel sheeting has severely reduced the overall semicontinuous panel stiffness. The 25 screws used in the 0.6 m middle connecting panel had shown to be quite insufficient to hold the whole semi continuous panel together. Therefore, the addition of screws with closer spacing is recommended to increase the panel stiffness. Penerbit UMP 2011 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/14472/1/Bending%20Behavior%20of%20Semi-Continuous%20Prefabricated%20Profiled%20Steel.pdf Norhaiza, Nordin and Wan Hamidon, Wan Badaruzzaman and Nasly, Mohamed Ali and Wan Mansor, Wan Muhamad and Khairunisa, Muthusamy (2011) Bending Behavior of Semi-Continuous Prefabricated Profiled Steel Sheeting (PSSDB) Floor Panels. International Journal of Civil Engineering and Geo-Environmental, 2. pp. 1-5. ISSN 2180-2742 http://ijceg.ump.edu.my/images/ARTICLES/Vol.2/A1.pdf |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Norhaiza, Nordin Wan Hamidon, Wan Badaruzzaman Nasly, Mohamed Ali Wan Mansor, Wan Muhamad Khairunisa, Muthusamy Bending Behavior of Semi-Continuous Prefabricated Profiled Steel Sheeting (PSSDB) Floor Panels |
description |
Profiled Steel Sheeting Dry Board (PSSDB) floor panel is a composite of dry board and profiled steel sheeting screwed together by means of self-tapping, self-drilling shear connectors. The system has been successfully implemented in many Malaysian construction projects. Recently, the PSSDB system has been expanded to be an easy to assemble prefabricated floor for rural school cabin construction. An innovative prefabricated panel consists of three PSSDB parts which are then screwed together on site to form a semicontinuous panel has been proposed. This paper describes the three distinct parts of the panel, their assembly and the experiment to study the bending behavior of the panel. The semi-continuous panel performance was also compared to that of a continuous panel. All together, six 3.0 m span samples were tested under a uniformly distributed load until failure. The semi-continuous panels showed a two-phase behavior whilst the continuous panels showed a threephase behavior under loading which were related to the time of cracking of the dry board and the buckling of the profiled steel sheeting. The mid span deflections were recorded and used to determine the stiffness of the panels. Results showed that the stiffness of the semi-continuous panels were half of that of the continuous panels. It can be concluded that the discontinued spanning of the profiled steel sheeting has severely reduced the overall semicontinuous panel stiffness. The 25 screws used in the 0.6 m middle connecting panel had shown to be quite insufficient to hold the whole semi continuous panel together. Therefore, the addition of screws with closer spacing is recommended to increase the panel stiffness. |
format |
Article |
author |
Norhaiza, Nordin Wan Hamidon, Wan Badaruzzaman Nasly, Mohamed Ali Wan Mansor, Wan Muhamad Khairunisa, Muthusamy |
author_facet |
Norhaiza, Nordin Wan Hamidon, Wan Badaruzzaman Nasly, Mohamed Ali Wan Mansor, Wan Muhamad Khairunisa, Muthusamy |
author_sort |
Norhaiza, Nordin |
title |
Bending Behavior of Semi-Continuous Prefabricated Profiled Steel Sheeting (PSSDB) Floor Panels |
title_short |
Bending Behavior of Semi-Continuous Prefabricated Profiled Steel Sheeting (PSSDB) Floor Panels |
title_full |
Bending Behavior of Semi-Continuous Prefabricated Profiled Steel Sheeting (PSSDB) Floor Panels |
title_fullStr |
Bending Behavior of Semi-Continuous Prefabricated Profiled Steel Sheeting (PSSDB) Floor Panels |
title_full_unstemmed |
Bending Behavior of Semi-Continuous Prefabricated Profiled Steel Sheeting (PSSDB) Floor Panels |
title_sort |
bending behavior of semi-continuous prefabricated profiled steel sheeting (pssdb) floor panels |
publisher |
Penerbit UMP |
publishDate |
2011 |
url |
http://umpir.ump.edu.my/id/eprint/14472/ http://umpir.ump.edu.my/id/eprint/14472/ http://umpir.ump.edu.my/id/eprint/14472/1/Bending%20Behavior%20of%20Semi-Continuous%20Prefabricated%20Profiled%20Steel.pdf |
first_indexed |
2023-09-18T22:18:16Z |
last_indexed |
2023-09-18T22:18:16Z |
_version_ |
1777415483404845056 |