Artificial intelligence based Technique for prediction of partial discharge inception Voltage in a void of solid dielectric / Siti Salwani Samat

Partial discharge (PD) is an important issue since it is considered as one of the greatest threats to insulation system of high voltage equipment. Existence of PD signifies that there is a weak point in an electrical insulation system and the existence of PD not only indicates that electrical...

Full description

Bibliographic Details
Main Author: Samat, Siti Salwani
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/25822/
http://ir.uitm.edu.my/id/eprint/25822/1/TM_SITI%20SALWANI%20SAMAT%20EE%2014_5.pdf
id uitm-25822
recordtype eprints
spelling uitm-258222019-09-26T08:49:10Z http://ir.uitm.edu.my/id/eprint/25822/ Artificial intelligence based Technique for prediction of partial discharge inception Voltage in a void of solid dielectric / Siti Salwani Samat Samat, Siti Salwani Devices for production of electricity by direct energy conversion Dielectric devices Partial discharge (PD) is an important issue since it is considered as one of the greatest threats to insulation system of high voltage equipment. Existence of PD signifies that there is a weak point in an electrical insulation system and the existence of PD not only indicates that electrical aging is occurring, but also mechanical, thermal or environmental aging processes may be present. Materials such as solid, liquid and gaseous that are used for insulation purpose are imperfect and always contaminated. Most of the solid insulation has impurity in the form of air bubbles (void) which created a small fragile zone in the insulator during the manufacturing process and is a common source of PD. Due to the void, the insulation region is weakens resulting in the appearance of PDs with the application of high voltage. On the other hand, partial discharge inception voltage (PDIV) or also known as the breakdown voltage is the lowest voltage at which the PD events are detected. The PDIV due to PD in a void is a random phenomenon. The designing of an insulation system depends critically on the magnitude of this voltage. It is crucial to comprehend the property of the insulating materials for optimal solution in terms of insulating ability and costing. Therefore, accurate PD and PDIV models with the presence of void are highly needed to develop solid insulating materials with high breakdown strength. Lacking of these PD models will lead to difficulties in understanding the PD behavior and characteristics. As a result, assessing the insulation condition becomes a complicated process. In addition to that, an accurate artificial neural network (ANN) PD prediction system shall be the solution to help the electrical engineers in general and high voltage engineers particularly to develop a high quality insulation material that is more reliable and cost effective. This thesis presents an artificial intelligence based technique for partial discharge inception voltage (PDIV) prediction in a void of solid dielectric. This study involves the development of a MATLAB Simulink model for single void of solid dielectric for PD characterization. It also involves the development of hybrid ANN evolutionary programming (EP) for the prediction of PDIV of solid dielectric of different sizes of void. This study has also implemented an optimization technique using EP to improve the accuracy of the prediction system by finding an optimal number of learning rate and momentum constant. EP is an express search technique that is widely chosen to simplify the calculation process and also to fine tuning the result. The result of simulations has proven that the input signals such as supply voltage and supply voltage frequency are important for PD characterization. Comparative studies were done in term of the accuracy of the prediction system that was evaluated by the value of correlation coefficient, R. The result showed that the optimized ANN has able to produce a high value of R near to unity and the error was reduced tremendously. The convergence and generalization ability of the combined ANN-EP has improved outstandingly with the optimization process. 2014 Thesis NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/25822/1/TM_SITI%20SALWANI%20SAMAT%20EE%2014_5.pdf Samat, Siti Salwani (2014) Artificial intelligence based Technique for prediction of partial discharge inception Voltage in a void of solid dielectric / Siti Salwani Samat. Masters thesis, Universiti Teknologi MARA.
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
topic Devices for production of electricity by direct energy conversion
Dielectric devices
spellingShingle Devices for production of electricity by direct energy conversion
Dielectric devices
Samat, Siti Salwani
Artificial intelligence based Technique for prediction of partial discharge inception Voltage in a void of solid dielectric / Siti Salwani Samat
description Partial discharge (PD) is an important issue since it is considered as one of the greatest threats to insulation system of high voltage equipment. Existence of PD signifies that there is a weak point in an electrical insulation system and the existence of PD not only indicates that electrical aging is occurring, but also mechanical, thermal or environmental aging processes may be present. Materials such as solid, liquid and gaseous that are used for insulation purpose are imperfect and always contaminated. Most of the solid insulation has impurity in the form of air bubbles (void) which created a small fragile zone in the insulator during the manufacturing process and is a common source of PD. Due to the void, the insulation region is weakens resulting in the appearance of PDs with the application of high voltage. On the other hand, partial discharge inception voltage (PDIV) or also known as the breakdown voltage is the lowest voltage at which the PD events are detected. The PDIV due to PD in a void is a random phenomenon. The designing of an insulation system depends critically on the magnitude of this voltage. It is crucial to comprehend the property of the insulating materials for optimal solution in terms of insulating ability and costing. Therefore, accurate PD and PDIV models with the presence of void are highly needed to develop solid insulating materials with high breakdown strength. Lacking of these PD models will lead to difficulties in understanding the PD behavior and characteristics. As a result, assessing the insulation condition becomes a complicated process. In addition to that, an accurate artificial neural network (ANN) PD prediction system shall be the solution to help the electrical engineers in general and high voltage engineers particularly to develop a high quality insulation material that is more reliable and cost effective. This thesis presents an artificial intelligence based technique for partial discharge inception voltage (PDIV) prediction in a void of solid dielectric. This study involves the development of a MATLAB Simulink model for single void of solid dielectric for PD characterization. It also involves the development of hybrid ANN evolutionary programming (EP) for the prediction of PDIV of solid dielectric of different sizes of void. This study has also implemented an optimization technique using EP to improve the accuracy of the prediction system by finding an optimal number of learning rate and momentum constant. EP is an express search technique that is widely chosen to simplify the calculation process and also to fine tuning the result. The result of simulations has proven that the input signals such as supply voltage and supply voltage frequency are important for PD characterization. Comparative studies were done in term of the accuracy of the prediction system that was evaluated by the value of correlation coefficient, R. The result showed that the optimized ANN has able to produce a high value of R near to unity and the error was reduced tremendously. The convergence and generalization ability of the combined ANN-EP has improved outstandingly with the optimization process.
format Thesis
author Samat, Siti Salwani
author_facet Samat, Siti Salwani
author_sort Samat, Siti Salwani
title Artificial intelligence based Technique for prediction of partial discharge inception Voltage in a void of solid dielectric / Siti Salwani Samat
title_short Artificial intelligence based Technique for prediction of partial discharge inception Voltage in a void of solid dielectric / Siti Salwani Samat
title_full Artificial intelligence based Technique for prediction of partial discharge inception Voltage in a void of solid dielectric / Siti Salwani Samat
title_fullStr Artificial intelligence based Technique for prediction of partial discharge inception Voltage in a void of solid dielectric / Siti Salwani Samat
title_full_unstemmed Artificial intelligence based Technique for prediction of partial discharge inception Voltage in a void of solid dielectric / Siti Salwani Samat
title_sort artificial intelligence based technique for prediction of partial discharge inception voltage in a void of solid dielectric / siti salwani samat
publishDate 2014
url http://ir.uitm.edu.my/id/eprint/25822/
http://ir.uitm.edu.my/id/eprint/25822/1/TM_SITI%20SALWANI%20SAMAT%20EE%2014_5.pdf
first_indexed 2023-09-18T23:15:34Z
last_indexed 2023-09-18T23:15:34Z
_version_ 1777419088415424512