The effect of stent void area on hemodynamics in cerebral aneurysm
The purpose of this study is to develop modeling methodologies to understand how different stent void area alter the aneurysmal flow. Four difference stents design with difference void area were created with suitable geometry for Computational Fluid Dynamics (CFD) analysis. The velocity profile and...
Main Author: | |
---|---|
Format: | Undergraduates Project Papers |
Language: | English |
Published: |
2009
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/1116/ http://umpir.ump.edu.my/id/eprint/1116/ http://umpir.ump.edu.my/id/eprint/1116/1/Suriani_Abd_Rahman.pdf |
id |
ump-1116 |
---|---|
recordtype |
eprints |
spelling |
ump-11162015-03-03T07:48:52Z http://umpir.ump.edu.my/id/eprint/1116/ The effect of stent void area on hemodynamics in cerebral aneurysm Suriani, Abd Rahman TA Engineering (General). Civil engineering (General) The purpose of this study is to develop modeling methodologies to understand how different stent void area alter the aneurysmal flow. Four difference stents design with difference void area were created with suitable geometry for Computational Fluid Dynamics (CFD) analysis. The velocity profile and pressure distribution after installing the device had been identified from the selected stent. These four types of design will be referred as stent type I, II, III, and IV and these stent was tested in an aneurysm model. The simulation of the model was studied under incompressible, Newtonian, viscous, non pulsatile condition. In this study, we need to determine the correlation between stent porous area and blood flow and to determine the flow behavior in stented aneurysm. We found the stent design affected a cerebral aneurysm hemodynamic. The different of stent structural pattern produces the different results of flow field around the stented aneurysm. The minimum velocity had improved after stents insertion and the type IV with less void area results most optimized. Other than that, the peak pressure will also decrease after the stent implantation. As expected, the lowest peak pressure results from stent type IV. The result shows that the stent with the lowest void area gives the best performance. 2009-11 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/1116/1/Suriani_Abd_Rahman.pdf Suriani, Abd Rahman (2009) The effect of stent void area on hemodynamics in cerebral aneurysm. Faculty of Mechanical Engineering, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:45890&theme=UMP2 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Suriani, Abd Rahman The effect of stent void area on hemodynamics in cerebral aneurysm |
description |
The purpose of this study is to develop modeling methodologies to understand how different stent void area alter the aneurysmal flow. Four difference stents design with difference void area were created with suitable geometry for Computational Fluid Dynamics (CFD) analysis. The velocity profile and pressure distribution after installing the device had been identified from the selected stent. These four types of design will be referred as stent type I, II, III, and IV and these stent was tested in an aneurysm model. The simulation of the model was studied under incompressible, Newtonian, viscous, non pulsatile condition. In this study, we need to determine the correlation between stent porous area and blood flow and to determine the flow behavior in stented aneurysm. We found the stent design affected a cerebral aneurysm hemodynamic. The different of stent structural pattern produces the different results of flow field around the stented aneurysm. The minimum velocity had improved after stents insertion and the type IV with less void area results most optimized. Other than that, the peak pressure will also decrease after the stent implantation. As expected, the lowest peak pressure results from stent type IV. The result shows that the stent with the lowest void area gives the best performance. |
format |
Undergraduates Project Papers |
author |
Suriani, Abd Rahman |
author_facet |
Suriani, Abd Rahman |
author_sort |
Suriani, Abd Rahman |
title |
The effect of stent void area on hemodynamics in cerebral aneurysm |
title_short |
The effect of stent void area on hemodynamics in cerebral aneurysm |
title_full |
The effect of stent void area on hemodynamics in cerebral aneurysm |
title_fullStr |
The effect of stent void area on hemodynamics in cerebral aneurysm |
title_full_unstemmed |
The effect of stent void area on hemodynamics in cerebral aneurysm |
title_sort |
effect of stent void area on hemodynamics in cerebral aneurysm |
publishDate |
2009 |
url |
http://umpir.ump.edu.my/id/eprint/1116/ http://umpir.ump.edu.my/id/eprint/1116/ http://umpir.ump.edu.my/id/eprint/1116/1/Suriani_Abd_Rahman.pdf |
first_indexed |
2023-09-18T21:53:59Z |
last_indexed |
2023-09-18T21:53:59Z |
_version_ |
1777413955796336640 |