Build-up column is a steel structure composed of two I-beam steel joined with steel plate or angles as the lacings of the column. The build-up column is one of the main load carrying members among all the other structural components of a building. Since the build-up column is assembled manually at t...

Full description

Bibliographic Details
Main Author: Candra, Menan Nagappan
Format: Undergraduates Project Papers
Language:English
English
English
Published: 2015
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/12233/
http://umpir.ump.edu.my/id/eprint/12233/
http://umpir.ump.edu.my/id/eprint/12233/1/Finite%20element%20modelling%20analysis%20on%20built-up%20column%20-%20CHAP%201.pdf
http://umpir.ump.edu.my/id/eprint/12233/3/Finite%20element%20modelling%20analysis%20on%20built-up%20column%20-%20CHAP%203.pdf
http://umpir.ump.edu.my/id/eprint/12233/13/Finite%20element%20modelling%20analysis%20on%20built-up%20column%20-%2024%20pages.pdf
id ump-12233
recordtype eprints
spelling ump-122332016-11-15T01:57:37Z http://umpir.ump.edu.my/id/eprint/12233/ Finite element modelling analysis on built-up column Candra, Menan Nagappan TA Engineering (General). Civil engineering (General) Build-up column is a steel structure composed of two I-beam steel joined with steel plate or angles as the lacings of the column. The build-up column is one of the main load carrying members among all the other structural components of a building. Since the build-up column is assembled manually at the construction site, there might have some error in the section and orientation of the lacings assembled which will affect the performance of the build-up column. The main objectives of this study the effect of the different section and orientation of steel elements on build-up column in terms of buckling and stress distribution. Finite Element Analysis of Ansys 12.0 software is used to design the ten model of the build-up column. In order to study the effect of section of lacings, steel plate and L-angles are used. Besides that, to study the effect of orientation of the lacings, inclination angles of 40° , 45°, 50° , 55 ° and 60° are used. Based on the results, orientation of the steel lacings influenced the stress distribution of the due to the load. The greater the inclination angle the smaller the stress builds up on the lacings. Thus, the build-up column is more stable 2015-06 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/12233/1/Finite%20element%20modelling%20analysis%20on%20built-up%20column%20-%20CHAP%201.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/12233/3/Finite%20element%20modelling%20analysis%20on%20built-up%20column%20-%20CHAP%203.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/12233/13/Finite%20element%20modelling%20analysis%20on%20built-up%20column%20-%2024%20pages.pdf Candra, Menan Nagappan (2015) Finite element modelling analysis on built-up column. Faculty of Civil Engineering & Earth Resources, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:92245&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
English
English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Candra, Menan Nagappan
Finite element modelling analysis on built-up column
description Build-up column is a steel structure composed of two I-beam steel joined with steel plate or angles as the lacings of the column. The build-up column is one of the main load carrying members among all the other structural components of a building. Since the build-up column is assembled manually at the construction site, there might have some error in the section and orientation of the lacings assembled which will affect the performance of the build-up column. The main objectives of this study the effect of the different section and orientation of steel elements on build-up column in terms of buckling and stress distribution. Finite Element Analysis of Ansys 12.0 software is used to design the ten model of the build-up column. In order to study the effect of section of lacings, steel plate and L-angles are used. Besides that, to study the effect of orientation of the lacings, inclination angles of 40° , 45°, 50° , 55 ° and 60° are used. Based on the results, orientation of the steel lacings influenced the stress distribution of the due to the load. The greater the inclination angle the smaller the stress builds up on the lacings. Thus, the build-up column is more stable
format Undergraduates Project Papers
author Candra, Menan Nagappan
author_facet Candra, Menan Nagappan
author_sort Candra, Menan Nagappan
title Finite element modelling analysis on built-up column
title_short Finite element modelling analysis on built-up column
title_full Finite element modelling analysis on built-up column
title_fullStr Finite element modelling analysis on built-up column
title_full_unstemmed Finite element modelling analysis on built-up column
title_sort finite element modelling analysis on built-up column
publishDate 2015
url http://umpir.ump.edu.my/id/eprint/12233/
http://umpir.ump.edu.my/id/eprint/12233/
http://umpir.ump.edu.my/id/eprint/12233/1/Finite%20element%20modelling%20analysis%20on%20built-up%20column%20-%20CHAP%201.pdf
http://umpir.ump.edu.my/id/eprint/12233/3/Finite%20element%20modelling%20analysis%20on%20built-up%20column%20-%20CHAP%203.pdf
http://umpir.ump.edu.my/id/eprint/12233/13/Finite%20element%20modelling%20analysis%20on%20built-up%20column%20-%2024%20pages.pdf
first_indexed 2023-09-18T22:13:40Z
last_indexed 2023-09-18T22:13:40Z
_version_ 1777415194560954368