The Potential of Cooling Effect Using Palm Oil Clinker as Drainage Layer in Green Roof System
Research on green roof has been quite intensive in the past decade. Many researchers have studied on the cooling effect of green roof without focusing on an alternative to replace the conventional material in green roof system. The needs to use waste material become more essential to ensure the en...
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2015
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/10223/ http://umpir.ump.edu.my/id/eprint/10223/1/The%20Potential%20of%20Cooling%20Effect%20Using%20Palm%20Oil%20Clinker%20as%20Drainage%20Layer%20in%20Green%20Roof%20System.pdf |
id |
ump-10223 |
---|---|
recordtype |
eprints |
spelling |
ump-102232018-05-03T07:10:54Z http://umpir.ump.edu.my/id/eprint/10223/ The Potential of Cooling Effect Using Palm Oil Clinker as Drainage Layer in Green Roof System Khairul Anuar, Shahid Sharifah Maszura, Syed Mohsin Norhaiza, Ghazali TA Engineering (General). Civil engineering (General) Research on green roof has been quite intensive in the past decade. Many researchers have studied on the cooling effect of green roof without focusing on an alternative to replace the conventional material in green roof system. The needs to use waste material become more essential to ensure the environmental sustainability. Hence, this paper reports on the use of palm oil clinker as drainage layer in green roof system and also the cooling potential of green roof under Malaysia climatic condition. Hydraulic conductivity was investigated through constant load permeameter test and the cooling effect was studied by means of experimental green roof in cubicles. The analysis of thermal performance was carried out by using CLTD/CLF/SCL method. It was found that palm oil clinker is suitable to replace conventional materials as drainage layer in green roof system and it is also found that the green roof could reduce the air temperature inside the experimental cubicles hence reduced the heat gains 2015 Conference or Workshop Item PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/10223/1/The%20Potential%20of%20Cooling%20Effect%20Using%20Palm%20Oil%20Clinker%20as%20Drainage%20Layer%20in%20Green%20Roof%20System.pdf Khairul Anuar, Shahid and Sharifah Maszura, Syed Mohsin and Norhaiza, Ghazali (2015) The Potential of Cooling Effect Using Palm Oil Clinker as Drainage Layer in Green Roof System. In: Proceedings of Engineering Technology International Conference (ETIC 2015), 10-11 August 2015 , Bali, Indonesia. pp. 1-8.. |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Khairul Anuar, Shahid Sharifah Maszura, Syed Mohsin Norhaiza, Ghazali The Potential of Cooling Effect Using Palm Oil Clinker as Drainage Layer in Green Roof System |
description |
Research on green roof has been quite intensive in the past decade. Many researchers have studied on the cooling
effect of green roof without focusing on an alternative to replace the conventional material in green roof system. The
needs to use waste material become more essential to ensure the environmental sustainability. Hence, this paper
reports on the use of palm oil clinker as drainage layer in green roof system and also the cooling potential of green
roof under Malaysia climatic condition. Hydraulic conductivity was investigated through constant load permeameter test and the cooling effect was studied by means of experimental green roof in cubicles. The analysis of thermal performance was carried out by using CLTD/CLF/SCL method. It was found that palm oil clinker is suitable to replace conventional materials as drainage layer in green roof system and it is also found that the green roof could reduce the air temperature inside the experimental cubicles hence reduced the heat gains |
format |
Conference or Workshop Item |
author |
Khairul Anuar, Shahid Sharifah Maszura, Syed Mohsin Norhaiza, Ghazali |
author_facet |
Khairul Anuar, Shahid Sharifah Maszura, Syed Mohsin Norhaiza, Ghazali |
author_sort |
Khairul Anuar, Shahid |
title |
The Potential of Cooling Effect Using Palm Oil Clinker as Drainage Layer in Green Roof System |
title_short |
The Potential of Cooling Effect Using Palm Oil Clinker as Drainage Layer in Green Roof System |
title_full |
The Potential of Cooling Effect Using Palm Oil Clinker as Drainage Layer in Green Roof System |
title_fullStr |
The Potential of Cooling Effect Using Palm Oil Clinker as Drainage Layer in Green Roof System |
title_full_unstemmed |
The Potential of Cooling Effect Using Palm Oil Clinker as Drainage Layer in Green Roof System |
title_sort |
potential of cooling effect using palm oil clinker as drainage layer in green roof system |
publishDate |
2015 |
url |
http://umpir.ump.edu.my/id/eprint/10223/ http://umpir.ump.edu.my/id/eprint/10223/1/The%20Potential%20of%20Cooling%20Effect%20Using%20Palm%20Oil%20Clinker%20as%20Drainage%20Layer%20in%20Green%20Roof%20System.pdf |
first_indexed |
2023-09-18T22:09:36Z |
last_indexed |
2023-09-18T22:09:36Z |
_version_ |
1777414938895056896 |