Evaluating organ dose and radiation risk of routine CT examinations in Johor, Malaysia

In this study, radiation doses from CT scan procedures and its related risks to the patients from five hospitals in Johor State, Malaysia were analyzed. The survey was conducted in a two-month period encompassing data for 460 patients with the number for each hospital being set at 32, 30 and 30 samp...

Full description

Bibliographic Details
Main Authors: M.K.A. Karim, S. Hashim, A. Sabarudin, D.A. Bradley, N.A. Bahruddin
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2016
Online Access:http://journalarticle.ukm.my/9745/
http://journalarticle.ukm.my/9745/
http://journalarticle.ukm.my/9745/1/08_M.K.A_Karim.pdf
id ukm-9745
recordtype eprints
spelling ukm-97452016-12-14T06:50:43Z http://journalarticle.ukm.my/9745/ Evaluating organ dose and radiation risk of routine CT examinations in Johor, Malaysia M.K.A. Karim, S. Hashim, A. Sabarudin, D.A. Bradley, N.A. Bahruddin, In this study, radiation doses from CT scan procedures and its related risks to the patients from five hospitals in Johor State, Malaysia were analyzed. The survey was conducted in a two-month period encompassing data for 460 patients with the number for each hospital being set at 32, 30 and 30 samples for CT brain, CT thorax and CT abdomen, respectively. The results indicated that the CTDIw, DLP and effective dose values ranged from 7.0±1.3 to 67.7±3.4 mGy, 300.2±135.4 to 1174.2±79.9 mGy.cm and 1.5±0.2 to 11.7±6.65 mSv, respectively. The organ doses were calculated using CT EXPO software (Ver. 2.3.1, Germany) and were found to vary within the hospitals and the type of the CT examinations. Effective cancer risks per procedure were calculated by multiplying organ dose with the nominal cancer risk that was adapted from International Commission on Radiological Protection (ICRP) Publication 103. The values ranged from 0 to 1449 cancer cases per one million procedures for these three routine examinations. This present work showed that the CT systems can impart high radiation doses and increase of radiation risk to patients if optimization protocols are ignored. Penerbit Universiti Kebangsaan Malaysia 2016-04 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/9745/1/08_M.K.A_Karim.pdf M.K.A. Karim, and S. Hashim, and A. Sabarudin, and D.A. Bradley, and N.A. Bahruddin, (2016) Evaluating organ dose and radiation risk of routine CT examinations in Johor, Malaysia. Sains Malaysiana, 45 (4). pp. 567-573. ISSN 0126-6039 http://www.ukm.my/jsm/malay_journals/jilid45bil4_2016/KandunganJilid45Bil4_2016.htm
repository_type Digital Repository
institution_category Local University
institution Universiti Kebangasaan Malaysia
building UKM Institutional Repository
collection Online Access
language English
description In this study, radiation doses from CT scan procedures and its related risks to the patients from five hospitals in Johor State, Malaysia were analyzed. The survey was conducted in a two-month period encompassing data for 460 patients with the number for each hospital being set at 32, 30 and 30 samples for CT brain, CT thorax and CT abdomen, respectively. The results indicated that the CTDIw, DLP and effective dose values ranged from 7.0±1.3 to 67.7±3.4 mGy, 300.2±135.4 to 1174.2±79.9 mGy.cm and 1.5±0.2 to 11.7±6.65 mSv, respectively. The organ doses were calculated using CT EXPO software (Ver. 2.3.1, Germany) and were found to vary within the hospitals and the type of the CT examinations. Effective cancer risks per procedure were calculated by multiplying organ dose with the nominal cancer risk that was adapted from International Commission on Radiological Protection (ICRP) Publication 103. The values ranged from 0 to 1449 cancer cases per one million procedures for these three routine examinations. This present work showed that the CT systems can impart high radiation doses and increase of radiation risk to patients if optimization protocols are ignored.
format Article
author M.K.A. Karim,
S. Hashim,
A. Sabarudin,
D.A. Bradley,
N.A. Bahruddin,
spellingShingle M.K.A. Karim,
S. Hashim,
A. Sabarudin,
D.A. Bradley,
N.A. Bahruddin,
Evaluating organ dose and radiation risk of routine CT examinations in Johor, Malaysia
author_facet M.K.A. Karim,
S. Hashim,
A. Sabarudin,
D.A. Bradley,
N.A. Bahruddin,
author_sort M.K.A. Karim,
title Evaluating organ dose and radiation risk of routine CT examinations in Johor, Malaysia
title_short Evaluating organ dose and radiation risk of routine CT examinations in Johor, Malaysia
title_full Evaluating organ dose and radiation risk of routine CT examinations in Johor, Malaysia
title_fullStr Evaluating organ dose and radiation risk of routine CT examinations in Johor, Malaysia
title_full_unstemmed Evaluating organ dose and radiation risk of routine CT examinations in Johor, Malaysia
title_sort evaluating organ dose and radiation risk of routine ct examinations in johor, malaysia
publisher Penerbit Universiti Kebangsaan Malaysia
publishDate 2016
url http://journalarticle.ukm.my/9745/
http://journalarticle.ukm.my/9745/
http://journalarticle.ukm.my/9745/1/08_M.K.A_Karim.pdf
first_indexed 2023-09-18T19:55:35Z
last_indexed 2023-09-18T19:55:35Z
_version_ 1777406506933682176