Determination of peak- to-total ratio versus gamma-ray energy of a HPGe detector
This note describes a method for the determination of the peak-to-total ratio, P/T versus gamma-ray energy of range 59.54-1836.03 keV of a HPGe detector. Results show that this ratio decreases with energy. To check the validity of these results, two approaches of results comparison, namely with the...
Main Authors: | , |
---|---|
Format: | Article |
Published: |
Universiti Kebangsaan Malaysia
2006
|
Online Access: | http://journalarticle.ukm.my/3975/ http://journalarticle.ukm.my/3975/ |
id |
ukm-3975 |
---|---|
recordtype |
eprints |
spelling |
ukm-39752012-03-28T01:02:46Z http://journalarticle.ukm.my/3975/ Determination of peak- to-total ratio versus gamma-ray energy of a HPGe detector Supian Samat , Lee , Yuen Kong This note describes a method for the determination of the peak-to-total ratio, P/T versus gamma-ray energy of range 59.54-1836.03 keV of a HPGe detector. Results show that this ratio decreases with energy. To check the validity of these results, two approaches of results comparison, namely with the ratio reported by Cesana and Terrani in year 1989 and with the shape of total efficiency reported by Debertin and Helmer in year 1988 were taken. lt is shown that this method gives satisfactory results since the obtained values of P/T and the shape of the total efficiency curve were in good agreement with the reported works. The precautional step that need to be taken when dealing with energy 59.54 keV 241Am source and the reason for taking the total efficiency as the evaluation tool are given. Universiti Kebangsaan Malaysia 2006-07 Article PeerReviewed Supian Samat , and Lee , Yuen Kong (2006) Determination of peak- to-total ratio versus gamma-ray energy of a HPGe detector. Sains Malaysiana, 35 (1). pp. 57-60. ISSN 0126-6039 http://www.ukm.my/jsm/english_journals/vol35num1_2006/vol35num1_06page57-60.html |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Kebangasaan Malaysia |
building |
UKM Institutional Repository |
collection |
Online Access |
description |
This note describes a method for the determination of the peak-to-total ratio, P/T versus gamma-ray energy of range 59.54-1836.03 keV of a HPGe detector. Results show that this ratio decreases with energy. To check the validity of these results, two approaches of results comparison, namely with the ratio reported by Cesana and Terrani in year 1989 and with the shape of total efficiency reported by Debertin and Helmer in year 1988 were taken. lt is shown that this method gives satisfactory results since the obtained values of P/T and the shape of the total efficiency curve were in good agreement with the reported works. The precautional step that need to be taken when dealing with energy 59.54 keV 241Am source and the reason for taking the total efficiency as the evaluation tool are given. |
format |
Article |
author |
Supian Samat , Lee , Yuen Kong |
spellingShingle |
Supian Samat , Lee , Yuen Kong Determination of peak- to-total ratio versus gamma-ray energy of a HPGe detector |
author_facet |
Supian Samat , Lee , Yuen Kong |
author_sort |
Supian Samat , |
title |
Determination of peak- to-total ratio versus gamma-ray energy of a HPGe detector |
title_short |
Determination of peak- to-total ratio versus gamma-ray energy of a HPGe detector |
title_full |
Determination of peak- to-total ratio versus gamma-ray energy of a HPGe detector |
title_fullStr |
Determination of peak- to-total ratio versus gamma-ray energy of a HPGe detector |
title_full_unstemmed |
Determination of peak- to-total ratio versus gamma-ray energy of a HPGe detector |
title_sort |
determination of peak- to-total ratio versus gamma-ray energy of a hpge detector |
publisher |
Universiti Kebangsaan Malaysia |
publishDate |
2006 |
url |
http://journalarticle.ukm.my/3975/ http://journalarticle.ukm.my/3975/ |
first_indexed |
2023-09-18T19:40:18Z |
last_indexed |
2023-09-18T19:40:18Z |
_version_ |
1777405545001517056 |