Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique

It is common to use motorised and non-motorised treadmills in settings with space constraints for a 6-minute walk test (6MWT). This test used manual methods which are susceptible to errors. It is believed that automated techniques could eliminate the shortcomings, but this approach was not proposed...

Full description

Bibliographic Details
Main Authors: Isniza Ismail, Leela T. Narayanan, Rumaisa Abu Hasan, Eko Supriyanto
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2019
Online Access:http://journalarticle.ukm.my/14397/
http://journalarticle.ukm.my/14397/
http://journalarticle.ukm.my/14397/1/16%20Isniza%20Ismail.pdf
id ukm-14397
recordtype eprints
spelling ukm-143972020-03-10T02:31:44Z http://journalarticle.ukm.my/14397/ Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique Isniza Ismail, Leela T. Narayanan, Rumaisa Abu Hasan, Eko Supriyanto, It is common to use motorised and non-motorised treadmills in settings with space constraints for a 6-minute walk test (6MWT). This test used manual methods which are susceptible to errors. It is believed that automated techniques could eliminate the shortcomings, but this approach was not proposed by any studies. This study presented and analysed the validity of a newly-developed automated infrared-based treadmill walking monitoring system (iTMS), which as specifically designed to measure the distance and characteristics for the walk performance of a non-motorised treadmill 6MWT (nMT6MWT). This study selected 20 subjects for: The validity testing of the iTMS walked distance at five different speeds dictated by metronome beats for 2-minute and at a self-paced speed with intermittent rests for 6-minute, and the characterisation of 6-minute walk performance for distance, speed, acceleration, walking segments, and resting events. The iTMS measured distances were consistently accurate for the varying speeds during the 2-minute walk session. For the 6-minute walk en bloc and its three segments, the difference in distance (Δd) between iTMS (diTMS) and camera recording method (dCRM) showed positive biases with small LOA95% in Bland-Altman plot. The iTMS has an accurate distance measurement with ± 0.20% error of dCRM for en bloc 6-minute walk can characterise the resting events of 0.5 s and more. The iTMS is considered a viable automated method for monitoring distance and characterising nMT6MWT. It also showed the potential in addressing technical errors which may be inherent in manual 6MWT data collection methods. Penerbit Universiti Kebangsaan Malaysia 2019-10 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/14397/1/16%20Isniza%20Ismail.pdf Isniza Ismail, and Leela T. Narayanan, and Rumaisa Abu Hasan, and Eko Supriyanto, (2019) Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique. Sains Malaysiana, 48 (10). pp. 2201-2209. ISSN 0126-6039 http://www.ukm.my/jsm/malay_journals/jilid48bil10_2019/KandunganJilid48Bil10_2019.htm
repository_type Digital Repository
institution_category Local University
institution Universiti Kebangasaan Malaysia
building UKM Institutional Repository
collection Online Access
language English
description It is common to use motorised and non-motorised treadmills in settings with space constraints for a 6-minute walk test (6MWT). This test used manual methods which are susceptible to errors. It is believed that automated techniques could eliminate the shortcomings, but this approach was not proposed by any studies. This study presented and analysed the validity of a newly-developed automated infrared-based treadmill walking monitoring system (iTMS), which as specifically designed to measure the distance and characteristics for the walk performance of a non-motorised treadmill 6MWT (nMT6MWT). This study selected 20 subjects for: The validity testing of the iTMS walked distance at five different speeds dictated by metronome beats for 2-minute and at a self-paced speed with intermittent rests for 6-minute, and the characterisation of 6-minute walk performance for distance, speed, acceleration, walking segments, and resting events. The iTMS measured distances were consistently accurate for the varying speeds during the 2-minute walk session. For the 6-minute walk en bloc and its three segments, the difference in distance (Δd) between iTMS (diTMS) and camera recording method (dCRM) showed positive biases with small LOA95% in Bland-Altman plot. The iTMS has an accurate distance measurement with ± 0.20% error of dCRM for en bloc 6-minute walk can characterise the resting events of 0.5 s and more. The iTMS is considered a viable automated method for monitoring distance and characterising nMT6MWT. It also showed the potential in addressing technical errors which may be inherent in manual 6MWT data collection methods.
format Article
author Isniza Ismail,
Leela T. Narayanan,
Rumaisa Abu Hasan,
Eko Supriyanto,
spellingShingle Isniza Ismail,
Leela T. Narayanan,
Rumaisa Abu Hasan,
Eko Supriyanto,
Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique
author_facet Isniza Ismail,
Leela T. Narayanan,
Rumaisa Abu Hasan,
Eko Supriyanto,
author_sort Isniza Ismail,
title Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique
title_short Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique
title_full Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique
title_fullStr Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique
title_full_unstemmed Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique
title_sort automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique
publisher Penerbit Universiti Kebangsaan Malaysia
publishDate 2019
url http://journalarticle.ukm.my/14397/
http://journalarticle.ukm.my/14397/
http://journalarticle.ukm.my/14397/1/16%20Isniza%20Ismail.pdf
first_indexed 2023-09-18T20:06:59Z
last_indexed 2023-09-18T20:06:59Z
_version_ 1777407223983505408