Analysis of lead in infant milk formula by differential pulse anodic stripping voltammetric technique / Nurhanis Zainol Abidin
Most of dairy products especially milk are very popular all over the world as a daily consumed by human as the nutritional balance food and has major sources of the nutrients especially for infant in the first six months of life. It is very important to determine the level of Pb content in infant...
Main Author: | |
---|---|
Format: | Student Project |
Language: | English |
Published: |
Faculty Of Applied Sciences
2016
|
Subjects: | |
Online Access: | http://ir.uitm.edu.my/id/eprint/23131/ http://ir.uitm.edu.my/id/eprint/23131/1/PPb_NURHANIS%20ZAINOL%20ABIDIN%20AS%20C%2016_5.PDF |
id |
uitm-23131 |
---|---|
recordtype |
eprints |
spelling |
uitm-231312019-02-25T07:02:06Z http://ir.uitm.edu.my/id/eprint/23131/ Analysis of lead in infant milk formula by differential pulse anodic stripping voltammetric technique / Nurhanis Zainol Abidin Zainol Abidin, Nurhanis Analytical chemistry Most of dairy products especially milk are very popular all over the world as a daily consumed by human as the nutritional balance food and has major sources of the nutrients especially for infant in the first six months of life. It is very important to determine the level of Pb content in infant milk formula either it is permissible to be consumed or not for the safety and quality purposed as it is neurotoxin for infants, reduces IQ, disables learning abilities and affects nervous system development. According to EC Regulation 446/2001, the limit of Pb in the infant milk formula is 20 ug/L. The differential pulse anodic stripping voltammetric (DPASV) technique using glassy carbon electrode (GCE) as a working electrode and acetate buffer at pH 4.6 as a supporting electrolyte has been proposed to be developed. The experimental voltammetric parameters were optimized in order to obtain a maximum response with analytical validation of the technique. The optimum parameters were initial potential (Ei) =-1.0 V, end potential (Ef) = -0.2 V, scan rate (v) = 0.04 VIs, accumulation time (tacc) = 90 s, accumulation potential (Eacc) == -1.0 V and pulse amplitude = 0.075 V. The anodic peak was appeared at -0.5603 V. The curve was linear from 0.05 to 1.0 Mg/L (R2=0.09992) with detection limit of 10 ug/L. The precisions in terms of relative standard deviation (RSD) were 4.28%, 2.82% and 0.78% for consecutive three days. The satisfactory recoveries obtained were from 79.26 to 87.75% and 94.72 to 98.88% for respective 0.5 and 1.0 mg/L Pb standard solution in the pre-treated infant milk formula samples. It can be concluded that the developed technique is precise, accurate, rugged, robust, low cost, fast and has potential to be an alternative method for routine analysis of Pb in the infant milk formula. Faculty Of Applied Sciences 2016 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/23131/1/PPb_NURHANIS%20ZAINOL%20ABIDIN%20AS%20C%2016_5.PDF Zainol Abidin, Nurhanis (2016) Analysis of lead in infant milk formula by differential pulse anodic stripping voltammetric technique / Nurhanis Zainol Abidin. [Student Project] (Unpublished) |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Teknologi MARA |
building |
UiTM Institutional Repository |
collection |
Online Access |
language |
English |
topic |
Analytical chemistry |
spellingShingle |
Analytical chemistry Zainol Abidin, Nurhanis Analysis of lead in infant milk formula by differential pulse anodic stripping voltammetric technique / Nurhanis Zainol Abidin |
description |
Most of dairy products especially milk are very popular all over the world as a daily
consumed by human as the nutritional balance food and has major sources of the
nutrients especially for infant in the first six months of life. It is very important to
determine the level of Pb content in infant milk formula either it is permissible to be
consumed or not for the safety and quality purposed as it is neurotoxin for infants,
reduces IQ, disables learning abilities and affects nervous system development.
According to EC Regulation 446/2001, the limit of Pb in the infant milk formula is 20
ug/L. The differential pulse anodic stripping voltammetric (DPASV) technique using
glassy carbon electrode (GCE) as a working electrode and acetate buffer at pH 4.6 as
a supporting electrolyte has been proposed to be developed. The experimental
voltammetric parameters were optimized in order to obtain a maximum response with
analytical validation of the technique. The optimum parameters were initial potential
(Ei) =-1.0 V, end potential (Ef) = -0.2 V, scan rate (v) = 0.04 VIs, accumulation time
(tacc) = 90 s, accumulation potential (Eacc) == -1.0 V and pulse amplitude = 0.075 V.
The anodic peak was appeared at -0.5603 V. The curve was linear from 0.05 to 1.0
Mg/L (R2=0.09992) with detection limit of 10 ug/L. The precisions in terms of relative
standard deviation (RSD) were 4.28%, 2.82% and 0.78% for consecutive three days.
The satisfactory recoveries obtained were from 79.26 to 87.75% and 94.72 to 98.88%
for respective 0.5 and 1.0 mg/L Pb standard solution in the pre-treated infant milk
formula samples. It can be concluded that the developed technique is precise, accurate,
rugged, robust, low cost, fast and has potential to be an alternative method for routine
analysis of Pb in the infant milk formula. |
format |
Student Project |
author |
Zainol Abidin, Nurhanis |
author_facet |
Zainol Abidin, Nurhanis |
author_sort |
Zainol Abidin, Nurhanis |
title |
Analysis of lead in infant milk formula by differential pulse anodic stripping voltammetric
technique / Nurhanis Zainol Abidin |
title_short |
Analysis of lead in infant milk formula by differential pulse anodic stripping voltammetric
technique / Nurhanis Zainol Abidin |
title_full |
Analysis of lead in infant milk formula by differential pulse anodic stripping voltammetric
technique / Nurhanis Zainol Abidin |
title_fullStr |
Analysis of lead in infant milk formula by differential pulse anodic stripping voltammetric
technique / Nurhanis Zainol Abidin |
title_full_unstemmed |
Analysis of lead in infant milk formula by differential pulse anodic stripping voltammetric
technique / Nurhanis Zainol Abidin |
title_sort |
analysis of lead in infant milk formula by differential pulse anodic stripping voltammetric
technique / nurhanis zainol abidin |
publisher |
Faculty Of Applied Sciences |
publishDate |
2016 |
url |
http://ir.uitm.edu.my/id/eprint/23131/ http://ir.uitm.edu.my/id/eprint/23131/1/PPb_NURHANIS%20ZAINOL%20ABIDIN%20AS%20C%2016_5.PDF |
first_indexed |
2023-09-18T23:10:07Z |
last_indexed |
2023-09-18T23:10:07Z |
_version_ |
1777418746470596608 |