Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil

In this study, treated sewage sludge from Indah Water Pantai Dalam and Kolej Mawar waste water treatment plant were characterized for pyrolysis application to generate product oil for bio-fuel. The characterization analyses of sample were carried out according to the American Test Method (ASTM). Bas...

Full description

Bibliographic Details
Main Author: Md Tawil, Mohd Faizal
Format: Student Project
Language:English
Published: Faculty of Applied Sciences 2009
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/23099/
http://ir.uitm.edu.my/id/eprint/23099/1/PPb_MOHD%20FAIZAL%20MD%20TAWIL%20AS%2009_5.pdf
id uitm-23099
recordtype eprints
spelling uitm-230992019-02-27T07:39:15Z http://ir.uitm.edu.my/id/eprint/23099/ Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil Md Tawil, Mohd Faizal Sewage collection and disposal systems. Sewerage Sewage sludge In this study, treated sewage sludge from Indah Water Pantai Dalam and Kolej Mawar waste water treatment plant were characterized for pyrolysis application to generate product oil for bio-fuel. The characterization analyses of sample were carried out according to the American Test Method (ASTM). Based on the proximate and ultimate analysis data, both samples has a calorific value around 11±1 MJ/kg, ash content lower than volatile matter and low fixed carbon value, where sample from IWK Pantai Dalam was has the higher volatile matter and lowest ash content. Previous research was concluding that high volatile matter content with low ash content was the main criteria for pyrolysis. Based upon the fact, the pyrolysis of sample from IWK Pantai Dalam was performed in a flash pyrolysis reactor with four difference temperature 400°C, 500°C, 600°C, and 650°C. At temperature of 600°C the liquid oil yield was maximum (28.48 wt %) and afterwards began to decline. The liquid oil produce is alkali solution with high density and valuable calorific value. The liquid oil obtained at temperature 600°C was analyzed for its chemical compound by using FTIR and GCMS. Result showed that liquid oil contain a high proportion of alkane, alkene, and aromatic compounds that would be interesting in order to use the bio-oil in bio-fuel applications. Faculty of Applied Sciences 2009 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/23099/1/PPb_MOHD%20FAIZAL%20MD%20TAWIL%20AS%2009_5.pdf Md Tawil, Mohd Faizal (2009) Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil. [Student Project] (Unpublished)
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
topic Sewage collection and disposal systems. Sewerage
Sewage sludge
spellingShingle Sewage collection and disposal systems. Sewerage
Sewage sludge
Md Tawil, Mohd Faizal
Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil
description In this study, treated sewage sludge from Indah Water Pantai Dalam and Kolej Mawar waste water treatment plant were characterized for pyrolysis application to generate product oil for bio-fuel. The characterization analyses of sample were carried out according to the American Test Method (ASTM). Based on the proximate and ultimate analysis data, both samples has a calorific value around 11±1 MJ/kg, ash content lower than volatile matter and low fixed carbon value, where sample from IWK Pantai Dalam was has the higher volatile matter and lowest ash content. Previous research was concluding that high volatile matter content with low ash content was the main criteria for pyrolysis. Based upon the fact, the pyrolysis of sample from IWK Pantai Dalam was performed in a flash pyrolysis reactor with four difference temperature 400°C, 500°C, 600°C, and 650°C. At temperature of 600°C the liquid oil yield was maximum (28.48 wt %) and afterwards began to decline. The liquid oil produce is alkali solution with high density and valuable calorific value. The liquid oil obtained at temperature 600°C was analyzed for its chemical compound by using FTIR and GCMS. Result showed that liquid oil contain a high proportion of alkane, alkene, and aromatic compounds that would be interesting in order to use the bio-oil in bio-fuel applications.
format Student Project
author Md Tawil, Mohd Faizal
author_facet Md Tawil, Mohd Faizal
author_sort Md Tawil, Mohd Faizal
title Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil
title_short Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil
title_full Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil
title_fullStr Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil
title_full_unstemmed Sewage sludge characterization and pyrolysis / Mohd Faizal Md Tawil
title_sort sewage sludge characterization and pyrolysis / mohd faizal md tawil
publisher Faculty of Applied Sciences
publishDate 2009
url http://ir.uitm.edu.my/id/eprint/23099/
http://ir.uitm.edu.my/id/eprint/23099/1/PPb_MOHD%20FAIZAL%20MD%20TAWIL%20AS%2009_5.pdf
first_indexed 2023-09-18T23:10:03Z
last_indexed 2023-09-18T23:10:03Z
_version_ 1777418741788704768