Indoor Microbial Contamination Through Water Mist Aerosol at Public Restaurants

In Malaysia and many other Asian countries, countless number of restaurants are made of open or semi-open air buildings. These restaurants are commonly located beside roads, factories, and construction sites. The foods are often exposed to the air, increasing their tendency to be contaminated due to...

Full description

Bibliographic Details
Main Authors: Maryam, Zahaba, Rafiqa Azira, M. R., Noor Faizul, Hadry, N. Norhidayah, A., Mohd Shukri, M. A.
Format: Article
Language:English
Published: Penerbit Universiti Teknologi Malaysia 2015
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/12357/
http://umpir.ump.edu.my/id/eprint/12357/
http://umpir.ump.edu.my/id/eprint/12357/1/Indoor%20Microbial%20Contamination%20Through%20Water%20Mist%20Aerosol%20at%20Public%20Restaurant.pdf
id ump-12357
recordtype eprints
spelling ump-123572016-03-22T07:40:22Z http://umpir.ump.edu.my/id/eprint/12357/ Indoor Microbial Contamination Through Water Mist Aerosol at Public Restaurants Maryam, Zahaba Rafiqa Azira, M. R. Noor Faizul, Hadry N. Norhidayah, A. Mohd Shukri, M. A. T Technology (General) In Malaysia and many other Asian countries, countless number of restaurants are made of open or semi-open air buildings. These restaurants are commonly located beside roads, factories, and construction sites. The foods are often exposed to the air, increasing their tendency to be contaminated due to poor indoor and outdoor air quality. There are very few studies characterising and comparing the levels of indoor air pollutants in restaurants. Other than that, scarce data are available on dining establishments especially in the presence and absence of water mist application system. Due to these reasons, no best practices or guidelines can be developed. Hence, this present study aimed (1) to assess and compare the physical indoor air quality (IAQ) characteristics and airborne pollutants between different types of restaurant settings; (2) to identify microbes isolated in the presence and absence of water mist system; (3) to analyse bacterial counting within and between the different restaurant settings; and (4) to determine the relationship between physical IAQ characteristics and airborne microbial contaminants. Instruments known as Dustmate and VelociCalcĀ® Multi-Function Ventilation Meter 9565 were used to measure the physical IAQ characteristics and airborne particulate matters. On the other hand, Surface Air System Indoor Air Quality (SAS IAQ) was use to seize the microbial contaminants. All the data obtained were compared with the standard reference known as the Industrial Code of Practice on Indoor Air Quality (2010) constructed by the Department of Occupational Safety and Health (DOSH). This study later indicated that the level of indoor PM10 concentrations was influenced by changes of physical IAQ parameters at the two restaurants investigated. As the PM10 increased, the colony forming unit (CFU) counting also increased. Although microbial contaminations were found during both periods of exposure (i.e., in the presence and absence of water mist) at both restaurants, significant relationship between the parameters measured cannot be determined. The bacterial species obtained during the presence and absence of water mist application system for both of the restaurants were also identified. Gemella morbillorum was found as the most dominant species, followed by other species such as Aerococcus viridans, Globicatella sanguinis, Leuconostoc spp., and Proteus penneri. Penerbit Universiti Teknologi Malaysia 2015 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/12357/1/Indoor%20Microbial%20Contamination%20Through%20Water%20Mist%20Aerosol%20at%20Public%20Restaurant.pdf Maryam, Zahaba and Rafiqa Azira, M. R. and Noor Faizul, Hadry and N. Norhidayah, A. and Mohd Shukri, M. A. (2015) Indoor Microbial Contamination Through Water Mist Aerosol at Public Restaurants. Jurnal Teknologi (Sciences and Engineering), 77 (24). pp. 45-50. ISSN 0127-9696 (print); 2180-3722 (online) http://www.jurnalteknologi.utm.my/index.php/jurnalteknologi/article/view/6706/4432
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic T Technology (General)
spellingShingle T Technology (General)
Maryam, Zahaba
Rafiqa Azira, M. R.
Noor Faizul, Hadry
N. Norhidayah, A.
Mohd Shukri, M. A.
Indoor Microbial Contamination Through Water Mist Aerosol at Public Restaurants
description In Malaysia and many other Asian countries, countless number of restaurants are made of open or semi-open air buildings. These restaurants are commonly located beside roads, factories, and construction sites. The foods are often exposed to the air, increasing their tendency to be contaminated due to poor indoor and outdoor air quality. There are very few studies characterising and comparing the levels of indoor air pollutants in restaurants. Other than that, scarce data are available on dining establishments especially in the presence and absence of water mist application system. Due to these reasons, no best practices or guidelines can be developed. Hence, this present study aimed (1) to assess and compare the physical indoor air quality (IAQ) characteristics and airborne pollutants between different types of restaurant settings; (2) to identify microbes isolated in the presence and absence of water mist system; (3) to analyse bacterial counting within and between the different restaurant settings; and (4) to determine the relationship between physical IAQ characteristics and airborne microbial contaminants. Instruments known as Dustmate and VelociCalcĀ® Multi-Function Ventilation Meter 9565 were used to measure the physical IAQ characteristics and airborne particulate matters. On the other hand, Surface Air System Indoor Air Quality (SAS IAQ) was use to seize the microbial contaminants. All the data obtained were compared with the standard reference known as the Industrial Code of Practice on Indoor Air Quality (2010) constructed by the Department of Occupational Safety and Health (DOSH). This study later indicated that the level of indoor PM10 concentrations was influenced by changes of physical IAQ parameters at the two restaurants investigated. As the PM10 increased, the colony forming unit (CFU) counting also increased. Although microbial contaminations were found during both periods of exposure (i.e., in the presence and absence of water mist) at both restaurants, significant relationship between the parameters measured cannot be determined. The bacterial species obtained during the presence and absence of water mist application system for both of the restaurants were also identified. Gemella morbillorum was found as the most dominant species, followed by other species such as Aerococcus viridans, Globicatella sanguinis, Leuconostoc spp., and Proteus penneri.
format Article
author Maryam, Zahaba
Rafiqa Azira, M. R.
Noor Faizul, Hadry
N. Norhidayah, A.
Mohd Shukri, M. A.
author_facet Maryam, Zahaba
Rafiqa Azira, M. R.
Noor Faizul, Hadry
N. Norhidayah, A.
Mohd Shukri, M. A.
author_sort Maryam, Zahaba
title Indoor Microbial Contamination Through Water Mist Aerosol at Public Restaurants
title_short Indoor Microbial Contamination Through Water Mist Aerosol at Public Restaurants
title_full Indoor Microbial Contamination Through Water Mist Aerosol at Public Restaurants
title_fullStr Indoor Microbial Contamination Through Water Mist Aerosol at Public Restaurants
title_full_unstemmed Indoor Microbial Contamination Through Water Mist Aerosol at Public Restaurants
title_sort indoor microbial contamination through water mist aerosol at public restaurants
publisher Penerbit Universiti Teknologi Malaysia
publishDate 2015
url http://umpir.ump.edu.my/id/eprint/12357/
http://umpir.ump.edu.my/id/eprint/12357/
http://umpir.ump.edu.my/id/eprint/12357/1/Indoor%20Microbial%20Contamination%20Through%20Water%20Mist%20Aerosol%20at%20Public%20Restaurant.pdf
first_indexed 2023-09-18T22:13:56Z
last_indexed 2023-09-18T22:13:56Z
_version_ 1777415211349704704